Anwendungshinweisen
Borescope inspection of helicopter main gear boxes
Main gearbox (in the red box in the picture above)
Application—Borescope inspection of helicopter main gear boxes
During routine helicopter maintenance, inspectors use borescopes to check for any breakage or cracks in the gear or gear carrier of the main . The main (MGB) is the mechanism that transmits power from the engine to the main rotor. The MGB consists of multiple components, including a gear carrier and planet gears that are driven by the power from the engine. If the tip of the borescope comes into contact with these components during the inspection, the gear oil lubricating their surfaces can become attached to the objective lens, obstructing the view and reducing visibility for inspectors.
Solution Using IPLEX Industrial Videoscope Accessories
To help resolve the issue of impaired visibility caused by gear oil on borescope lenses during MGB inspection, Olympus offers two accessories for IPLEX series videoscopes—one that helps prevent the problem, and one that facilitates oil removal:
Oil cleaning tip adaptor
Olympus’ forward-viewing adaptor for IPLEX series videoscopes has a special capillary-activated design that helps remove oil that attaches to the surface of the objective lens. This oil clearing tip adaptor enables inspectors to continue the inspection without having to stop, withdraw the scope, and clean the lens (only compatible with certain IPLEX models.)
Oil clearing adaptor for IPLEX videoscopes
Rigid sleeve
By using the rigid sleeve, another IPLEX videoscope accessory, you can help prevent accidental contact between the tip of the scope and the inspected object. can help reduce the risk for gear oil attachment. The rigid sleeve also facilitates inserting the scope deep into the back of the , effectively expanding the range of inspection.
Rigid sleeve
Conclusion
Using Olympus IPLEX industrial videoscopes can help alleviate a common problem in inspecting main of helicopters: poor visibility caused by gear oil obstruction. Using the oil clearing tip adaptor and rigid sleeve improve the efficiency and ease of this borescope inspection application, helping to ensure the safe and efficient operation of helicopters.
Verwandte Produkte
IPLEX NX
Ein hochwertiges Videoskopsystem für die Industrie, das Transportfähigkeit mit modernsten Funktionen und Bedienerfreundlichkeit mit Haltbarkeit kombiniert. Von Prüfungen mit hoher Bildqualität bis hin zum Abrufvorgang ermöglicht die Vielseitigkeit dieses Videoskops bisher ungeahnte Vorteile.
IPLEX G Lite/G Lite-W
Das IPLEX G Lite Industrie-Videoskop vereint eine Vielzahl leistungsstarker Bildgebungsfunktionen in einem kleinen, robusten Gehäuse. Leicht und überall mit hinnehmbar – damit haben Prüfer ein Tool für Sichtprüfungen für komplexe Anwendungen von hoher Bildqualität und Bedienerfreundlichkeit, die die Arbeit unterstützt.
Das portable IPLEX G Lite Videoskopmodell für Windkraftanlagen eignet sich mit seinen leistungsstarken Bildgebungsfunktionen für die Prüfung in Gondeln von Windkraftanlagen bei beengtem Platz und kann die Arbeit erleichtern.