3D Evaluation of Automobile Door Switch Embossing Using the LEXT OLS5000 Laser Microscope

Micro-sized measurement using a laser microscope

Automobile switch covers
Automobile switch covers

(1) Application

Embossing on the surface of dashboards, seats, door trim, and other interior components of automobiles contribute to the product’s aesthetic value and influence the satisfaction of car buyers.

Door switch buttons are one of these aesthetic components, and the material, texture, and color of the buttons in proportion to the surrounding door trim has a significant influence on the value of the overall product. Although the emotional impression derived from perceived differences is important, automobile manufacturers require a quantitative evaluation.

(2) Evident' solution

The texture of the embossing on door swtiches can be evaluated using Evident' LEXT OLS5000(Formerly Olympus LEXT OLS5000) 3D scanning laser microscope, which is capable of high-resolution and high-precision 3D data display and surface roughness analysis. The LEXT OLS5000 microscope’s laser optical system is a noncontact type, yet it provides the same roughness (two-dimensional) parameters as contact-type microscopes and produces compatible results. The OLS5000 microscope also provides three-dimensional roughness parameters that comply with ISO25178, enabling you to obtain more information than mere line roughness through surface-area evaluation using 3D images and numerical data. High resolution data can be acquired for multiple points on the surface by saving measurement coordinates in Stitching mode, increasing the field of view exponentially.

Images

(1) Sample A (20X objective, 3×3 stitching of 640 µm2 points for an effective field of vision: 1800 µm2)

Measurement point 1

Measurement point 1

Measurement point 2

Measurement point 2

Measurement point 3

Measurement point 3

Parameter
Sq [µm]
Sa [µm]
Sz [µm]
Point 1
3.402
2.536
27.709
Point 2
4.655
3.438
36.533
Point 3
4.616
3.541
37.549
Average
4.367
3.299
33.438
Standard deviation
0.647
0.519
4.527

(2) Sample B (20X objective, 3 ×3 stitching of 640 µm2 points for an effective field of vision: 1800 µm2)

Measurement point 1

Measurement point 1

Measurement point 2

Measurement point 2

Measurement point 3

Measurement point 3

Parameter
Sq [µm]
Sa [µm]
Sz [µm]
Point 1
8.467
6.927
57.411
Point 2
9.235
7.576
57.320
Point 3
9.190
7.488
63.444
Average
8.983
7.340
59.441
Standard deviation
0.354
0.288
2.867

LEXT OLS5500

Hybrid 3D Optical Profilometer

  • Traceable surface measurements from the nanometer to micrometer scale
  • Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
  • First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
  • WLI mode delivers up to 40x faster measurement throughput than conventional LSM
  • Exceptional precision across surfaces with in-house engineered optics
  • Intuitive interface and smart automation streamline operation for users of all levels
  • AI-enhanced and high-throughput workflows with PRECiV™ software integration

*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.

Learn More

LEXT OLS5100

The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.