Application Notes
Evaluating the Oil Groove Configuration of the Big End of Connecting Rods
Connecting rod
Application
Connecting rods convert the up/down motion of pistons in engine cylinders into the rotational movement of crankshafts. The section of the connecting rod that slides against the crankshaft is referred to as the “big end,” the interior of which is lined with two thin shell components called con-rod bearings. These con-rod bearings are subjected to strong frictional force. For a connecting rod to slide smoothly against the crankshaft, the surface of the big end needs to be adequately lubricated. For this purpose, grooves are required on the inner surface of the big end to maintain a sufficient amount of lubricant. The oil grooves are configured according to precise technical specifications to ensure that the con rod slides as intended. Accordingly, the oil grooves need to be measured with high precision to ensure they meet the technical specifications. To enable microscopic observation of the interior surface of the big end, the connecting rod must be secured vertically in a custom fixture. However, when oriented this way on the observation stage of a microscope, the overall height of the con rod sample may obstruct the movement of the objective lens.
Evident' solution
The Evident LEXT OLS5000(Formerly Olympus LEXT OLS5000) 3D measuring laser microscope is used to measure the oil grooves.
The OLS5000 microscope, when fitted with an optional extension frame, is capable of measuring samples up to 210 mm in height, enabling the observation of connecting rods mounted in a fixture.
Product characteristics
- The microscope’s extension frame enables observation/measurement of samples up to 210 mm in height.
- Measurement performance is enhanced to 4 times the speed of the previous LEXT model.
- Superior resolution (plane resolution: 0.12 µm) achieves high-precision measurement.
- Smart scan functionality for the acquisition of high-precision data helps eliminate data inconsistencies between operators.
Images
Connecting rod
Segmented big-end portion
Vertically oriented connecting rod mounted on a fixture
Connecting rod mounted on the LEXT OLS5000 microscope stage
Oil groove laser microscopy imagery (20X objective lens, 1x zoom)
Measurement of the oil groove configuration
Related products
LEXT OLS5500
Hybrid 3D Optical Profilometer
- Traceable surface measurements from the nanometer to micrometer scale
- Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
- First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
- WLI mode delivers up to 40x faster measurement throughput than conventional LSM
- Exceptional precision across surfaces with in-house engineered optics
- Intuitive interface and smart automation streamline operation for users of all levels
- AI-enhanced and high-throughput workflows with PRECiV™ software integration
*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.
https://main--evident-website-eds--evidentscientific.aem.live/en/microscopes/laser-confocal/ols5100/
LEXT OLS5100
The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.