Inspection in the MEMS Manufacturing Process/3D shape measurement of a micron-sized area using a laser microscope
Application
Technical innovations in the MEMS (micro-electro-mechanical-systems) market are remarkable; the commercialization of various sensors, ink-jet printer nozzles, medical devices, and other micro-electrical systems is under way in different fields. The shapes, structures, and implementation of MEMS methods are becoming more diverse and complicated. As components become smaller, it is increasingly important to have technology capable of accurately measuring very small areas.
The Evident solution
Evident' LEXT 3D laser scanning confocal microscope enables timely surface profile observations of intricate MEMS structures, surface profile measurements, and provides resolution and accuracy that were previously unavailable. For example, for a sample that is still in a wafer state, the LEXT can capture real-time 3D imaging of the wafer’s cross-section during grinding and determine quality during the etching process; inspectors no longer need to rely on electron microscopes (Figure 1).
Cantilevered beams are rigid structures anchored only at one end and are important components of many MEMS. If the delicate cantilevered beams become bent, electronic devices may not work properly. The LEXT is equipped for confocal imaging, an observation method for imaging only the area in focus, that can be used to instantly determine if a MEMS-specific cantilever structure is bent. When no bending is present, the microscope obtains an image of the sample entirely in focus (Figure 2, left). However, when bending is present, the deflected area of the sample is not in focus and will appear dark (Figure 2, right). This feature enables inspectors to quickly perform quality assurance on MEMS products.
MEMS 3D shape evaluation
Optical MEMS Objective lens Zoom
Micro lens array Objective lens Zoom
Figure 1
Cantilever deflection test using confocal observation
Cantilever With deflection
Objective lens: 50X Zoom: 1X
Cantilever With deflection
Objective lens: 50X Zoom: 1X
Figure 2
Related products
LEXT OLS5500
Hybrid 3D Optical Profilometer
- Traceable surface measurements from the nanometer to micrometer scale
- Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
- First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
- WLI mode delivers up to 40x faster measurement throughput than conventional LSM
- Exceptional precision across surfaces with in-house engineered optics
- Intuitive interface and smart automation streamline operation for users of all levels
- AI-enhanced and high-throughput workflows with PRECiV™ software integration
*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.
https://main--evident-website-eds--evidentscientific.aem.live/en/microscopes/laser-confocal/ols5100/
LEXT OLS5100
The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.