Application Notes
Measuring the Profile of a Bonding Wire Ball
Application: Measuring the Profile of Balls on IC Bonding Wire
Integrated circuits (IC) must have the proper electrical conductivity to work correctly. To achieve the proper conductivity, the integrated circuit chip and substrate must be securely bonded together. During the bonding process, the end of a wire made of a conductive metal, such as gold, is heated so that a ball forms at the end of the wire. The ball is then placed where the chip and substrate meet. Heat causes the ball to melt, fusing the chip and the substrate.
To help ensure that the bonding process works correctly, the profile of the ball at the end of the bonding wire is measured. However, this procedure is challenging since the system used to perform the inspection must be able to measure small, complex shapes.
Evident’ Solution: Measurement Using the OLS5000 Microscope
Measurement of minute, complex shaped objects is facilitated by the Evident LEXT OLS5000 (Formerly Olympus LEXT OLS5000) 3D laser scanning microscope’s advanced features:
-
To accurately measure the ball profile, the microscope uses dedicated objective lenses that are designed to work with its 405 nm wavelength laser to minimize aberration. These features enable the microscope to make minute measurements of objects with complex shapes.
3D image
Step measurement using a profile
- Unlike a stylus, which is a contact-based device, the OLS5000 microscope uses a noncontact laser scanner for its measurements. This system yields accurate data without damaging the sample.
-
The microscope’s 4K scanning technology enables you to obtain data for samples that have a steep inclination, such as a ball, with no measurement noise. With white-light interferometers, another noncontact device; the congestion of interference patterns prevents accurate measurement of steeply inclined surfaces.
3D image using a white-light interferometer
With the white-light interferometer no data can be acquired for the complex-shaped vertex and edge portions.
3D image using the LEXT OLS5000 microscope
Data can be acquired for both complex-shaped vertex and edge portions
Related Products
LEXT OLS5500
Hybrid 3D Optical Profilometer
- Traceable surface measurements from the nanometer to micrometer scale
- Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
- First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
- WLI mode delivers up to 40x faster measurement throughput than conventional LSM
- Exceptional precision across surfaces with in-house engineered optics
- Intuitive interface and smart automation streamline operation for users of all levels
- AI-enhanced and high-throughput workflows with PRECiV™ software integration
*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.
LEXT OLS5100
The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.