Application Notes
Measuring the Thickness of Photoresist Film
Photoresist image
Measuring the Thickness of a Photoresist Film
During the semiconductor manufacturing process, design patterns are printed on a silicon wafer using a technique called photolithography. To ensure that this pattern is accurate, the thickness of the photoresist film must be carefully managed. However, measuring the thickness can be challenging because of light reflected from the silicon beneath the resist.
Evident’ Solution: Thickness Measurement Using the OLS5000 Microscope
Measuring the thickness of photoresist film using the Evident LEXT OLS5000 (Formerly Olympus LEXT OLS5000) 3D laser scanning microscope is quick and easy due to its unique features:
Using the microscope’s top layer detection filter, scattered light from the silicon can be eliminated, even for transparent photoresist film, enabling proper thickness measurements.
The skip scan function enables the microscope to scan only the area that is necessary for data acquisition, helping to significantly speed up the scan speed. For example, a resist with a thickness of 23 µm can be scanned in as little as 10 seconds.
Related products
LEXT OLS5500
Hybrid 3D Optical Profilometer
- Traceable surface measurements from the nanometer to micrometer scale
- Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
- First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
- WLI mode delivers up to 40x faster measurement throughput than conventional LSM
- Exceptional precision across surfaces with in-house engineered optics
- Intuitive interface and smart automation streamline operation for users of all levels
- AI-enhanced and high-throughput workflows with PRECiV™ software integration
*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.
LEXT OLS5100
The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.