Olympus DP23M Monochrome Microscope Camera Simplifies Standard Fluorescence Imaging and Expression Checks
Premium image quality in a cost-effective camera
WALTHAM, Mass., October 6, 2021—The newest Olympus DP series microscope camera—the DP23M monochrome camera—continues the series’ reputation for delivering high-quality images. With advanced features found on high-end microscope cameras, the DP23M monochrome camera provides premium fluorescence images at a reasonable cost.
Fast, Efficient Fluorescence Protein Expression Checks
The camera’s sensitive back side illuminated monochrome CMOS sensor, 6.4-megapixel resolution, fast frame rate and advanced features combine to deliver bright fluorescence images of even very dim samples for fluorescence protein expression checks and routine fluorescence imaging and documentation. For added flexibility, the camera supports microscopy techniques besides fluorescence, including phase contrast, inversion contrast and differential interference contrast.
Fluorescence images are captured with a high signal-to-noise ratio while Olympus Smart Image Averaging (OSIA) further reduces noise during live viewing to make even small, subtle details in the sample visible. With a broad spectral range from 400 nm to 1000 nm, you can image samples using popular infrared dyes.
Simplify Routine Fluorescence Imaging
The DP23M monochrome camera comes equipped with high-end features that make imaging fast and efficient. The Fast Live function keeps the onscreen image clear while you move the sample to make it easier to locate areas of interest, even during long-exposure imaging. To speed up the focusing process, the Focus Peaking function helps you quickly decide and adjust the critical focus. A new sharpness filter enables you to use the camera with low magnification 10x objectives to see detail over a wide field of view and check multiple cells at the same time.
Start Imaging Fast
The DP23M camera is passively cooled and uses a single cable connection, making it compact and simple to set up—just plug in the USB cable. With seamless integration into Olympus cellSens imaging software, acquiring images is simple and intuitive.
For more information about the DP23M monochrome camera, visit www.Olympus-LifeScience.com.
About EVIDENT
In 2022, Olympus Corporation spun off its Scientific Solutions Division, which included its life science and industrial solutions businesses, to establish a new company called Evident. Although our name is different, our expertise, manufacturing capabilities, and commitment to our customers, which defined us over the past 100 years, remain unchanged.
At Evident, innovation and exploration are at the heart of what we do. Committed to making people’s lives healthier, safer, and more fulfilling, we support our customers with solutions that solve their challenges and advance their work; whether it’s researching medical breakthroughs, inspecting infrastructure, or exposing hidden toxins in consumer products.
Evident’s industrial solutions range from microscopes and videoscopes to nondestructive testing equipment and X-ray analyzers for maintenance, manufacturing, and environmental applications. Backed by state-of-the-art technologies, Evident products are widely used for quality control, inspection, and measurement.
In life science, Evident empowers scientists and researchers through collaboration and cutting-edge solutions. We’re dedicated to meeting the challenges and supporting the evolving needs of our customers, continuing to advance a comprehensive range of microscopes for pathology, hematology, IVF, and other clinical applications as well as for research and education.
For more information, visit EvidentScientific.com.
Olympus, the Olympus logo and OLYMPUS Provi are trademarks of Olympus Corporation or its subsidiaries.