Free Repair of the IPLEX™ GAir Video Borescope (IV9000GA Model)

Thank you for your continued business.

It has come to our attention that we had shipped the IV9000GA model of the IPLEX GAir long-distance video borescope with a weaker-than-standard torque value for fixing the screws on the main shaft inside the main unit.

As part of our quality control efforts, we are offering a free repair to customers using the affected products.

We sincerely apologize for any inconvenience this issue may cause to our customers, business partners, and other concerned parties. We will make continued quality control efforts to prevent its recurrence, and we ask for your understanding and cooperation in our efforts to maintain the high standards of our products.

Target Products

Product name: IPLEX GAir long-distance video borescope

Model name: IV9000GA

IPLEX GAir

Overall view of the IPLEX GAir industrial video borescope (model IV9000GA).

Side view of the main unit in the IV9000GA model

Fault

The screws securing the main shaft inside the main unit of the video borescope were shipped with a weaker torque value than standard. If the screws fall out due to this issue, it may lead to disconnection of the internal cables, which may result in loss of normal use.

Scope of Products Covered

Products listed in the serial number table below are eligible for free repair.

IV9000GA

No. Serial No. Serial No. Serial No. Serial No. Serial No. Serial
1 Y000001 26 Y000027 51 Y100052 76 Y100078 101 Y200103 126 Y300179
2 Y000002 27 Y100028 52 Y100053 77 Y100079 102 Y200104 127 Y300180
3 Y000003 28 Y100029 53 Y100054 78 Y100080 103 Y200105 128 Y300181
4 Y000004 29 Y100030 54 Y100056 79 Y100081 104 Y200106 129 Y300182
5 Y000005 30 Y100031 55 Y100057 80 Y100082 105 Y200107 130 Y300183
6 Y000006 31 Y100032 56 Y100058 81 Y100083 106 Y200108 131 Y300184
7 Y000007 32 Y100033 57 Y100059 82 Y100084 107 Y200109 132 Y300185
8 Y000008 33 Y100034 58 Y100060 83 Y100085 108 Y200110 133 Y300186
9 Y000009 34 Y100035 59 Y100061 84 Y100086 109 Y200111 134 Y300187
10 Y000010 35 Y100036 60 Y100062 85 Y100087 110 Y200112 135 Y300188
11 Y000011 36 Y100037 61 Y100063 86 Y100088 111 Y200114 136 Y300189
12 Y000013 37 Y100038 62 Y100064 87 Y100089 112 Y200115 137 Y300190
13 Y000014 38 Y100039 63 Y100065 88 Y100090 113 Y200116 138 Y300192
14 Y000015 39 Y100040 64 Y100066 89 Y100091 114 Y200117 139 Y300194
15 Y000016 40 Y100041 65 Y100067 90 Y100092 115 Y200168 140 Y300195
16 Y000017 41 Y100042 66 Y100068 91 Y100093 116 Y300169 141 Y300196
17 Y000018 42 Y100043 67 Y100069 92 Y100094 117 Y300170
18 Y000019 43 Y100044 68 Y100070 93 Y100095 118 Y300171
19 Y000020 44 Y100045 69 Y100071 94 Y100096 119 Y300172
20 Y000021 45 Y100046 70 Y100072 95 Y100097 120 Y300173
21 Y000022 46 Y100047 71 Y100073 96 Y100098 121 Y300174
22 Y000023 47 Y100048 72 Y100074 97 Y100099 122 Y300175
23 Y000024 48 Y100049 73 Y100075 98 Y100100 123 Y300176
24 Y000025 49 Y100050 74 Y100076 99 Y200101 124 Y300177
25 Y000026 50 Y100051 75 Y100077 100 Y200102 125 Y300178

*Units that have been used and contaminated under radiation, such as at nuclear power plants, are not covered because they cannot be repaired at the repair center. If a problem occurs with any of these units, please contact us individually to discuss how to handle the issue.

Request to Customers

If your product was affected, please contact us using our online inquiry form to request a free repair. Select Service/Repair for the department and Videoscopes and Borescopes for the product type. Then select the location that applies to your country/region.

When contacting us, please provide us with the following information:

(1) Product serial number

(2) Approximate year and month of purchase (If you are unsure, please let us know)

Personal information provided by customers, such as name, address, and telephone number, will be used only for the purpose of receiving, confirming inspection, delivery, and contacting customers for on-site inspection and repair of the applicable product.