Camera Adaptors
We provide a variety of camera adaptors to interface with imaging sensors, including 1X, 0.63X, 0.5X, and 0.35X C-mounts, bayonet, T-mounts, and F-mounts.
Nosepieces
Our revolving nosepieces can be used with either brightfield or brightfield/darkfield objectives and have a slider slot for DIC observation. Both manual and motorized nosepieces are available that accommodate from four to seven objectives. If you’re integrating software, coded nosepieces are available so that the software can read the magnification setting on the nosepiece. We also offer specially designed cleanroom-compatible motorized nosepieces for semiconductor applications.
Illuminators
Our universal illuminator is built to suit life science, industrial, and materials science equipment. It includes multiple positions for mirror cubes. Compact brightfield illuminators include filter slots for Nomarski and polarized light. And the control box is available that enable you to fully control the mirror cube position, aperture stop, and illumination intensity.
Light Sources
Our microscope frames are coupled with LED light sources but can also be fitted with a collimating adaptor to introduce a high-intensity halogen fiber or LED fiber options.
Observation Tube
If you need eyepieces to maximize the user's interaction with the microscope image, binocular and trinocular observation tubes are available. Options include erect tubes, tilting tubes, and tubes with a wide field of view (FN26.5).
Condensers
We offer condensers for transmitted light on both upright and inverted microscopes. The universal condenser enables you to perform many illumination techniques on one microscope. Phase contrast, darkfield, and long working distance condensers are available for various applications.
Autofocus Unit
The active laser autofocus improves the accuracy, repeatability, and speed of inspections. Our autofocus unit has a multi-spot array that substantially increases stability by eliminating the effects of vertical topography on the sample.
Magnification Changers
Magnification changers provide incremental magnification that can be beneficial when an imaging sensor requires a specific field of view. Magnification changer components are placed before the tube lens within the infinity space of the optical system.
The U-CA and U-ECA provide magnification increments of 1X, 1.25X, 1.6X, and 2X, and the U-ECA provides 2X magnification, and the U-ECA that can switch between 1X and 2X magnification. A coded magnification changer, the IX3-CAS (for inverted), is also available.
Digital Cameras
Cameras are available on request; please contact your local Olympus Components representative.
Camera Ports
Additional camera ports can be used within the system’s infinity space to add an input or output detector.