DP23 Digital Microscope Camera

6.4 Megapixel CCD Color Camera. 60 frames per second full HD live images. Fits standard c-Mount. USB 3.1 Gen1 (compatible with USB 3.0). Includes cellSens Entry imaging software. *Requires c-mount and 0.5-1.0X adapter (0.5X recommended)

DP23 Microscope Digital Cameras

Laboratory Microscope Camera

Designed for routine life science and clinical research microscopy imaging, the DP23 digital microscope camera’s combination of smart features and good color reproduction provide high-quality images in an easy-to-use camera.

Fast Microscope Camera

Quickly capture images with the level of detail required for most life science imaging applications.

  • 6.4-megapixel high resolution at 45 frames per second (fps)
  • Designed for local and remote image sharing for conference and consultation
  • 60 fps full HD live images
Fast HD Microscope Camera
Accurate Color Rendering

Reliable Color Rendering

The DP23 camera realizes good color reproduction on your monitor.

  • Dedicated ICC profiles show your samples in their natural colors
  • Common life science dyes look the way you expect them to
  • Use with Olympus’ True Color LED light source and the BX53 microscope for a complete color-optimized system

Large Field of View Microscope Camera

See more of your sample with an incredibly large field of view (FOV) up to FN25.

  • Images are sharp, flat, and in focus from the center to the periphery
  • Use with our latest optics—including X Line objectives and a 0.35X camera adaptor designed for a wide FOV— to maximize the camera’s potential

*Your microscope system must be compatible with an FN25 FOV.

Large Field of View Microscope Camera

Easily Share Microscope Camera Images

Make your collaborations more efficient. All your critical data—images, annotation, and live measurements—can be easily displayed and shared together locally or remotely.

  • Share images and data using cellSens software with the NetCam solution or remote image sharing feature* with network sharing in the standalone camera control module
  • Simple click-to-start image sharing
  • Support for NIST, GDPR, and antivirus software* for safer sharing

*Remote image sharing and antivirus software are optional.

The DP23 is not for clinical diagnostic use.

Applied Technologies

Smart Microscope Camera

  • Olympus Smart Image Averaging (OSIA) suppresses noise and eliminates artifacts while maintaining a fast frame rate
  • Focus peaking helps you identify which sample regions are currently in focus
  • High contrast mode enables easier image acquisition with a high signal-to-noise ratio so that you can capture high-quality images from dim samples during polarization and fluorescence microscopy
  • Fast live function provides a consistently high displayed frame rate during long-exposure imaging
Fluorescence image captured using high contrast mode

Inserting image...

Easy-to-Use Microscope Camera

  • Simple and intuitive software interface enables you to acquire images with just a single click for an efficient workflow
  • Attach the camera’s standalone module to the back of your monitor to free up valuable desk space
  • Plug the camera cord into your computer’s USB 3.1 port*, and it’s ready to use—no separate AC adaptor required

* USB 3.1 Gen is compatible with USB 3.0.

Specifications

Image Sensor
  • 1/1.8 inch Color CMOS
Resolution (max.)
3088 (W) x 2076 (H) pixels
Pixel Size
2.4 × 2.4 μm
A/D Converter
10 bits
Binning
  • 2 × 2
Exposure Times
29 µs– 15 s
Live Frame Rates
Max.45 fps at 3088 × 2076 (Full Resolution)
Max.58 fps at 2072 × 2072 (Square)
Max.60 fps at 1920 × 1080 (Full HD) *1
Cooling System
-
External Trigger
-
Data Transfer
USB 3.1 Gen1 *2
Partial Readout
✓
PC Control
Windows10 Pro(64bit)
Windows11 Pro(64bit)
PC Requirements

CPU: Intel® Xeon, Intel® Core i5, i7, i9
RAM: 8GB
Recommended:

  • 6 or more physical CPU cores
  • 16GB RAM (8GBx2 : dual channel)
Stand Alone
✓

*1 Frame rate may decrease depending on the condition of your PC and/or software. It is recommended that you use a dual-channel memory configuration for your PC.
*2 USB 3.1 Gen1 is compatible with USB 3.0.

Microsoft and Windows are registered trademarks of Microsoft Corporation in U.S. The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. in the United States and other countries. All brand names or production names described in this web site are trademarks or registered trademarks of relevant owners.