DP23M Digital Microscope Camera

High-Quality Fluorescence
Images within Reach
The cost-effective DP23M monochrome digital microscope camera makes it easy to capture high-quality fluorescence images. Simplify checking fluorescence protein expression and routine fluorescence imaging and documentation.

DP23M - Digital Microscope Camera

Overview

High-Quality Fluorescence Images within Reach

The cost-effective DP23M monochrome digital microscope camera makes it easy to capture high-quality fluorescence images. Simplify checking fluorescence protein expression and routine fluorescence imaging and documentation.

Easy Fluorescence Imaging

The camera’s sensitivity and resolution deliver bright fluorescence images, even for dim samples.

  • See subtle and small details: the backside illuminated monochrome CMOS sensor with 2 × 2 binning and Olympus Smart Image Averaging produce high signal-to-noise ratio images
  • Use with popular near-infrared dyes: the broad 400 nm to 1000 nm spectral range enables you to use NIR dyes with reduced endogenous sample background fluorescence
  • More than fluorescence: the camera’s 6.4-megapixel resolution and fast frame rate support high-resolution phase contrast, inversion contrast, and differential interference contrast imaging

Simplified Support—Camera, Software, and Hardware from Olympus

Combine the DP23M camera with a CKX53 microscope and cellSens software for an easy-to-use solution for routine cell culture monitoring and expression checks. Weak fluorescence signals from a range of dyes can be viewed clearly thanks to the camera's advanced technology and use of the same high-performance filter cubes found on Olympus microscopes. As a fully integrated solution from Olympus, support is just a call away.

*Although it became one of the most important cell lines in medical research, it’s imperative that we recognize Henrietta Lacks’ contribution to science happened without her consent. This injustice, while leading to key discoveries in immunology, infectious disease, and cancer, also raised important conversations about privacy, ethics, and consent in medicine.
To learn more about the life of Henrietta Lacks and her contribution to modern medicine, click here.

Applied Technologies

Time-Saving Technology for Fluorescence Imaging

  • Quickly find areas of interest: images remain clear while you’re moving the sample—even at long exposure times—thanks to the camera’s fast live function, so you don’t have to wait for the camera to refresh
  • Fast, responsive imaging: focus peaking can help you determine and adjust the critical focus quickly and reduce phototoxicity by exposing your sample only as long as needed
  • Observe multiple cells at once: when used with low magnification objectives, the camera’s high resolution and advanced sharpness filter enable you to see fine details over a wide field of view so that you can observe multiple cells at the same time

https://adobeassets.evidentscientific.com/content/dam/video/image/microscopesolutions/dp23m/movie_dp23m_setup_with_text.mp4

Easy-to-Use Monochrome Digital Camera

  • Compact: the camera uses passive cooling, making it small and lightweight
  • Easy to set up: connect the camera to your PC using a single USB cord and a standard C-mount adaptor
  • Intuitive image capture: with seamless cellSens software integration, you can acquire images quickly and easily; use the optional cellSens Count and Measure solution for assistance counting and measuring your cells to get data quickly and reliably

Specifications

Image Sensor
1/1.8 inch Backside illuminated monochrome CMOS
Resolution (max.)
3088 (W) x 2076 (H) pixels
Pixel Size
2.4 × 2.4 μm
A/D Converter
10 bits
Binning
2 × 2
Exposure Times
29 µs– 25 s
Live Frame Rates

Up to 45 fps at 3088 × 2076 pixels
Up to 58 fps at 2072 × 2072 pixels (Square)
Up to 60 fps at 1920 × 1080 pixels (Full HD 16:9)
Up to 58 fps at 1544 × 1038 pixels (Binning 2 × 2)

Frame rate may decrease depending on the condition of your PC, resolution of your monitor, and/or software.

Cooling System
Passively cooled
External Trigger
-
Data Transfer
USB 3.1 Gen1*
Partial Readout
✓
PC Control
Windows10 Pro(64bit)
Windows11 Pro(64bit)
Remark

Compatible PC Specifications - CPU: Intel® Xeon, Intel® Core i5, i7, i9 or the equivalent RAM: 8 GB

Imaging Platform - cellSens Entry, Standard, and Dimension, v. 3.2 or higher**; Service update for v. 3.2 required. PC Control Windows 10 64-bit

*USB 3.1 Gen1 is compatible with USB 3.0.

**cellSens software is not for clinical diagnostic use.