CX43/CX33 Upright Microscope

CX43 and CX33 biological microscopes enable you to remain comfortable during long periods of routine observation. The microscope frame conforms to your hands, and the location of the control knobs maximizes ergonomics to improve work efficiency. With minimal movement, you can quickly set a specimen with one hand, while adjusting the focus and operating the stage with the other hand. The microscopes can also feature an optional camera port for digital imaging.

CX43/CX33

Comfortable, High-Throughput Routine Microscopy

CX43 and CX33 biological microscopes enable you to remain comfortable during long periods of routine observation. The microscope frame conforms to your hands, and the location of the control knobs maximizes ergonomics to improve work efficiency. With minimal movement, you can quickly set a specimen with one hand, while adjusting the focus and operating the stage with the other hand. The microscopes can also feature an optional camera port for digital imaging.

Maintain Preferred Observation Conditions with Minimal Adjustments

  • CX43
  • CX33

Uniform Illumination with Consistent Color Temperature

The CX43/CX33 LED illumination provides several advantages, both immediate and over the long-term:

  • Produces daylight conditions so specimens can be viewed with their natural colors
  • Consistent color temperature at any brightness, so can avoid spending time making adjustments when you change the brightness
  • A long 60,000-hour lifetime with the brightness level remaining stable throughout

Fixed Köhler Illumination for Comfortable Viewing

CX43 and CX33 microscopes provide fixed Köhler illumination, enabling you to achieve the right illumination without adjusting the condenser.

CX LED Illumination

Fixed Koehler Illumination

Low-positioned focusing knob

Focusing stopper

Remain Comfortable during Extended Usage

  • CX43
  • CX33

Ergonomically Positioned Focus Knob

The low-positioned focusing knob enables you to conduct your observations while keeping your hands and forearms in comfortable positions resting on the desk. When working under high magnification, the focusing stopper prevents a specimen from accidentally hitting an objective.

Ergonomic Stage and Eyepiece Position

CX43 and CX33 microscopes offer features that support you through long hours in the lab:

  • Low-positioned stage to enhance comfort and reduce fatigue
  • Stage visibility from the eye point position to enable you to smoothly set and check specimens
  • Low stage knob that can be controlled with just a light touch, so you can quickly and comfortably view your specimens

Applied Technologies

Excellent Optical Performance for Flat Images

  • CX43
  • CX33

CX43 and CX33 microscopes can be used with plan achromat objectives, which provide clear images with high image flatness over a wide field of view. You can view specimens clearly with even illumination during routine observations.

*The CX43 is compatible with all UIS2 objectives while the CX33 comes with specially designed plan achromat objectives.

Excellent Optical Performance for Flat Images
https://adobeassets.evidentscientific.com/content/dam/image/product-gallery/cx43-33/product_CX43CX33.mp4

Flexibility for Multiple Applications

  • CX43

The CX43 microscope uses a standard universal condenser, offering a variety of observation methods:

  • Brightfield
  • Darkfield
  • Phase contrast
  • Fluorescence
  • Simple polarization

You can change the magnification from 2X to 100X without moving the top lens on the condenser.

Simple Fluorescence Observation

  • CX43

Fluorescence observation is simple and easy. Plug the compact fluorescent illuminator into the microscope frame and set the condenser turret to the FL position. The LED light source is pre-centered and has a long, 60,000-hour lifetime. Shutter the transmitted illumination by setting the condenser turret to the FL position to reduce the background noise cause by incidental light coming from the top of the condenser.

Smooth Magnification Change

Smooth Magnification Change

  • CX43
  • CX33

The revolving nosepiece is positioned at a lower height, enabling you to easily change objectives with your elbows resting comfortably on the desk.
The nosepiece also faces inward providing a larger working space when changing specimens or adding immersion oil.

Supports Up to Five Objectives

  • CX43

For added flexibility, up to five UIS2 objectives can be supported on the revolving nosepiece. In addition to general objectives, you can select a 2X objective for wide area observation or objectives for phase contrast.

Use Up to Five Objectives

Left: CX41 with the aperture stop closed and condenser down / Right: CX43 with the aperture stop closed /Sample: waxy cylinder

Left: CX41 with the aperture closed and condenser down /Right: CX43 with the aperture stop closed/Sample: trichophyton

Contrast Enhancement with a Simple Aperture Stop Operation

  • CX43
  • CX33

Quickly enhance the contrast by narrowing down the aperture diaphragm. This technique provides the same, if not better, image when adjusting the condenser.

Keep Your Desired Contrast Level and Observation Setting

  • CX43

The CX43 microscope offers two different fixing pins that can help improve the observation workflow and reduce operation errors:

  • Maintain your desired contrast level using a fixing pin on the aperture diaphragm
  • Keep the microscope set to brightfield observation, if desired, using the fixing pin on the condenser
Keep Your Optimal Contrast Level

Specimen holder sheet/ Double specimen holder

Specimen Holders that Match Your Observation Style

  • CX43
  • CX33

Multiple stage accessories are available to help improve efficiency. When using the specimen holder sheet, there’s no need to pinch the specimen with the holder. Instead, the holder enables you to easily maneuver the slide while it’s on the sheet. The double specimen holder can hold a large specimen or two standard sized glass slides.

Easily Capture and View Images with a Digital Camera and Heads-Up Display

Easily share and display images with your colleagues using the wireless LAN-enabled EP50 digital camera. Combine this camera with our CX series microscopes to transform your lab into a digital one. The heads-up display enables easy viewing in a group setting. Everyone can see the observed specimen in real-time without having to take turns viewing through the oculars.

* Third-party products may not be available in some countries.

Easily Capture and View Images with a Digital Camera and Heads-Up Display

Observation Methods

The CX43 universal condenser offers a variety of observation methods and future upgradability. In combination with the five-position revolving nosepiece, multiple applications can be covered using the single microscope frame.

Brightfield

CX43 CX33

Kidney
Kidney

Brightfield

CX43 CX33

Cervical Cytology
Cervical cells

Brightfield

CX43 CX33

Tuberculosis
Tuberculosis bacteria

Darkfield

CX43 CX33

Erythrocytes and leukocytes
Erythrocytes and leukocytes

Phase Contrast*

CX43

HeLa cells
HeLa cells

Simple Polarization

CX43

Amyloid
Amyloid

Fluorescence

CX43

Tuberculosis bacteria
Tuberculosis bacteria

Fluorescence

CX43

Renal Glomerulus
Renal glomerulus

*Although it became one of the most important cell lines in medical research, it’s imperative that we recognize Henrietta Lacks’ contribution to science happened without her consent. This injustice, while leading to key discoveries in immunology, infectious disease, and cancer, also raised important conversations about privacy, ethics, and consent in medicine.
To learn more about the life of Henrietta Lacks and her contribution to modern medicine, click here.

Specifications

CX43

Observation Method Brightfield ✓
Darkfield ✓
Phase Contrast ✓
Fluorescence (Blue/Green Excitations) ✓(Blue Excitation only)
Simple Polarized Light ✓
Illuminator Transmitted Köhler Illuminator LED Lamp ✓
Fluorescence Illuminator LED Lamp ✓
Focus Focusing Mechanism Stage Focus ✓
Coarse Handle Stroke 15 mm
Features Coarse adjustment limit stopper
Torque adjustment for coarse adjustment knob
Revolving Nosepiece Manual Standard (5 positions) ✓
Stage Manual Manual Stages with Right-Hand Control

Built-in

X: 76 mm, Y: 52 mm

Condenser Manual Abbe Conenser NA 1.25 (2X–100X)
Observation Tubes Standard (FN18) Tilting Binocular ✓
Standard (FN20) Binocular ✓
Trinocular ✓
Tube Inclination Angle

Binocular, Trinocular 30°

Tilting Binocular 30°–60°

Trinocular Tube Light Path Selection (Camera : Observation) 50 % : 50 %
Interpupillary Distance Adjustment 48–75 mm
Dimensions (W × D × H) 211 mm × 376 mm × 393 mm (8.3 in. × 14.8 in. × 15.5 in.) (standard configuration)
Weight Approx. 7.3 kg (16.1 lb)

The CX43 microscope system comes standard with the stage and condenser included.

CX33

Observation Method Brightfield ✓
Darkfield ✓
Illuminator Transmitted Köhler Illuminator LED Lamp ✓
Focus Focusing Mechanism Stage Focus ✓
Coarse Handle Stroke 15 mm
Features Coarse adjustment limit stopper
Torque adjustment for coarse adjustment knob
Revolving Nosepiece Manual Standard (4 positions) ✓
Stage Manual Manual Stages with Right-Hand Control

Built-in

X: 76 mm, Y: 52 mm

Condenser Manual Abbe Conenser NA 1.25 (4X–100X)
Observation Tubes Standard (FN20) Trinocular ✓
Tube Inclination Angle 30°
Trinocular Tube Light Path Selection (Camera : Observation) 0%:100%, 100%:0%
Interpupillary Distance Adjustment 48–75 mm
Dimensions (W × D × H) 211 mm × 397 mm × 430 mm (8.3 in. × 15.6 in. × 17 in.)
Weight Approx. 7.0 kg (15.4 lb)
Objectives Plan Achromat
4X NA 0.1 W.D. 27.8 mm
10X NA 0.25 W.D. 8.0 mm
20X NA 0.4 W.D. 2.5 mm (optional)
40X NA 0.65 W.D. 0.6 mm
100XOil NA 1.25 W.D. 0.13 mm (optional)

The CX33 microscope system comes standard with objectives, eyepieces, trinocular, stage, and condenser included.