Overview

Setup, Inspection, and Analysis Software Solutions

Compatible with OmniScan SX flaw detector data, these software solutions assist you with setup configuration, automated data analysis, or post-inspection PC-based analysis and reporting.

Phased Array Ultrasonic Testing (PAUT) Beam Simulation Software

Visualize beam simulations and prepare effective inspection setups in advance using NDT SetupBuilder software. Make sure that your OmniScan SX flaw detector has all the tools you need when you head to the job site.

Perform OmniScan SX Data Analysis on a PC

Analyze UT, PA, and TOFD inspection data and generate reports using OmniPC 4 software. Using the PC-based software enables you to deploy the flaw detector in the field while performing analysis on previously acquired data acquired. OmniPC 4 software features the same practical analysis tools and intuitive menus of the onboard OmniScan SX software.

NDT SetupBuilder

NDT SetupBuilder design software is an integral part of the Olympus line of automated and semi-automated ultrasonic testing products. Nondestructive testing (NDT) personnel are able to reduce the time defining the appropriate inspection configuration for OmniScan flaw detectors. This step makes sure that the configuration is compliant with the inspection code, eliminating possible configuration errors.

General Interface

The NDT SetupBuilder software interface is based on two grids: Probe Sets and Groups. The grids are designed to offer quick visualization of probes, wedges, positions, and beam parameters.

Additional interfaces are available for wedge and probe definition and parameter validation.

The wedge menu gives access to wedges available in the Olympus database, plus the details of the model characteristics including length, width, and height. Top, side and end views enable the user to visualize the selected wedge.

Similarly, the probe interface provides access to the available probes and their corresponding parameters in the Olympus database.
NDT supervisors can use PC-based NDT SetupBuilder software to define the inspection technique and set ultrasonic beam parameters for their inspections. Supervisors can define the inspection technique either remotely or on-site, without the need to access an OmniScan. More importantly, following the definition of the inspection technique, the configuration can be imported to the OmniScan MX2 and SX thereby reducing configuration time and manipulation errors prior to the inspection.

Compound Scan

A single-group compound scan offers similar coverage as two sectorial scans

Olympus’ updated NDT SetupBuilder software now offers the capability to perform compound scan beams. This innovative inspection strategy consists of a mix between sectorial and linear beams and offers many advantages such as:

  • Higher probability of detection
  • Inspection of thicker material
  • Higher inspection speed
  • Shorter setup and calibration time
  • Faster data analysis

Tooltips

Explanations, or tooltips, can be displayed by pointing the mouse over the interface elements, including tabs, toolbars, and dialog boxes. Tooltips include a clear image and a description of the associated function. The software is simple to use, even for inexperienced users.

  • Export setup configuration to the OmniScan MX2 and SX
  • Export .law files
  • Configurable acquisition unit
  • Support plate, pipe and bar geometry
  • Support PA linear, TOFD, UT and dual matrix
  • Support sectorial, linear, single beam, and compound type
  • Custom weld template
  • Custom probe and wedge creation
  • Scan plan report
  • RayTracing
  • Top, side, end, and 3-D views
  • Beam formation and near field information
  • Element deactivation
  • Support true depth and half path focalization type
  • Metric and US customary units

2-D and 3-D Visualization

The RayTracing view displays a graphically rendered illustration of the part, probes, wedges, and groups in 2-D or 3-D. Display options include side, top, and end view in 2-D. Interactive parameter configuration controls and probe element information are also available.

More Than Just a Ray Tracing Tool

Export/Import Your Configuration and Group Description

All configurations supported by the OmniScan and created in NDT SetupBuilder can be exported as an .ondt setup file. NDT SetupBuilder software can also be used as a focal law calculator. Groups not supported by the OmniScan can be exported as .law files.

Export your configurations on a USB key or an SD card and import them into your OmniScan. Once imported, there is no need to go through the inspection configuration menus. Just calibrate, and the unit is fully functional.

NDT SetupBuilder Features

OmniPC 4

Perform your acquisition on any OmniScan instrument.

Export as a .txt file and perform analysis on the software of your choice.

Interface

  • Same Interface as the OmniScan Software
  • Full screen mode
  • Available A-scan visual references (sizing curve, TCG, ref amplitude, grid)
  • Volumetric linked view
  • Predefined weld-overlay display
  • End View with merged signal
  • Multigroup combined display
  • Ability to zoom in/out

Ease of Use

  • Available online help
  • Intuitive contextual menus
  • Keyboard and mouse shortcuts to boost the productivity level
  • Predefined lists of readings based on common applications
  • 8 selectable readings simultaneously displayed

Analysis

  • Lateral-wave (LW) synchronization
  • TOFD calibrations
  • Gate adjustment and synchronization (by group/context)
  • Export C-Scans to .txt files
  • Ability to display and edit indication tables
  • Built-in report generator (customizable)
  • Ability to include an image of each indication in the report
  • Software attenuation gain

OmniPC is a PC-based data analysis and reporting software that benefits from the same user interface, analysis and reporting features as the OmniScan.

Analysis

With OmniPC, the OmniScan unit can now be used strictly for scanning while analysis is performed simultaneously on a personal computer. This software can also be used in conjunction with extra-large screens for increased visibility, and with keyboard shortcuts for faster operations.

OmniPC software benefits from the same user interface as the OmniScan software. No need to learn new software for the analysis of your OmniScan data files.

Export C-Scan

OmniPC adds a new feature for corrosion applications. You can export the complete C-Scan values to a *.txt file for further analysis. The values can be visualized in the Notepad, Excel, Matlab or any other software in which you wish to do your analysis.

OmniPC Features