Inspection Services
Industries

Olympus Solutions for Inspection Services
When you’re in the inspection service business, you need nondestructive testing equipment that’s portable and reliable so that you can get the job done as efficiently as possible.
Inspection service companies are tasked with checking a wide variety of components that are used in many industries and applications, including weld inspection and corrosion monitoring. When working in remote locations, such as an oil pipeline, you need equipment that’s rugged and won’t break down. From conventional ultrasound, phased array, and eddy current testing to remote visual inspection to positive material identification with X-ray fluorescence, we manufacture equipment that’s reliable and easy to use so you can complete your work promptly.
More Resources
Blog (61)
Breaking Down the Technical Cleanliness Workflow Part 3: Particle Size Classification and Particle Count Extrapolation and Normalization
Breaking Down the Technical Cleanliness Workflow Part 2: Image Acquisition and Particle Measurement
3 Important Considerations when Using X-ray Fluorescence for Positive Material Identification
Challenge Accepted: Vanta Handheld X-ray Fluorescence (XRF) Analyzers Combine Accuracy and Durability to Thrive in the Harshest Conditions
Application Notes (95)
Selecting the Best Propagation Mode for a Reflector Using the AIM Modeling Tool for TFM (Total Focusing Method) Inspection
Conducting Steel Plate Surface Texture Topography Analysis with a Laser Scanning Digital Microscope
Automated ultrasonic testing (AUT) of girth welds with corrosion resistant alloys (CRAs) using the Olympus PipeWIZARD
Automated Ultrasonic inspection of Girth Welds in Seamless Pipes with the Olympus PipeWIZARD
3D Shape Evaluation for Diamond Electrodeposition Tools Using the Olympus OLS5000 Laser Confocal Microscope
Dual Matrix Array for Ultrasonic Inspection of Dissimilar Girth Welds of Large Diameter CRA-Clad Pipeline
How Recent Handheld XRF Developments Impact Plant Based Alloy Positive Material Identification (PMI) Testing
Case Studies (1)
Case Study: Inspecting Boiler Tube Welds Using the COBRA Ultrasonic Phased Array Solution Instead of Radiography
Videos (78)
The HVAC and Heat Exchanger Tubing Kit using the NORTEC 600D - Remote Field Testing Demonstration
The HVAC and Heat Exchanger Tubing Kit using the NORTEC 600D - Near Field Testing Demonstration
The HVAC and Heat Exchanger Tubing Kit using the NORTEC 600D - Eddy Current Testing Demonstration
Solutions (15)
Webinars (19)
Advantages of Eddy Current Array over Magnetic Particle and Penetrant Testing for Inspecting the Surface of Carbon Steel Welds
Advantages of Ultrasonic Thickness Gages over Flaw Detectors for Corrosion Thickness Measurements
Time-of-Flight Diffraction - An Introduction to TOFD and its role within the Non-destructive Testing Field
Diverse Uses of Advanced Ultrasonic Inspection Technologies for Pipeline Manufacturing, Construction, and Maintenance
Brochures (15)
White Papers (7)