Application Notes
Fluorescence, phase-contrast, and bioluminescence imaging of live cells incubated in plastic bottom dishes using a 20X high numerical aperture (NA) phase contrast objective lens
Introduction
Imaging stem cells incubated in plastic bottom dishes
Glass bottom culture dishes used for the fluorescence observation of live cells are commonly marketed by many incubation chamber manufacturers; however, some types of cells cannot be successfully cultured on a glass surface and require the use of plastic bottom dishes.
Certain types of stem cells, such as iPS cells (induced pluripotent stem cells) and ES cells (embryonic stem cells), are better able to differentiate into target cells when cultured on a plastic substrate. In fact, some cell types cannot be differentiated into target cells at all when incubated in glass bottom dishes. The downside of using plastic bottom dishes, however, is that fluorescence imaging is often complicated by the autofluorescence produced by the plastic material, resulting in a high degree of background signal. When this happens, the signal-to-noise ratio is impaired and it becomes more difficult to image the fluorescent sample.
Stem cell researchers want to be able to carry out vivid fluorescence observation while using plastic bottom dishes. In response to this need, Evident developed a 20X high NA phase-contrast objective lens (UCPLFLN20XPH) in which the numerical aperture is greatly improved compared to a conventional 20X phase-contrast objective lens. The improved numerical aperture produces a better signal-to-noise ratio enabling better fluorescence imaging with plastic dishes. As a result, researchers can more effectively observe the stem cell differentiation process with fluorescence time-lapse imaging and more easily assess the confluency or transfection rate of cells cultured in plastic bottom dishes.
In this application note, we demonstrate how Evident’ 20X high NA phase contrast objective lens enables vivid fluorescence and phase-contrast observation of stem cells in a plastic bottom dish as well as an example of bioluminescence imaging observation using the same objective lens.
Application: Fluorescence and phase-contrast observation using Evident’ 20X high NA phase-contrast objective lenses
Mouse embryonic stem (ES) cells with GFP-labeled histone (GFP-H2B) in the nuclei were incubated in plastic bottom dishes. These cells were imaged with a conventional 20X phase-contrast objective lens (NA=0.4) and then compared to images taken with Evident’ 20X high NA (NA=0.7) phase contrast objective lens.
Mouse ES cells expressing GFP-H2B
Fluorescence observation
Phase-contrast observation
Left:Conventional 20X phase-contrast objective lens LUCPLFLN20XPH (NA=0.45)
Right:20X high NA phase-contrast objective lens UCPLFLN20XPH (NA=0.70)
When the above images are compared, bright fluorescence images were acquired with the 20X high NA phase-contrast objective lens (UCPLFLN20XPH) and the nucleoli are easily observed. This is due to the fact that the objectives have an improved numerical aperture while retaining a long working distance (W.D.: 0.8–1.8 mm).
These images demonstrate that fluorescence images comparable to those obtained using glass bottom dishes can be acquired when the UCPLFLN20XPH objective is used. With the aid of a correction collar, the spherical aberration generated due to differences in the thickness of the plastic dish bottom can be easily corrected.
Photographic conditions:
Specimen: Mouse ES cells
Fluorescence label: GFP-H2B
Incubation chamber: Plastic bottom dish
Objective lens: High NA phase-contrast objective lens UCPLFLN20XPH
CCD camera: Digital microscope camera DP80
Microscope: Inverted research microscope IX73
Application: Increasing the fluorescence sensitivity of the CCD DP80 digital microscope camera using monochrome CCD mode
As described above, Evident’ high NA 20X phase-contrast objective lens (UCPLFLN20XPH) enabled vivid fluorescence and phase-contrast observation of cells incubated in a plastic bottom dish. However, when a dish is repeatedly taken out from the incubator to check the fluorescence of the specimen during experiments, it is necessary to minimize the phototoxicity produced by the excitation light. In this case, using a highly sensitive CCD camera can reduce the intensity of the excitation light while by reducing the duration of time that the sample is exposed to potentially cytotoxic light.
Evident’ DP80 digital microscope camera offers the dual functionality of color reproducibility and high-sensitivity monochrome CCD imaging. By employing the DP80’s monochrome CCD mode in conjunction with the 20X high NA phase-contrast objective lens (UCPLFLN20XPH), Nanog-GFP expressed in mouse iPS cells was efficiently detected at a lower light intensity, as illustrated by the images below.
Nanog**-GFP expressed mouse iPS cells**
Phase-contrast observation
Fluorescence observation
Photographic conditions:
Specimen: Mouse iPS cells
Fluorescence label: Nanog-GFP
Incubation chamber: Plastic bottom dish
Objective lens: High NA phase-contrast objective lens UCPLFLN20XPH
CCD camera: DP80 digital microscope camera
Microscope: Inverted research microscope IX73
Application: High-performance bioluminescence imaging
Evident’ 20X high NA phase-contrast objective lens (UCPLFLN20XPH) achieves outstanding performance for demanding applications such as bioluminescence imaging with plastic bottom dishes. Bioluminescence imaging enables the user to quantitatively detect gene expression at the single-cell level. This imaging modality can easily be performed with the Evident LV200, a microscope specifically designed for bioluminescence imaging. When the UCPLFLN20XPH objective is used with the LV200, multiple cells can be observed in a single field. As shown in the image below, phase-contrast and Nanog-Luc bioluminescence (yellow) can be easily visualized in mouse ES cells with high sensitivity at the single-cell level.
Photographic conditions:
Specimen: Mouse ES cells
Bioluminescence: Nanog-Luc
Incubation chamber: Plastic bottom dish
Objective lens: High NA phase-contrast objective lens UCPLFLN20XPH
Microscope: Bioluminescence imaging system LV200
Conclusion
The examples discussed illustrate that the Evident 20X high NA phase-contrast objective (UCPLFLN20XPH) enables vivid fluorescence, phase-contrast, and bioluminescence imaging of cells cultured in plastic bottom dishes. The UCPLFLN20XPH objective lens is compatible with the IX3-ZDC2 Z-drift compensator and the IX3 series of motorized inverted research microscopes. When equipped with a motorized stage, a fully-motorized cell-based assay system for plastic bottom dishes can easily be configured.
Products related to this application
IXplore Standard
Compound Microscope System
Optimized for basic multicolor fluorescence imaging and routine experiments, the IXplore Standard system is easy to operate and ergonomically designed. Even with standard cell culture vessels, it captures high-quality, publication-worthy images while providing accurate and repeatable results at high magnifications. The IXplore Standard system’s simplified workflow and ease of use facilitate a wide range of standard imaging applications.
- High repeatability and accuracy for standard imaging tasks
- Benefit from the same optical capabilities found in high-end IXplore systems
- Easily upgrade to encoded functionality to boost the reproducibility of experiments
https://main--evident-website-eds--evidentscientific.aem.live/en/objectives/ucplfln/
Semi-Apochromat Objectives for Cell Culture
UCPLFLN/LUCPLFLN
Enabling tissue culture observation through bottles and dishes, these universal semi-apochromat objectives feature a long working distance and high contrast and resolution. Providing flat images and high transmission up to the NIR region, they are well suited for brightfield, DIC, and fluorescence observation.
- Provides long working distance, universal objectives with excellent contrast and resolution in brightfield, DIC and fluorescence observations
- Displays flat images from high transmission factors up to the near-infrared region of the spectrum
- Dedicated to tissue culture observations through bottles and dishes
https://main--evident-website-eds--evidentscientific.aem.live/en/microscopes/inverted/ix73/
The inverted microscope system for advanced live cell imaging
IX73
- Unique deck system
- Semi-motorized system
- System solutions