OpenStand顕微鏡フレーム

このコンポーネント顕微鏡を、Evident製光学アクセサリー、Prior Scientific製ステージアクセサリー、広々とした作業エリア、大型電動Z軸移動範囲と組み合わせて、生理学、電気生理学、神経科学全般のイメージング研究用にカスタマイズします。

Flexible and Modular Electrophysiology Solution

Customize this modular microscope to your physiology, electrophysiology, and general neuroscience imaging research with its wide range of Olympus optics and Prior Scientific stage accessories, spacious working area, and large motorized Z-travel range.

メールでのお問い合わせ

A Slim Frame Design That Adapts to Your Needs

The OpenStand post-style frame provides several advantages compared to traditional microscopes:

  • Compact design enables easy configuration with optics and accessories for optogenetics, physiology, electrophysiology, neuroscience, and general imaging applications
  • Motorized Z with 130 mm of overall travel, accommodating a wide specimen range, from tissue sections to whole animals
  • Works with any generic light input, including most light guide compatible illuminators, and now available with a compact IR-LED transmitted light and pod controller
  • Removable transmitted light and adjustable condenser mount for easy transition between in vitro and in vivo imaging

Sagittal section of a mouse brain

NG2 cell culture

Intestine thin section

Cat testes stained

Mouse kidney thin section

Vibration-Free Optics to Ease Fine Recordings

A top concern for researchers conducting electrophysiology experiments is vibration during equipment manipulation. Olympus offers vibration-free optical components that help ensure excellent stability throughout experiments. Combined with our long working distance objectives and precise, aberration-compensated IR-DIC optics (covering visible, 775 nm, and 900 nm wavelengths), the stability of the vibration-free optics enables you to clearly observe deep into brain slices.

機能

Noise Reducing Automatic Programmable Power Settings (APPS)

Smart components provide configurable drive, holding, and rest settings for the electrical current running to control motors. This includes the ability to automatically shut down power at the end of movement, an invaluable tool that helps reduce electrical noise.

Automatic Programmable Power Settings (APPS) Mode

Large Motorized Focus Travel

Customizable for Your Specific Research Needs

You can customize the system with various Prior Scientific stage and component options to meet your specific research needs.

Microscope Translation Stage

Microscope Translation Stage

Post Mounts

Post Mounts

Z-Deck Stage Platform

Z-Deck Stage Platform

V-Deck Stage Platform

V-Deck Stage Platform

Micromanipulators

Micromanipulators

Vibration-Free Design

Magnification Changes

  • The intermediate magnification changer combined with the high NA long working distance 20X objective enables you to switch between low and high magnifications without objective changes

Minimal-Noise Operation

  • Vibration-free shutter slides horizontally to prevent detents or vibration
  • Adjustable click release on the 6-postion mirror turret releases with a screwdriver
Vibration-Free Design

Olympus’ High-Quality Optics for Electrophysiology Imaging

  • 775 nm IR-DIC and 900 nm Nomarski DIC optimized optics available for live tissue observation
  • Long working distance dipping objectives provide the flexibility and special angles required for electrophysiology experiments
  • Swing nosepiece (WI-SRE3) is uniquely slim and compact with a front-to-back swing motion to enable objective changes without interfering with electrodes and micromanipulators; objective positioning includes a vibration-free counter spring mechanism

仕様

Specifications

  • 200 mm throat depth
  • 126 mm manual focus adjustment range
  • 40 mm motorized focus travel range
  • 20 nm motorized focus resolution
  • 70 mm condenser adjustment range
  • 35 mm condenser focus range
  • Fluorescence capability up to 6 channels
  • Vibration-free magnification changer
  • IR-DIC optimized optics up to 900 nm
  • Simultaneous fluorescence/IR-DIC imaging
Specifications

Dimensions

Dimensions

カタログ・ビデオ・その他資料

動画

カタログ・マニュアル