MVX10 매크로 줌 현미경 시스템
높은 형광 효율성을 위해 설계된 MVX10 실체 현미경은 세포 수준 또는 전체 조직, 장기, 유기체 수준의 유전자 발현과 단백질 기능의 영향에 관심이 있는 연구자들에게 유연성을 제공합니다.
MVX10
개요
An Intuitive Macro Fluorescence Imaging System
Designed for high fluorescence efficiency, the MVX10 stereo microscope offers flexibility for researchers interested in the impact of gene expression and protein function at the cellular level or within whole tissues, organs, and organisms.
Innovative Single-Zoom Bright Macro Fluorescence
The MVX10 MacroView, employs a single-zoom optical path with a large diameter, which is optimized to collect light with revolutionary efficiency and resolution at all magnifications. From fluorescent observation of whole organisms, such as zebrafish, at low magnification to the detailed observation of gene expression at the cellular level at high magnification, the MVX10 features a unique pupil division mechanism in the light-path to mimic the effect of a stereo microscope.
Seamless Observation from 4x to 125x
With the parfocal objectives and two-position revolving nosepiece, switching between objectives is very quick and easy, requiring little refocusing. Therefore, with the 0.63x and 2x objectives, the uninterrupted magnification range is 4x to 125x (eye observation with 10x eyepieces). This in combination with the 2x magnification change slider, increases effective magnification to 250X.
Contribution to Work Efficiency
This makes fluorescence screening and verification of gene expression especially efficient, improves speed and precision, reduces judgment errors, and eliminates the need to switch back and forth between a stereomicroscope and inverted microscope.
The peerless NA and S/N ratios of the optical components mean that specimens can be exposed to the excitation light for shorter periods. This is also true at near-infrared wavelengths, where the MVX10 has excellent transmission properties throughout the entire spectrum, minimizing damage to the specimen.
Choice of Suitable Contrast and Observation Method
SZX2-ILLTQ/SZX2-ILLTS
With a slim design new LED transmitted light illumination bases have a lower height to enable a low eyepoint and easy access to base-mounted samples during observation and operation. New LED illumination base SZX2-ILLTQ four-position turret (SZX2-ILLTS one –position) enables the user to choose cartridges and to switch from brightfield (Standard/High/Low), oblique (Standard/High/Low), darkfield, polarized illumination and shutter with a simple turn. This makes the MVX10 a flexible microscope for various samples and observation tasks. Another advantage of LED illumination is a cooler base surface, which is suitable for long duration manipulation of live specimens. Power consumption is lower than a conventional 30W halogen light source. A life cycle of over 60,000 hours significantly reduces operation costs.
C. elegans
Oblique high-contrast cartridge(SZX2-COBH)
Medaka
Darkfield cartridge(SZX2-CDF)
SZX2-STL
The SZX2-STL stand a stable, broad working space for observing large specimens. Attaching the Motorized Focus
Unit (SZX2-FOA) creates a more comfortable work environment.
응용 기술
고급 형광 이미징 전용
모든 광학 구성품은 MVX10 현미경 시스템의 형광 성능에 기여합니다. 최신 기술과 재료를 통합하여 대물렌즈와 HQ 필터는 자가 형광을 감소시킵니다. 렌즈의 높은 수치의 개구수를 필터와 결합하면 신호-노이즈 비율이 향상되므로 희미한 형광 신호를 우수한 대비로 관찰할 수 있습니다. 모든 필터 큐브는 미광을 흡수하고 비구면 형광 수집기는 밝은 형광 이미징을 위해 빛을 추가합니다.
모든 응용 분야에서의 높은 광학 성능
고유 대물렌즈 제품군
MVX10 현미경은 입체 현미경과 동일한 작동 거리와 넓은 시야를 제공하는 것은 물론, 향상된 수치의 개구수(NA)로 해상도를 높입니다. MVX10 현미경용으로 특별히 설계된 0.63배, 1배 및 2배율 아포크로맷 대물렌즈는 고품질 이미지를 생성합니다. 세 가지 대물렌즈는 모두 동공 보정되어 뛰어난 이미지 평탄도를 제공하며, NIR에 대한 높은 투과율과 탁월한 색수차 보정을 나타냅니다. 이는 시간이 지남에 따라 저배율에서 고배율까지 효율적이고 빠르며 정확한 형광 관찰, 선별 및 이미징을 위한 유연성을 제공합니다.
빠르게 움직이는 표본에 이상적
0.63배율 대물렌즈는 최대 시야각이 55mm이므로 시간이 지남에 따라 빠르게 움직이는 표본을 쉽게 추적할 수 있습니다. 개구수가 0.15로 매우 높기 때문에, 전체 배아와 같은 큰 물체에서 발산되는 형광을 모든 배율에서 뛰어난 밝기로 볼 수 있습니다.
매질 내 표본에 최적화
MVX10 현미경에 사용할 수 있는 2.0배율 대물렌즈의 0.5은 가장 높은 개구수를 지닙니다. 이 Plan 아포크로맷 대물렌즈는 매질 내 표본 작업에 적합합니다. 보정환을 사용하면 렌즈를 미세 조정하여 용기와 매질의 다른 굴절률로 인한 불일치를 보정할 수 있습니다. 이는 예쁜 꼬마선충 혈관과 매질 내의 제브라피쉬를 최대 해상도로 볼 수 있게 해줍니다.
약한 형광 신호 포착 및 녹화
MVX10 현미경의 형광 최적화 매크로 줌 광학 시스템에 고감도 카메라를 부착하면 희미한 형광 신호의 밝은 이미지를 얻을 수 있습니다. 형광 반사경 장치를 전환할 때 정렬 불량이 최소화되므로 다중 노출 촬영 또한 용이합니다.
cellSensis 이미징 소프트웨어에 대해 자세히 알아보기
사양
Quad position LED transmitted light illumination base SZX2-ILLTQ,
Large stand SZX2-STL