应用笔记

联系我们

Borescope inspection of helicopter main gear boxes

Main gearbox (in the red box in the picture above)
Main gearbox (in the red box in the picture above)

Application—Borescope inspection of helicopter main gear boxes

During routine helicopter maintenance, inspectors use borescopes to check for any breakage or cracks in the gear or gear carrier of the main . The main (MGB) is the mechanism that transmits power from the engine to the main rotor. The MGB consists of multiple components, including a gear carrier and planet gears that are driven by the power from the engine. If the tip of the borescope comes into contact with these components during the inspection, the gear oil lubricating their surfaces can become attached to the objective lens, obstructing the view and reducing visibility for inspectors.

Application—Borescope inspection of helicopter main gear boxes

Solution Using IPLEX Industrial Videoscope Accessories

To help resolve the issue of impaired visibility caused by gear oil on borescope lenses during MGB inspection, Olympus offers two accessories for IPLEX series videoscopes—one that helps prevent the problem, and one that facilitates oil removal:

Oil cleaning tip adaptor

Olympus’ forward-viewing adaptor for IPLEX series videoscopes has a special capillary-activated design that helps remove oil that attaches to the surface of the objective lens. This oil clearing tip adaptor enables inspectors to continue the inspection without having to stop, withdraw the scope, and clean the lens (only compatible with certain IPLEX models.)

Oil clearing adaptor for IPLEX videoscopes
Oil clearing adaptor for IPLEX videoscopes

Rigid sleeve

By using the rigid sleeve, another IPLEX videoscope accessory, you can help prevent accidental contact between the tip of the scope and the inspected object. can help reduce the risk for gear oil attachment. The rigid sleeve also facilitates inserting the scope deep into the back of the , effectively expanding the range of inspection.

Rigid sleeve
Rigid sleeve

Conclusion

Using Olympus IPLEX industrial videoscopes can help alleviate a common problem in inspecting main of helicopters: poor visibility caused by gear oil obstruction. Using the oil clearing tip adaptor and rigid sleeve improve the efficiency and ease of this borescope inspection application, helping to ensure the safe and efficient operation of helicopters.

相关产品


https://main--eds-evident-website--evident-scientific.hlx.live/zh/rvi-products/iplex-nx/

IPLEX NX

高端的工业视频内窥镜系统地组合了多种先进功能,使用更具便捷性与耐久性。从高画质检测到外来异物的抓取,多样化的性能带给用户前所未有的体验。


https://main--eds-evident-website--evident-scientific.hlx.live/zh/rvi-products/iplex-g-lite/

IPLEX G Lite/G Lite-W

IPLEX G Lite工业视频内窥镜将强大的成像功能打包在一个小巧而坚固的机体内。轻便易携,可随身携带至任何地方,在具有挑战性的应用中,用户可以使用远程内窥检测工具,不仅图像清晰,而且操作简单,足以完成所需工作。

如果您需要在风机机舱狭小的区域进行检测,那么IPLEX G Lite风机版视频内窥镜可助您轻松完成工作,此设备机身小巧,便于携带,且具有强大的成像功能。