Which Analysis Method Is Correct for My Materials Sample?

Olympus microscope and analysis software

Philip Graham

14 November, 2017

The Basics of Phase Analysis, Porosity Analysis, and Particle Distribution

In industrial microscopy, there are many ways to quantify the materials in your sample. Today, we will look at three specific methods and discuss their similarities and differences. Phase analysis, porosity, and particle distribution all utilize light and color thresholding techniques to identify materials in your sample, but break out the data differently for your application.

Phase Analysis

Advanced phase analysis

Phase analysis is one of the most basic ways of identifying and sorting multiple materials in a sample. When you are looking at a sample through a microscope and seeing each material as a unique color or gray value (a phase), imaging software has separated those materials through the process of defining thresholds for each specific material. Each material (phase) is presented as a percentage of the total image or of a region of interest, so you will know quickly if proportions of materials in a sample are correct. Typical applications for this type of analysis include welding quality checks, die casting, steel microstructures, and composite materials.

Porosity Analysis

Porosity Analysis

Porosity analysis starts similarly to phase analysis but provides data specific to measuring pores. In this case, thresholding is used to identify the pores in a sample. Because pore size is often critical, filters are available to remove pores that are too small or too large. The porosity percentage, pore density, and maximum pore size are outputted. Thus, results can be based on the entire image or a region of interest. Typical applications for porosity analysis include voids in chemical materials and porosity in foam.

Particle Distribution

Particle Distribution

Particle distribution works similarly, but in this case, data can be distributed into different classifications based on size. Size is considered differently depending on the application, so options like area, Feret max, or equivalent circle diameter can be used to define size classifications. Classification distribution can also be considered differently depending on the application, so options for particle count, particle percentage, or area-weighted particle percentage can be selected. Typical applications for particle distribution include stability in suspension (e.g., sediments, paints), the efficiency of delivery (e.g., asthma inhalers), texture and feel (e.g., food ingredients), and appearance (e.g., powder coatings and inks).

Other Analysis Methods

Count & Measure Solution

If none of these methods meet your specific requirements, a comprehensive object detection and classification solution should fit your needs. Count and measure utilizes threshold detection to identify materials in a sample. Classification and distribution can be performed by more than 50 different options including shape, size, position, and pixel properties. Filters can be used in conjunction with each classification to refine the resulting data. All data can be output to workbooks and reports for clear presentation of your results.