Support Biopsy Efficiency with the Simplified Operation of the IX73 Inverted Microscope
The Challenge
With objectives of lowering the miscarriage rate and improving the implantation rate, preimplantation genetic testing (PGT) is rising in popularity worldwide; therefore, the number of embryo biopsies performed is increasing accordingly.
In an embryo biopsy, some cells are removed from the embryo under an inverted microscope using relief contrast observation. The appropriate contrast adjustment is required to determine the location to irradiate the laser and the suction the cells, but complex microscope operations can cause user fatigue.
Evident’ Solution to Improve the Efficiency of the Biopsy Workflow
Evident’ relief contrast enables observation of 3-dimensional oocytes in plastic dishes. Since the relief contrast imaging is unaffected by the polarizing effect of the plastic dish, you can clearly view the oocyte zona pellucida to check its condition.
In addition, the dedicated remote hand switch of the IX73 semi-motorized system makes it easy to achieve suitable contrast and magnification/condenser settings with the push of a button. Streamlining the microscope operation to a minimum enables users to concentrate on the delicate biopsy manipulations, which require careful attention. Since the motorized operation using the hand switch reduces user intervention above the stage, it also decreases the risk of accidentally touching the sample or needle of the injector.
Remote hand switch
Samples and images data are courtesy of Cooper Surgical Inc.
Summary of the IX73 Semi-Motorized System’s Advantages for Embryo Biopsies
The IX73 system’s remote hand switch simplifies and streamlines microscope operations, supporting reliable and efficient embryo biopsies. The improved microscope operation workflow helps you manage the increased embryo biopsy workload.
Comment by Dr. Watanabe
When performing an embryo biopsy using the IX73 semi-motorized system, I am impressed by the smooth control of the magnification and laser system with the dedicated hand switch. In the past, when changing the magnification, we had to touch the condenser and objective lens, which required careful operation. I, like many users, have experienced shaking the microscope by accidentally touching it too forcefully. The IX73 semi-motorized system enables you to perform these operations by lightly pressing a switch without touching the microscope, so you can focus more on the embryo biopsy itself.
This application note was prepared with the help of the following researcher:
Dr. Hideaki Watanabe
Sugiyama Clinic Shinjuku
Center for Reproductive Medicine and Implantation Research
IIX3-ICSI/IMSI inverted microscope
Products related to this application
ICSI/IMSI Platform
IX3-ICSI/IMSI
The IX3-ICSI system is designed to facilitate the use of intracytoplasmic sperm injection (ICSI) as part of the in vitro fertilization (IFV) process. Evident’ relief contrast method enables 3D oocyte observation in plastic dishes to check the zona pellucida condition. The IX3 semimotorized system has an ICSI-dedicated hand switch to instantly change the observation method and magnification with the simple touch of a button. Use the polarization method to observe the spindle and its position to confirm oocyte maturity and avoid damage during injection and the differential interference contrast (DIC) method to perform intracytoplasmic morphologically selected sperm injection (IMSI).
- Optimized for a smoother ICSI workflow
- Easy oocyte condition checks through spindle visualization
- Streamlined ICSI steps through motorized operation