High-Resolution Imaging of Bone Cell Interactions Using the FLUOVIEW FV3000 Confocal Microscope and an X Line 40X Oil Immersion Objective
Bone constantly remodels using a balance of osteoclastic bone resorption and osteoblastic bone formation. However, certain health factors can cause an imbalance, leading to brittle bone in bone diseases such as osteoporosis. To understand the mechanism of bone remodeling, it is important to observe the interactions between osteoclasts and osteoblasts.
In this study, we prepared a mouse tibial cross-section (Figure 1) and closely observed osteoclasts and osteoblasts in the boundary zone between bone marrow and cortical bone. This application typically requires using a low-magnification objective to capture a wide field of view in order to identify a region of interest, followed by using a high-magnification oil immersion objective to observe the details in higher resolution. However, this approach can be difficult since you may lose the region of interest while switching objectives.
Here, we found the region of interest in a wide field of view and observed the fine structures in high-resolution using only a 40X oil immersion objective without switching objectives.
Figure 1: Tibial cross-section
High-Resolution Imaging of Bone Cell Interactions Using an X Line 40X Oil Immersion Objective (UPLXAPO40XO)
We observed the boundary zone between the bone marrow and cortical bone in a mouse tibial cross-section, as well as the contact site (* in Figure 2a) of osteoblasts (green) with vascular endothelial cells (yellow), and the interaction site (# in Figure 2a) of osteoblasts with osteoclasts (red). The wide field of view of the 40X oil objective enabled us to acquire an image that shows where the high-magnification image is located on the overview image (Inset of Figure 2a).
Using scan zoom, we could closely observe the interaction site of osteoblasts with osteoclasts (Figure 2b). The image quality obtained using the X Line UPLXAPO40XO objective was almost the same as the one obtained using a UPLSAPO60XO conventional objective (Figure 2c).
Figure 2: Fluorescent images of a mouse tibial cross-section
Image obtained using 1x scan zoom with a UPLXAPO40XO objective
Image obtained using 3.45x scan zoom with a UPLXAPO40XO objective
Image obtained using 2.03x scan zoom with a UPLSAPO60XO objective
Imaging conditions
Microscope: FV3000 system
Objective: UPLXAPO40XO (UPLSAPO60XO used for reference)
Lasers: 488 nm (Alexa Fluor 488, green), 561 nm (Alexa Fluor 568, red), 640 nm (Alexa Fluor 647, yellow)
How the FV3000 Confocal Microscope Facilitated Our Experiment
High-Performance Imaging with X Line Objectives
X Line objectives’ high numerical aperture (NA) enables them to gather more light for brighter, higher resolution images.
Acquire High Signal-to-Noise Ratio (SNR) Images Under Low Excitation Light
Comment by Dr. Yukiko Kuroda
It was difficult to find the interaction sites during high-resolution imaging of osteoclast and osteoblast interactions when switching between a low-magnification dry objective for wide field of view and a UPLSAPO60XO objective for high-resolution imaging. Another challenge was adding oil during the imaging process. When we used the UPLSAPO60XO objective for the entire imaging process, it took a long time to find the region of interest due to the narrow field of view.
This study demonstrates that we could successfully find the interaction sites and acquire high-resolution images equivalent to ones captured with the UPLSAPO60XO objective using only a 40X oil immersion objective (UPLXAPO40XO) with a high numerical aperture (NA) equivalent to UPLSAPO60XO. As a result, we could efficiently observe the interactions between osteoclasts and osteoblasts using only the UPLXAPO40XO objective.
Acknowledgments
This application note was prepared with the help of Dr. Yukiko Kuroda. She is an instructor at Keio University and was responsible for the images in this study.
Products related to this application
FV5000
Confocal Laser Scanning Microscope
- Extraordinary clarity, speed, and reliability driven by groundbreaking innovations
- SilVIR™ detectors deliver photon-level quantitation, exceptional sensitivity, and ultra-high signal-to-noise
- Unmatched dynamic range captures the full signal spectrum and prevents saturation
- High-speed 2K resonant scanning and high-density 8K galvo scanning in one platform
- FLUOVIEW Smart™ software simplifies operation with intuitive controls and AI-powered automation
- TruResolution™ auto correction collar optimizes focus for over 20 objectives
- Modular design supports up to 10 laser lines and future multiphoton upgrades
- Laser Power Monitor (LPM) ensures stable illumination and reproducible results over time
FV5000MPE
Multiphoton Laser Scanning Microscope
- Compact fiber-pigtailed lasers enable deep, quantitative imaging in scattering tissue
- One-, two-, or three-line simultaneous MPE laser excitation for millimeters deep imaging
- SilVIR™, TruAI, and TruSight™ technologies deliver outstanding signal-to-noise and clarity
- MPE-optimized objectives, TruResolution™ auto correction collar, and automated IR laser alignment maintain sharp focus
- Available as an FV5000 system upgrade or a complete MPE system
- Fully tunable laser configurations available for more advanced multiphoton applications
FV4000
Confocal Laser Scanning Microscope
- Game-changing dynamic range for imaging from the macro scale to subcellular structures
- Multiplex up to six channels simultaneously with TruSpectral technology
- Redesigned high-speed, high-resolution scanners for fixed and live cell imaging
- Improved depth and photosensitivity with pioneering NIR capabilities and renowned optics
- Peace of mind with the reliable, repeatable SilVIR detector
- Industry leading* ten laser lines with a broader spectral range from 405 nm to 785 nm
*As of October 2023.
Extended Apochromat Objectives
UPLXAPO
These extended apochromat objectives offers a high numerical aperture (NA), wide homogenous image flatness, and 400 nm to 1000 nm chromatic aberration compensation. They enable high-resolution, bright image capture for a range of applications, including brightfield, fluorescence, and confocal super resolution microscopy.
- High NA, wide homogeneous image flatness, and wide range chromatic aberration compensation from 400 nm to 1000 nm
- Highly reliable precision image for wide applications from bright field/fluorescence microscopy to confocal /super resolution microscopy