FLUOVIEW FV4000 Confocal Laser Scanning Microscope

Transform your images with the new FLUOVIEW™ FV4000 confocal laser scanning microscope. Advanced imaging technology enables higher precision images to empower researchers with more reliable data from their samples. With our breakthrough SilVIR™ detector at the core of the system, achieve much lower noise, higher sensitivity, and improved photon resolving capabilities. With the FV4000 confocal microscope, researchers can acquire higher-quality, quantitative image data in less time and with less effort.

  • Product Status: This product and earlier FV series systems have been replaced by the FV5000.

FV4000 Confocal Laser Scanning Microscope

Transforming Precision Imaging

Our more than 100 years of optical expertise have led to the FV4000 microscope—a technological breakthrough that delivers profound image quality with the potential to change what you’re able to see and empower your research.

  • Superior image quality with our ultra-low-noise SilVIR™ detector and an industry-leading six channels, ten laser lines, and 400–900 nm dynamic range.*
  • Acquire confocal images up to 60x faster and super resolution images up to 8x faster than the FV3000.
  • Count the number of photons in each pixel and represent features as discrete histograms of photons captured at different wavelengths.
  • Game-changing dynamic range enables you to count from a few photons to thousands with linearity—a first in confocal microscopy.
  • Easy to use with minimal adjustments required to obtain high-impact images and data.

    *As of October 2023.

See brochures

“The detectors are easy to set up due to their high dynamic range. They can handle low signals but do also not switch off and perform well with high signals. This makes it very user friendly to set up the microscope. The photon counting mode is a highly appreciated function. The high precision and simple adjustment and high flexibility make the FV4000 a very valuable tool for imaging facilities with users of different experience levels and varying complexity in their imaging experiments.”

—Johannes Riemann, Center for Microscopy and Image Analysis, University of Zurich

https://adobeassets.evidentscientific.com/content/dam/mis/fv4000/media/videos/FV4000_Product_Ovewview_Video_Final.mp4

Breakthrough SilVIR™ Detector Technology: The New Gold Standard

Our advanced, silicon-based SilVIR™ detector makes it easier than ever to acquire precise, reproducible data.

The detector combines two advanced technologies—a silicon photomultiplier (SiPM) and our patented* fast signal processing design.

  • High dynamic detection enables the system to acquire weak and strong fluorescence signals in one image with good linearity and quantify the number of photons for better image analysis.
  • Widest available spectral detection wavelength (400–900 nm) enables you to use visible to near-infrared fluorescence dyes and capture data with high spectral efficiency**.
  • Ultra-low noise translates to ultra-dark backgrounds, so even very weak fluorescence stands out.
  • Unlike old detector technologies, the SilVIR detector's sensitivity remains constant over time for consistent, reproducible experiment data.

*Patent number US11237047

*As of October 2023

Learn more about the SilVIR detector

40x Brain Stitch

Neurofilament-heavy chain (NFH) in green, myelin basic protein (MBP) in red, glutathione S-transferase pi 1 (GSTpi) in blue. Mouse cerebellum captured with a UPLXAPO40X objective.
Sample courtesy of Katherine Given, Ph.D. Principal Investigator, Neurobiology University of Colorado Anschutz Medical Campus, Aurora, Colorado

Conventional detector
SiLVIR detector

The histogram on the image captured using the SilVIR detector shows a discrete pattern where the intensity can be converted to the photon number. The detector’s fluorescence intensity can be quantified as the photon number, and the background level is extremely low.

“I am really impressed with the system and its performance. The super sensitivity was really impressive.”

—Sara R. Roig, Advanced Microscopy Specialist, University of Basel

More Information from Your Confocal Images

The system’s updated TruSpectral technology combined with high sensitivity SilVIR detectors enable you to see more by making it possible to multiplex up to six channels simultaneously.

Stictch A01 GOO1 Projection Z

The neurovascular unit of a mouse hippocampus. Blue; DAPI cell nuclei, Green; GFAP AF488. Astrocytes, yellow; DsRed pericytes, magenta; collagen IV AF647 basement membrane of blood vessels, gray; AQ-4. Astrocytes water channel.
Sample courtesy of: Hiroshi Hama and Atsushi Miyawaki, Cell Function Dynamics, RIKEN CBS.

CytoSkelton 4 color cell

Cytoskeleton sample: HeLa cells stained with DAPI (blue), Pericentrin (Centrosome, green), a-Tubulin (Microtubules, Alexa-568; red) and phalloidin (Actin, Alexa-647; magenta).
Sample Courtesy of: Sample preparation Alexia Ferrand; sample acquisition Sara R. Roig and Alexia Ferrand. Imaging Core Facility, Biozentrum, University of Basel.

Easily Adapts to Changing Research Needs

Our FV applications are unique solutions available for the FV4000 microscope that provide outstanding value and flexibility.

Overview image of a Drosophila wing
Edge image of a Drosophila wing

Overview and edge images of a Drosophila wing (42-hour pupation). Stained with phalloidin (AlexaFluor 405, F-actin, Cyan), anti-phosphotyrosine antibody (AlexaFluor 555, cell surface, red), and anti-HRP antibody (AlexaFluor 647, axon, blue). Sample courtesy of: Sun Zhengkuan, Shigeo Hayashi, Laboratory for Morphogenetic Signaling, RIKEN Center for Biosystems Dynamics Research, Japan.

Gentler High-Speed Time-Lapse Confocal Imaging

https://adobeassets.evidentscientific.com/content/dam/video/video/library/_7_1.mp4

HeLa cells labeled by MitoView 720. XYZT imaging by 1K resonant scanner for 30 min.

Time-lapse imaging is easier with smart features:

  • Capture every moment of live cell dynamics: resonant scanner can acquire high-resolution images over a wide area
  • Minimal phototoxicity: the scanner’s short pixel dwell time reduces the time the focused laser beam rests on a single spot
  • Better signal-to-noise ratio: the SilVIR detector’s high sensitivity produces higher quality images at higher speeds
  • Greater precision: rolling average processing maintains qualifications and time resolution

Reproducible Image Data Between Users and Systems

The SilVIR detector has less sensitivity loss over time compared to previous-generation detector technologies. With our laser power monitor (LPM) and TruFocus™ Z-drift compensator, achieve reproducible images under consistent conditions. Different users on different days can acquire the same precise images using the same settings. Even the images acquired by different FV4000 microscopes can be compared and discussed using the same photon number intensity scale.

To further enhance reproducibility, the Microscope Performance Monitor makes it easy to check the system’s laser power, detection sensitivity, and optical performance, helping ensure that your FV4000 microscope is functioning at a consistent and high level.

Driving the Future of High-End Imaging Research

We designed the FV4000 microscope to benefit everyone who uses it—from the core facility manager to individual users sitting at the scope and running imaging experiments.

Core Facility Managers

PI and Group Leaders

Individual Users

Microscope Support and Service You Can Count On

We designed the FV4000 system to be easy to maintain:

We stand behind our products with a commitment to fast service and technical support. We offer various support plans to keep your microscope running at peak performance at a predictable cost as well as remote support options, so you don’t need to wait for an engineer or specialist to visit if you’re having an issue.

“Compared to other confocals I have experience with, yours was very stress-free to use (no fear of destroying the sample or feeling overwhelmed with the software/general operation) and required minimal amount of adjustments from the user in order to produce a good quality data without feeling that my options are limited.”

—Sanni Erämies, Tampere University / Imaging Facility Tampere Core Facility

Microscope Support and Service You Can Count On

Applied Technologies

See Further with NIR-Enabled Confocal Microscopy

Near-infrared (NIR) imaging is fully integrated into the FV4000, and all detectors work through the NIR range so that you can maximize the benefits of this imaging technique:

*As of March 2023.

Cell nuclei (DAPI; blue) cell membrane (AF488; green) nuclear pore (AF561; yellow)
microtubule (Qdot605; magenta) mitochondria (MitoTracker DeepRed; cyan) actin (AF750 phalloidin; gray)

HeLa cells labeled by 6 fluorochromes.

HeLa cells labeled by 6 fluorochromes.
Cell nuclei (DAPI; blue), cell membrane (AF488; green), nuclear pore (AF561; yellow),
microtubule (Qdot605; magenta), mitochondria (MitoTracker DeepRed; cyan), actin (AF750 phalloidin; gray).

Award-Winning Technology for Award-Winning Research

The FV4000 system's optical elements have a high transmission from 400 nm to 1300 nm, including the galvanometer and resonant scanner, which are coated in silver rather than aluminum.

Our award-winning X Line™ objectives are corrected for chromatic aberrations between 400–1000 nm. They also have a higher numerical aperture, excellent flatness, and very high transmittance from UV to NIR, increasing the multiplexing capabilities.

For improved colocalization reliability, our specialized A Line™ (PLAPON60XOSC2) oil immersion objective (ne~1.40) significantly minimizes chromatic aberration for strict colocalization analysis.

X Series

Higher-Quality Images Up to 60 Times Faster than the FV3000

A unique combination of advanced technologies delivers high-quality images faster than conventional laser scanning microscope systems.

  • High-resolution images at high speed: 1K × 1K resonant scanner at FN20 with 0.033 µs per pixel and the SilVIR detector enable you to rapidly acquire images with minimal noise
  • Exceptional quality macro images: quickly acquire stitched macro images with outstanding quality to maximize your time and research potential

“Together with the AI restoring tools, it gives a perfect combination for fast and high-quality volumetric imaging.”

—Edwin Hernandez, Core Facility Manager, Cajal International Neuroscience Center (CINC)

A total of 77 four-channel XYZ positions (11 × 7) were acquired using a 1K resonant scanner within 16 minutes to create the stitched image, which used to require 2 hours using a galvanometer scanner. The coronal section of an H-line mouse brain, cyan; DAPI (cell nuclei), green; YFP (neuron), yellow; Cy3 astrocytes, magenta; AlexaFluor 750 (microtubule). Sample courtesy of: Takako Kogure and Atsushi Miyawaki, Cell Function Dynamics, RIKEN CBS.

8x Faster Super Resolution Imaging*

The FV4000 microscope enables you to capture macro to micro to super resolution images with no additional hardware.

Easy: observe subcellular structures using our A Line HR objectives and super resolution software (FV-OSR).

Detailed: the software automatically optimizes the confocal aperture to detect high-frequency components and enhance their contrast down to 120 nm resolution.

Fast: acquire super resolution images 8x faster than previous-generation systems thanks to the SilVIR detector's ultra low noise.

*Compared to the FV3000.

Confocal mode 1 AU (first) versus super resolution mode (second)

Unlock Deeper Insights with High-Resolution 3D Imaging

https://adobeassets.evidentscientific.com/content/dam/video/video/library/D02-DAPI_Ki67AF790_ex785_em792lp_A01_G003_0001(2).mp4

HeLa cell spheroid labeled by DAPI (cyan, cell nuclei) and AlexaFluor790 (magenta, Ki-67). Imaging of the spheroid’s whole volume was possible by NIR 785 nm, although only surface area cell nuclei observation was possible using a 405 nm laser.

Quickly and easily capture high-resolution 3D images of thick samples.

Maximize Depth, Time, and Image Quality

  • Penetrate deeper into tissue with NIR’s longer wavelength and the SilVIR detector’s wide dynamic range and sensitivity.
  • Image deeper with less scattering and absorption since light scattering compounds—like melanin and heme—absorb less light between 700–1500 nm.
  • Image deeper than what’s possible with visible lasers using the 685 nm, 730 nm, and 785 nm diode lasers on the FV4000.
  • High NA silicone objectives minimize spherical aberration.
  • Silicone oil does not dry out at room temperature, enabling more efficient time-lapse imaging experiments.
  • Acquire stunning 3D images of thick samples using TruSight™ deconvolution.

Precise Dynamics of Live Cells with Less Damage

Typically, using longer wavelengths for fluorescence excitation for shorter periods of time is better for overall sample health. Using less phototoxic light means you can image for longer periods, enabling you to obtain more consistent and reproducible data from live cell imaging experiments.

The FV4000 system not only provides gentle time-lapse imaging via the 685 nm, 730 nm, and 785 nm lasers, but it also features a dedicated TruFocus Red Z-drift compensator to maintain the focus position. This upgraded TruFocus Red unit supports a larger range of wavelengths and is compatible with a wide range of objectives, including our high-performing X Line™ and A Line™ series.

“The New FV4000 will allow for faster imaging + better preservation of the sample…and will allow better reproducibility.”

—Alexia Ferrand, Advanced Microscopy Specialist, University of Basel

https://adobeassets.evidentscientific.com/content/dam/video/video/library/TruFocus_Z-Drift_Compensator_480.mp4

https://adobeassets.evidentscientific.com/content/dam/video/video/library/_7_2.mp4

Time-lapse photo stimulation: the laser injury was performed on C2C12 cells. The green pseudocolor represents the application of an FM 1-43 bath. The image was acquired with a 2 μs galvo scanner and a UPLSAPO60XOHR objective. A 405 nm laser was used for photodamage and a 488 was used to image. Sample courtesy of: Daniel Bittel and Jyoti Jaiswal, Center for Genetic Medicine Research, Children’s National Research Institute.

https://adobeassets.evidentscientific.com/content/dam/video/video/library/_7_3.mp4

Time-lapse image of HeLa cells stained with Hoechst33342 (nuclear, blue), MitoTracker Green (mitochondria, green), LysoTracker Red (Lysosome, yellow), SiR-Tubulin (tubulin, magenta), POR-SA-Halo (ER, cyan). Hoechst33342: Ex 405 nm/Em, MitoTracker Green: LysoTrakcer Red: SiR-Tubulin: POR-SA-Halo: Sample courtesy of: Masayasu Taki, Ph.D., Institute of Transformative Bio-Molecules (WPI-ITbM), Nagoya University, Japan, Yuichi Asada and Ryusei Aruga, Graduate School of Science, Nagoya University, Japan.

https://adobeassets.evidentscientific.com/content/dam/video/video/library/_7_4.mp4

A 17-hour, time-lapse image of HeLa cells stained with MitoTracker Red (mitochondria, magenta), POR-SA-Halo (ER, cyan). MitoTracker Red: Ex 561nm/Em, POR-SA-Halo: Ex 730nm/Em, Sample Courtesy of: Masayasu Taki, Ph.D., Institute of Transformative Bio-Molecules (WPI-ITbM), Nagoya University, Japan, Yuichi Asada and Ryusei Aruga, Graduate School of Science, Nagoya University, Japan.

Clear Images at Depth

Use our silicone immersion objectives with the FV4000 microscope and achieve clear images of features and structures deep within your sample. Silicone oil has a refractive index close to that of live cells or tissue, greatly reducing the spherical aberration as compared to air, water, or other oils. With less aberration, you can achieve clearer images of your sample at depth. And silicone immersion oil does not dry out at 37 ℃ (98.6 °F), making it effective for long-term time-lapse imaging.

https://adobeassets.evidentscientific.com/content/dam/video/video/library/Silicone_Objectives_withVO(4).mp4

AI Solutions for Confocal Microscopy

Stunning, Data-Rich Images in Less Time and with Less Effort

Get better images in less time and with less effort. TruAI™ denoise technology takes the already low-noise images from the FV4000 and reduces noise to ultra-low limits for stunning, data-rich resonant images.

To speed up image analysis, you can pretrain an AI model so that the system can automatically segment your image data, greatly reducing the workload of this often time-consuming manual process. Then, TruAI technology further streamlines the analysis so that you can get your data quickly.

Where Innovation Meets Imaging Excellence

Improve your resonant scanner image quality by incorporating TruAI noise reduction. Although resonant scanner images are effective in capturing cellular dynamics at high speeds with low damage, this usually causes a compromise in the S/N ratio. TruAI noise reduction can improve these images without sacrificing time resolution using pre-trained neural networks based on the noise pattern of the SilVIR™ detectors. These pre-trained TruAI noise reduction algorithms can be used for on-the-fly processing as well as post processing.

Brain sample: coronal section (50 μm) of a mouse brain stained with DAPI (nuclei, cyan), GFAP (astrocytes, green/488), MAP2 (microtubule-associated protein 2, neurons, and dendritic processes, cyan/647) and MBP (myelin basic protein, red/568). Sample courtesy of: Sample preparation Alexia Ferrand; sample acquisition Sara R. Roig and Alexia Ferrand. Imaging Core Facility, Biozentrum, University of Basel.

Processed with TruAI noise reduction (second)

HeLa cell mitochondria labeled by MitoView 720 acquired using a 1K resonant scanner. The maximum photon number was 3 photons.

Processed with TruAI noise reduction (second)

Faster, Easier Image Analysis

Image analysis requires data extraction using segmentation techniques based on intensity value thresholds. However, this can be time-consuming and is affected by the sample conditions.

TruAI image segmentation using deep learning helps streamline image processing and minimize sample variables for more accurate image analysis. It enables you to segment superior performance with weak fluorescence fluorescence images or tissues that are usually difficult to extract using the simple thresholding method.

TruAI detects the glomeruli features (second)

Configurations

The FV4000 microscope is engineered to be modular, making it easy for you to configure the system based on your applications and budget. You can start with a standard FV4000 and easily upgrade to multiphoton imaging by adding the MPE module as your research changes.

One Platform for Your Research Needs

Multiphoton and single-photon combination imaging in one sample is also possible. The FV4000MPE microscope is capable of second and third harmonic generation imaging, so different researchers or users can make the most out of the system. If your research requires a custom setup, the microscope’s modularity and optional ports enable you to customize the system to add extra lasers, cameras, detectors, and more.

Upgrade to FV4000MPE

Choose the Configuration that Suits Your Application

Specifications

Scanner
Galvanometer scanner
(normal imaging)
64 × 64 to 4096 × 4096 pixels, 1 μs/pixel–1000 μs/pixel
Resonant scanner scanner
(high-speed imaging)
512 × 512 pixels, 1024 × 1024 pixels
Field number (FN)
20
Spectral confocal detector
Detector
SilVIR detector (cooled SiPM, broadband type/red-shifted type)
Maximum channels
Six channels
Spectral method
VPH, detectable wavelength range 400 nm–900 nm
Laser
VIS laser
405 nm, 445 nm, 488 nm, 514 nm, 561 nm, 594 nm, 640 nm
NIR laser
685 nm, 730 nm, 785 nm
Laser power monitor
Built in
Image
High dynamic range photon counting (1G cps, 16-bit)

Resources

Application Notes

How To

White Papers

Insights

Videos

Product Resources