IXplore IX85 Inverted Motorized Microscope Platform
The IXplore™ IX85 platform delivers an unmatched level of customizability, allowing you to design or build an intelligent, high-performance imaging system that meets your specific goals. And with an industry-leading field number (FN) of 26.5mm plus an array of advanced end-to-end imaging and workflow features, the IXplore™ IX85 means you can capture more than ever before while dramatically reducing your acquisition times.
IXPlore IX85 – End-to-End Imaging Features
Clearer Insights, More Discovery
The IXplore™ IX85 platform delivers an unmatched level of customizability, allowing you to design or build an intelligent, high-performance imaging system that meets your specific goals. And with an industry-leading field number (FN) of 26.5mm plus an array of advanced end-to-end imaging and workflow features, the IXplore™ IX85 means you can capture more than ever before while dramatically reducing your acquisition times.
Expand Your View, Enhance Your Vision
See and capture more—and reduce your acquisition times—with an unmatched field of view (FOV) in the industry and an array of advanced end-to-end imaging features that set a new standard in clarity and precision, including groundbreaking new objective technology
Unmatched 26.5mm FOV
View more of your sample at once with an industry-leading field number (FN) of 26.5mm on two integrated imaging ports. Cover larger areas in fewer images, get more data in each image, minimize the need for image stitching, and speed up your workflows.
Comparison of how many cells you can acquire in different FN.
Cultured NIH 3T3 cells. Blue: nuclei, Green: tubulin, Red: HSP60, Gray: fibrillarin. Sample provided by EnCor Biotechnology Inc.
Experience New Levels of Precision Clarity
With an innovative, strategic selection of advanced beginning-to-end imaging features, the IXplore™ IX85 is setting a new standard in precision and clarity—enabling you to see more fine details than ever before and easily obtain impactful, publication-ready images.
One Platform, Infinite Possibilities
Stay at the forefront of technology with the IXplore IX85 Pro’s unmatched customizability. Now you can support diverse imaging modalities across a variety of applications with no sacrifice in performance—and empower your lab to stay prepared for whatever the future brings.
New Built-In Ports
Two built-in camera ports (left and right) and an optional third port enable enhanced functionality and the capacity to create a multi-camera configuration setup. Four optical paths are available: left (100%), right (100%), binocular (100%), and BI 50%/L 50%.
Versatile Deck Structure
Customize your microscope setup for your own experiments. An open frame design makes it simple to add or swap modules to customize functions as needed. You can also upgrade from one to two decks as research needs change.
New Built-In Threaded Holes
Built into the frame, threaded holes around the camera ports turn the IXplore IX85 Pro into a canvas for innovation, whether you’re building a custom system or integrating the frame into your product.
Modular System Design
Leverage the latest technology with a modular system that lets you upgrade and expand your platform as research needs evolve by adding features such as TruFocus™, environmental control, and imaging modalities like Spinning Disk and photomanipulation. Third-party compatibility supports top-tier incubation systems, motorized stages, and more.
Automated Acquisition Features
The IXplore™ IX85’s automated acquisition features, customizable interfaces, and efficient task management software allow you to work more efficiently while staying confident in your results. Your productivity is further enhanced by advanced real-time image processing and analysis.Time-saving innovations include the pioneering new gel objective, a new auto correction collar, AI-based automated sample finding, TruAI™ Z-drift compensator, effortless contrast control, and simplified well-plate acquisition—all backed by customizable interfaces that let you design your system to the way you work best.
IXplore™ Workflow Advantages
See Deeper into Your Samples with Our New Multi-Immersion Objective
Our new multi-immersion objective (LUPLAPO25XS) with groundbreaking new immersion technology lets you see deeper into your samples and reveal structures that were previously out of reach.
With industry leading silicone gel pad technology, the LUPLAPO25XS gives you the quality of silicone immersion with the useability of a dry objective. There’s no need to wipe or replace oil as you navigate across the sample, and there’s no risk of your immersion medium drying out during timelapse imaging. The LUPLAPO25XS is ideal for a wide range of applications, with crystal-clear imaging and no compromise in usability.
Robust, Future-Proof Reliability
Ideal for busy lab settings, long-term imaging projects, and live cell imaging, the IXplore IX85 frame provides you with durability and performance backed by exceptional service and support. Maximum stability delivers confidence in precise, consistent results.
Confidence in Every Use
With over 100 years The IXplore IX85’s durable frame design is built to withstand a multitude of use, ensuring consistent performance and reducing downtime. The IXplore IX85 provides you and your team with maximum stability, minimizing small movements that could disrupt delicate long-duration imaging experiments.
Support that Empowers
With the same service and support that you’ve come to know and expect, you can be confident that your IXplore IX85 will perform as intended for years to come.
Upgrade Expand Your Imaging Technology as Needs Evolve
With the IXplore™ IX85, you can invest in a modular microscope system that lets you upgrade and expand your imaging platform as research needs evolve by adding features such as TruFocus™, environmental control, and imaging modalities like Spinning Disk and photomanipulation. Third-party integration is easy with support for incubation systems, motorized stages, and more.
Live
Spin
Specifications
| IX85P1ZF | IX85P2ZF | ||
| Microscope frame | Optical system | UIS2 optical system | |
| Revolving nosepiece |
Motorized 6-position revolving nosepiece (DIC slider attachable), One position for Automated Correction Collar Simple water proof structure |
||
| Focus |
Stroke: 10.5 mm Minimum increment: 0.01 um, Maximum nosepiece movement speed: 3mm/s |
||
| Intermediate Magnification Changer |
3 positions (Coded) 1X / 1.6X / 2X |
||
| Light path selection |
Motorized 4 positions Eyepiece 100%, left 100%, right 100%, eyepiece 50%/left 50% |
||
| Deck insert layer | 1 layer | 2 layers | |
| Maximum port field number | Left/Right side port: FN26.5, BI port: FN22 Deck right side port: FN18 |
Left/Right side port: FN18, BI port: FN22 Deck right side port: FN18 |
|
| Focus compensator |
TruFocus Z drift compensator |
Offset method (Focus search, one-shot focus, continuous focus), Class 1 laser product, laser wavelength: 830nm |
|
| Transmitted light illuminator |
Pillar tilt mechanism (30 ° inclination angle, with vibration reducing mechanism), Condenser holder (with with 88 mm stroke, refocusing mechanism), Field iris diaphragm adjustable, 4 filter holders Light source: High power LED light source |
||
| Observation tube | Widefiled (FN22) |
U-TBI90BK Wide field tilting binocular U-BI90 Wide field binocular U-TR30-2/U-TR30NIR Wide field trinocular |
|
| Stage | Motorized stage |
IX5-SSA: Stage stroke: X: 116mm x Y: 78mm, maximum stage movement speed: 40mm/s, Knob controller 3rd party motorized stage |
|
| Mechanical stage with right handle | Stage stroke: X: 116mm x Y: 78mm, | ||
| Plain stage | 232 mm (X) x 240 mm (Y) stage size, stage insert plate exchangeable (ø110 mm) | ||
| Condenser |
Motorized long working distance condenser |
W.D. 27 mm, NA 0.55, motorized turret with 7 position slots for optical devices (3 positions for ø30 mm and 4 positions for ø38 mm), motorized aperture and polarizer |
|
|
Long working distance universal condenser |
NA 0.55, W.D. 27 mm 5 positions for optical devices (3 positions for ø30 mm and 2 position for ø38 mm) | ||
| Ultra long working distance | NA 0.3, W.D. 73.3 mm, 4 positions for optical devices (for ø29 mm) | ||
| Fluorescence illuminator |
L-shape-fluorescence illuminator |
L-shaped design with exchangeable FS and AS modules, slider shutter and ND filter poket | |
| Fluorescence mirror turret |
Motorized fluorescence mirror turret |
Motorized turret with 8 positions, built-in shutter, simple waterproof structurer | |
| Fluorescence light source |
U-LGPS: LED and LDP light source, Class 1 laser product 3rd party LED light source |
||
| Control unit (IX5-MCZ) | Nosepiece position, light path selection, filter turret position, FL shutter ON/OFF, DIA LED power, DIA LED ON/OFF, 4 customizable button | ||
| Control box (IX5-CBH) | PC interface | USB (Type-C), RS-232C | |
| Operating environment |
• Indoor use • Ambient temperature: 5 ºto 40 ºC (41 º to 104 ºF) • Maximum relative humidity: 80% for temperatures up to 31 ºC (88 ºF), decreasing linearly through 70% at 34 ºC (93 ºF), 60% at 37 º C (99 ºF), to 50% relative humidity at 40 ºC (104 ºF) • Supply voltage fluctuations: Not to exceed ±10% of the normal voltage |
||
IXplore Microscopes
IXplore IX85 Pro
The foundation of our IXplore™ IX85 Pro system, the IXplore™ IX85 delivers an industry leading FOV and an array of advanced end-to-end imaging features, allowing you to see and capture more than ever before while dramatically reducing acquisition times. Experience exceptional speed, clarity, and reliability with the IXplore™ IX85 microscope system.
IXplore IX85 Live
Designed to reduce photobleaching and phototoxicity, the IXplore™ IX85 Live system is optimized for physiological experiments involving live cell and tissue observation. Offering precise environmental control and enhanced rigidity, it supports long-term cell viability and stability for time-lapse imaging applications, such as in cancer, stem cell, and brain research.
- Maintain focus accurately and reliably in time-lapse experiments with TruFocus™ Z-drift compensation system
- Discover the real morphology of your cells with Olympus silicone immersion optics
IXplore IX85 Spin
The IXplore™ IX85 Spin system features a spinning disk confocal unit that enables fast 3D image acquisition, a large field of view, and prolonged cell viability in time-lapse experiments. Researchers can use it to perform rapid 3D confocal imaging with high resolution and contrast at greater depths for imaging into thicker samples. The spinning disk also helps to cut down on photobleaching and phototoxicity of samples upon excitation.
- TruFocus™ Z-drift compensation system maintains focus for each frame
- Precise 3D imaging with improved light collection using X Line™ objectives