20 Examples of Effortless Nucleus and Cell Segmentation Using Pretrained Deep-Learning Models

Deep learning cell segmentation

Manoel Veiga

Manoel Veiga

3 May, 2022

TruAI™ deep-learning technology is a breakthrough image analysis approach because it enables researchers to tackle applications that were impossible or challenging, such as reliable label-free analysis or tracking of living cells at very low intensities over several days.

For these applications, the analysis is performed through semantic segmentation—the ability to identify if a pixel belongs to the background or foreground of a given class. After semantic segmentation, post-processing steps such as watershed are applied to perform the final object segmentation (typically nuclei or whole cells).

Recently, TruAI deep-learning technology was improved with the introduction of instance segmentation. This capability merges the semantic segmentation and the subsequent splitting of objects into one step. Instance segmentation improves workflows by enabling you to tackle difficult applications in one step, such as segmentation of cells in cell colonies that require post-processing splitting steps.

TruAI deep-learning technology enables users to train with their own data from the start, so the generated TruAI deep neural network (DNN) models have extremely good performance. Researchers can develop libraries of DNNs for different applications and even share them with collaborators.

Yet, this implies that the deep-learning workflow always consists of three steps:

  1. Labeling with your own data
  2. Training
  3. Inference

Despite our user-friendly software, the labeling step is the most time-consuming task—especially for challenging applications where many objects need to be labeled to achieve good performance.

Simplified Segmentation of Cells and Nuclei Using Pretrained Deep-Learning Models

To improve this workflow, TruAI deep-learning technology now includes some pretrained models for nuclei and cells, which are the most common objects to be segmented in bioimage analysis. As a result, users can save the time spent labeling and training (Figure 1).

Image segmentation deep learning

Figure 1. Using TruAI-deep learning technology with your own application data for training and inference helps ensure optimal performance. For a faster approach, pretrained TruAI models enable you to perform the analysis in just one click.

TruAI pretrained models for nuclei and cells are trained to perform instance segmentation in fluorescence images for various scenarios, including a range of:

It is important to note that the pretrained models are general models and can’t perform the segmentation perfectly in all possible situations. To help you better understand their capabilities, we’ve put together a list of cell segmentation scenarios.

20 Examples of Nucleus and Cell Segmentation Using Pretrained Deep-Learning Models

The image examples below (Figure 2, a–t) show the performance of the nuclei (red) and cell (green) TruAI pretrained models in a variety of segmentation scenarios. This includes different cell lines, marker stainings, magnifications, resolutions, contrast, signal-to-noise ratios, and background inhomogeneities. Note that both models can be applied to the same image (Figure 2, p-t). The models can even be applied to nonspecific nuclei (Figure 2, q–t) or cell stainings (Figure 2p, s).

1. U2OS cells, nuclear staining, widefield 20x, medium confluency with cells of different sizes and morphologies

Deep learning image segmentation of U2OS cells

Figure 2a

2. HeLa cells, nuclear staining, widefield 10x, inhomogeneous background

Deep learning image segmentation of HeLa cells

Figure 2b

3. Pluripotenet stem cells, nuclear marker, widefield 20x, very high confluency

Deep learning image segmentation of pluripotenet stem cells

Figure 2c

4. Kidney organoid cells, nuclear staining, confocal spinning disk 30x, high penetration depth

Deep learning image segmentation of kidney organoid cells

Figure 2d

5. HeLa cells, nuclear staining, confocal spinning disk 40x, high contrast and resolution

Deep learning image segmentation of HeLa cells

Figure 2e

6. A549 human carcinoma cells, nuclear marker, confocal spinning disk 40x, low signal-to-noise ratio

Deep learning image segmentation of A549 human carcinoma cells

Figure 2f

7. Human tissue tumor cells, nuclear staining, widefield 20x

Deep learning image segmentation of human tissue tumor cells

Figure 2g

8. Mouse kidney tissue cells, nuclear staining, widefield 20x, thick specimen

Deep learning image segmentation of mouse kidney tissue cells

Figure 2h

9. Rat-1 cells, cytosolic staining, widefield 10x, high cell confluency

Deep learning image segmentation of Rat-1 cells

Figure 2i

10. SK-HEP-1 cells, cell contact staining, widefield 20x

Deep learning image segmentation of SK-HEP-1 cells

Figure 2j

11. Plant cells, autofluorescence, widefield 20x, low signal-to-noise ratio

Deep learning image segmentation of plant cells

Figure 2k

12. HeLa cells, nuclear membrane staining, widefield 20x

Deep learning image segmentation of plant cells

Figure 2l

13. huFIB cells, tubulin staining, widefield 20x

Deep learning image segmentation of huFIB cells

Figure 2m

14. Rat-1 cells, actin staining, widefield 20x

Deep learning image segmentation of Rat-1 cells

Figure 2n

15. BPAE cells, actin staining, point scanning confocal 40x

Deep learning image segmentation of BPAE cells

Figure 2o

16. Rat-1 cells, nuclear staining weakly bleeding into cytoplasm, widefield 20x

Deep learning image segmentation of Rat-1 cells

Figure 2p

17. HeLa cells, tubulin staining, widefield 4x, low resolution and low signal-to-noise ratio

Deep learning image segmentation of HeLa cells

Figure 2q

18. Rat-1 cells, cytosolic staining, widefield 20x

Deep learning image segmentation of Rat-1 cells

Figure 2r

19. COS-7 cells, mitochondria staining, point scanning confocal 40x

Deep learning image segmentation of COS-7 cells

Figure 2s

20. BPAE cells, tubulin staining, point scanning confocal 40x

Deep learning cell segmentation of BPAE cells

Expanded Deep Learning Capabilities for Cell and Nuclei Segmentation

The introduction of instance segmentation and pretrained models expands the capabilities of the TruAI toolset. Users can now save time by starting with the pretrained models and performing cell and nuclei segmentation in one click. For cases where the results are not optimal, users can convert the TruAI predictions into new labels and then apply corrections. These corrected labels serve as the basis for a new training, saving time and effort.

Our customers are already seeing the benefits of the expanded deep learning capabilites. Robert Strauss, Senior Scientist at the Danish Cancer Society Research Center, commented, “The pretrained nuclei recognition is absolutely stunning and now makes it possible to easily analyze very heterogenous samples without compromising on any cell fractions. Especially in high cell density areas, TruAI-based separation is clearly superior to intensity or edge detection, both speed- and performance-wise.”