Oil & Gas
Industries

Olympus Solutions for Oil & Gas
In the oil & gas industry, safety is the highest priority, and unplanned downtime is costly. A robust nondestructive testing program is important to help maintain the safety of people and the environment and keep pipelines operating efficiently.
Inspectors use X-ray fluorescence analyzers to verify that pipelines are made from the proper alloy and ultrasonic and phased array flaw detectors to check pipelines and welds for flaws and corrosion. Worker safety is paramount when it comes to inspections in challenging environments, like offshore and at height, so options like harnesses and one-handed operation make all the difference.
More Resources
Blog (42)
3 Important Considerations when Using X-ray Fluorescence for Positive Material Identification
Application Notes (87)
Selecting the Best Propagation Mode for a Reflector Using the AIM Modeling Tool for TFM (Total Focusing Method) Inspection
Inspecting Pipe Elbows for Flow-Accelerated Corrosion and Erosion-Corrosion Using the FlexoFORM™ Scanner
Inspecting Pipe Elbows for Pitting Corrosion and Cladding Delamination Using the FlexoFORM™ Scanner
Using the Vanta™ XRF Analyzer to Quickly and Accurately Sort Low-Magnesium Aluminum Alloys
High-definition observation of the metal structure of materials for thermal power plant piping
Conducting Steel Plate Surface Texture Topography Analysis with a Laser Scanning Digital Microscope
Automated ultrasonic testing (AUT) of girth welds with corrosion resistant alloys (CRAs) using the Olympus PipeWIZARD
Automated Ultrasonic inspection of Girth Welds in Seamless Pipes with the Olympus PipeWIZARD
Dual Matrix Array for Ultrasonic Inspection of Dissimilar Girth Welds of Large Diameter CRA-Clad Pipeline
How Recent Handheld XRF Developments Impact Plant Based Alloy Positive Material Identification (PMI) Testing
Case Studies (1)
Case Study: Inspecting Boiler Tube Welds Using the COBRA Ultrasonic Phased Array Solution Instead of Radiography
Videos (84)
The HVAC and Heat Exchanger Tubing Kit using the NORTEC 600D - Remote Field Testing Demonstration
The HVAC and Heat Exchanger Tubing Kit using the NORTEC 600D - Near Field Testing Demonstration
The HVAC and Heat Exchanger Tubing Kit using the NORTEC 600D - Eddy Current Testing Demonstration
Solutions (16)
Webinars (24)
Advantages of Eddy Current Array over Magnetic Particle and Penetrant Testing for Inspecting the Surface of Carbon Steel Welds
Time-of-Flight Diffraction - An Introduction to TOFD and its role within the Non-destructive Testing Field
Diverse Uses of Advanced Ultrasonic Inspection Technologies for Pipeline Manufacturing, Construction, and Maintenance
Advanced Phased Array Probe Strategies for the Inspection of Austenitic and Dissimilar Metal Welds