Measuring the Profile of a Bonding Wire Ball

TOP image

Application: Measuring the Profile of Balls on IC Bonding Wire

Integrated circuits (IC) must have the proper electrical conductivity to work correctly. To achieve the proper conductivity, the integrated circuit chip and substrate must be securely bonded together. During the bonding process, the end of a wire made of a conductive metal, such as gold, is heated so that a ball forms at the end of the wire. The ball is then placed where the chip and substrate meet. Heat causes the ball to melt, fusing the chip and the substrate.

To help ensure that the bonding process works correctly, the profile of the ball at the end of the bonding wire is measured. However, this procedure is challenging since the system used to perform the inspection must be able to measure small, complex shapes.

Wire bonding

Evident’ Solution: Measurement Using the OLS5000 Microscope

Measurement of minute, complex shaped objects is facilitated by the Evident LEXT OLS5000 (formerly Olympus LEXT OLS5000) 3D laser scanning microscope’s advanced features:

  1. To accurately measure the ball profile, the microscope uses dedicated objective lenses that are designed to work with its 405 nm wavelength laser to minimize aberration. These features enable the microscope to make minute measurements of objects with complex shapes. 3D image 3D image Step measurement using a profile Step measurement using a profile
  2. Unlike a stylus, which is a contact-based device, the OLS5000 microscope uses a noncontact laser scanner for its measurements. This system yields accurate data without damaging the sample.
  3. The microscope’s 4K scanning technology enables you to obtain data for samples that have a steep inclination, such as a ball, with no measurement noise. With white-light interferometers, another noncontact device; the congestion of interference patterns prevents accurate measurement of steeply inclined surfaces. 3D image using a white-light interferometer 3D image using a white-light interferometer With the white-light interferometer no data can be acquired for the complex-shaped vertex and edge portions. With the white-light interferometer no data can be acquired for the complex-shaped vertex and edge portions. 3D image using the LEXT OLS5000 microscope 3D image using the LEXT OLS5000 microscope Data can be acquired for both complex-shaped vertex and edge portions Data can be acquired for both complex-shaped vertex and edge portions

LEXT OLS5500

Perfilómetro óptico 3D híbrido

  • Mediciones de superficie trazables de nanómetros a micrómetros
  • Microscopía de escaneo láser (LSM), interferometría de luz blanca (WLI) y microscopía de variación de enfoque (FVM) en una sola plataforma premiada
  • Primer perfilómetro óptico 3D que ofrece precisión y repetibilidad* garantizadas para mediciones LSM y WLI.
  • El modo WLI ofrece una capacidad de procesamiento de mediciones hasta 40 veces superior a la de la LSM convencional.
  • Precisión excepcional en todas las superficies gracias a óptica de ingeniería propia
  • Interfaz intuitiva y automatización inteligente que agilizan la operación para usuarios de todos los niveles
  • Flujos de trabajo de alta capacidad de procesamiento optimizados con IA mediante la integración con el software PRECiV™

* Basado en la investigación interna de Evident a octubre de 2025. La exactitud y repetibilidad garantizadas solo se aplican si el dispositivo se ha calibrado según las especificaciones del fabricante y se encuentra libre de defectos. La calibración la debe llevar a cabo un técnico de Evident o un especialista autorizado por Evident.

Más información

LEXT OLS5100

El microscopio de escaneo láser LEXT™ OLS5100 combina precisión y rendimiento óptico a un nivel excepcional junto con herramientas inteligentes que facilitan su uso. Las tareas de medición precisa y submicrométrica con respecto a la forma y la rugosidad superficial son rápidas y eficientes, lo que simplificará su flujo de trabajo y proporcionará datos de alta calidad en los que puede confiar.