Evaluating the Internal Roughness of Injector Nozzles

Injector nozzle


Injector nozzle

Application

Injector components are used to inject fuel into combustion chambers. A needle inside the injector is electromagnetically guided up/down to open/shut the fuel injection orifice. This is a very delicate and precisely manufactured component, as the injector is narrow and the needle inside it is mobile. The interior of the tip portion of the nozzle where the fuel injection orifice is situated must be free of defects to ensure smooth movement of the needle. Since these nozzles are cylindrical, the cut-away section is a semicircular groove. In some cases, the working distance of objective lenses on microscopes are too short to clearly focus on the bottom of the grooves.

Evident' solution

The Evident LEXT® OLS5000(Formerly Olympus LEXT® OLS5000) 3D measuring laser microscope offers powerful roughness measurement features. The OLS5000 microscope is equipped with dedicated long working distance objectives, providing reliable roughness measurement for samples with a maximum depth of 6.5 mm.

OLS5000 microscope features

  1. A line of dedicated long working distance objective lenses (20X, 50X, 100X) for the OLS5000 microscope enables data acquisition from previously unmeasurable samples.
  2. Measurement performance is enhanced to 4 times the speed of the previous LEXT model.
  3. Capable of planar roughness measurements that are unattainable using conventional probe-based roughness gages, expanding the analysis options.
  4. Smart scan functionality for the acquisition of high-precision data helps eliminate data inconsistencies between operators.

Images

Cut-away section of an injector (Image supplied by MarkLines Co., Ltd.)


Cut-away section of an injector(Image supplied by MarkLines Co., Ltd.)

Roughness measurement of the nozzle’s tip(100X objective lens, 1x zoom)
Roughness measurement of the nozzle’s tip(100X objective lens, 1x zoom)

Cut-away section of a nozzle

Cut-away section of a nozzle

Roughness measurement of the nozzle’s base portion(100X objective lens, 1x zoom)
Roughness measurement of the nozzle’s base portion(100X objective lens, 1x zoom)

Prodotti correlati

LEXT OLS5500

Profilometro ottico 3D ibrido

  • Misurazioni superficiali tracciabili da nanometro a micrometro
  • Microscopia a scansione laser (LSM), interferometria a luce bianca (WLI) e microscopia a variazione di messa a fuoco (FVM) in un'unica piattaforma pluripremiata
  • Primo profilometro ottico 3D a offrire accuratezza e ripetibilità garantite* sia per le misurazioni sia LSM sia WLI
  • La modalità WLI offre una velocità di misurazione fino a 40 volte superiore rispetto alla LSM convenzionale
  • Precisione eccezionale su tutte le superfici grazie a lenti progettate internamente
  • Interfaccia intuitiva e automazione intelligente ottimizzano le operazioni per utilizzatori di tutti i livelli
  • Flussi di lavoro ad alta produttività e potenziati dall'intelligenza artificiale grazie all'integrazione con il software PRECiV™

*Dati basati sulla ricerca interna condotta da Evident fino a ottobre 2025. La precisione e la ripetibilità garantite si applicano solo se il dispositivo è stato tarato in base alle specifiche del fabbricante ed è privo di difetti. La taratura deve essere eseguita da un tecnico Evident o da uno specialista autorizzato Evident.

Maggiori informazioni