Application Notes
Roughness Evaluation of the Side Surface of Piston Rings
Piston ring
Application
Piston rings are attached to pistons to ensure that an engine’s combustion chamber remains airtight. The sides of piston rings need to maintain a certain level of roughness as they slide against the cylinder sleeve (the liner inside the cylinder). This roughness is integral to ensuring the smooth movement of the pistons in the cylinder while minimizing the abrasion caused by friction. Verifying the surface roughness of piston rings is essential during quality management inspections. Because piston rings are thin and ring-shaped, microscopic inspection of the sides involves securing the sample vertically in a customized fixture. When the piston ring is placed on the observation stage of a microscope fixed in this position, it can obstruct the movement of the objective lens.
Piston ring secured in a fixture
Evident’ solution
The Evident LEXT OLS5000 (formerly Olympus LEXT OLS5000) 3D measuring laser microscope is used to measure surface roughness.
The OLS5000 microscope, when fitted with an optional extension frame, is capable of measuring samples up to 210 mm in height, enabling the observation of piston rings mounted in a fixture.
OLS5000 microscope features
- The microscope’s extension frame enables the observation/measurement of samples up to 210 mm in height.
- Measurement performance is enhanced to 4 times the speed of the previous LEXT model.
- Superior resolution (plane resolution: 0.12 µm) achieves high-precision measurement.
- Smart scan functionality for the acquisition of high-precision data helps eliminate data inconsistencies between operators.
Laser microscopy imagery of the side surface of a piston ring
(50X objective lens; 1x zoom)
Prodotti correlati
LEXT OLS5500
Profilometro ottico 3D ibrido
- Misurazioni superficiali tracciabili da nanometro a micrometro
- Microscopia a scansione laser (LSM), interferometria a luce bianca (WLI) e microscopia a variazione di messa a fuoco (FVM) in un'unica piattaforma pluripremiata
- Primo profilometro ottico 3D a offrire accuratezza e ripetibilità garantite* sia per le misurazioni sia LSM sia WLI
- La modalità WLI offre una velocità di misurazione fino a 40 volte superiore rispetto alla LSM convenzionale
- Precisione eccezionale su tutte le superfici grazie a lenti progettate internamente
- Interfaccia intuitiva e automazione intelligente ottimizzano le operazioni per utilizzatori di tutti i livelli
- Flussi di lavoro ad alta produttività e potenziati dall'intelligenza artificiale grazie all'integrazione con il software PRECiV™
*Dati basati sulla ricerca interna condotta da Evident fino a ottobre 2025. La precisione e la ripetibilità garantite si applicano solo se il dispositivo è stato tarato in base alle specifiche del fabbricante ed è privo di difetti. La taratura deve essere eseguita da un tecnico Evident o da uno specialista autorizzato Evident.