General Biology
일반 생물학 연구
형광 및 명시야를 모두 지원하는 카메라가 필요한 고객을 위해 당사는 DP80 및 DP74 냉각 컬러 카메라를 제공합니다.
Pixel size (μm)
3.45 x 3.45 µm
2.4 × 2.4 μm
1.25 × 1.25 μm
2.64 x 2.64 마이크로미터
2.4 × 2.4 μm
Number of pixels (MP)
8.9
6.4
18
5
Image Sensor
1 in. color CMOS
1/1.8 inch Color CMOS
1/2.3 in. color CMOS
1/2.5 in. color CMOS
1/1.8 inch Color CMOS
Frame rate (fps)
at max resolution
Max.32 fps at 4104 × 2174 (Full Resolution)
Max.33 fps at 3840 × 2160 (4K)
Max.33 fps at 2168 × 2168 (Square)
Max.64 fps at 1920 × 1080 (Full HD) *1
Max.33 fps at 3840 × 2160 (4K)
Max.33 fps at 2168 × 2168 (Square)
Max.64 fps at 1920 × 1080 (Full HD) *1
Max.45 fps at 3088 × 2076 (Full Resolution)
Max.58 fps at 2072 × 2072 (Square)
Max.60 fps at 1920 × 1080 (Full HD) *1
Max.58 fps at 2072 × 2072 (Square)
Max.60 fps at 1920 × 1080 (Full HD) *1
10.5 fps at 4,912 × 3,684 pixels (4:3)
23.6 fps at 2,456 × 1,842 pixels (4:3)
45 fps at 1,224 × 920 pixels (4:3)
14 fps at 4,912 × 2,762 pixels (16:9)
25 fps at 3,840 × 2,160 pixels (4K UHD 16:9)
31 fps at 1,920 × 1,080 pixels (Full HD 16:9)
59 fps at 1,224 × 688 pixels (16:9)
23.6 fps at 2,456 × 1,842 pixels (4:3)
45 fps at 1,224 × 920 pixels (4:3)
14 fps at 4,912 × 2,762 pixels (16:9)
25 fps at 3,840 × 2,160 pixels (4K UHD 16:9)
31 fps at 1,920 × 1,080 pixels (Full HD 16:9)
59 fps at 1,224 × 688 pixels (16:9)
Up to 19 fps at 2,160 × 1,620 pixels (@ full resolution)
Up to 25 fps at 1920 × 1080 pixels (@ full HD)
Up to 40 fps at 1,296 × 972 pixels (@ fast mode)
Up to 25 fps at 1920 × 1080 pixels (@ full HD)
Up to 40 fps at 1,296 × 972 pixels (@ fast mode)
최대 30fps(PC에서 Full HD 16:9, 1920 × 1080픽셀)
최대 60fps(HDMI 출력, 1920 × 1080픽셀)
최대 25fps(WLAN 출력, 1920 × 1080픽셀)
최대 60fps(HDMI 출력, 1920 × 1080픽셀)
최대 25fps(WLAN 출력, 1920 × 1080픽셀)
Connector
USB 3.1 Gen1 *2
USB 3.1 Gen1 *2
USB 3.0
USB 3.1 Gen1 Type-C
HDMI, WLAN (using the WLAN adaptor), Ethernet (using the USB-to-Ethernet adaptor)
컬러
- 칼라
- 칼라
- 칼라
- 칼라
- WLAN
관찰 방법
- 명시야
- 형광
- 명시야
- 형광
- 명시야
- 명시야
Remark
Focus Peaking manual focus assist
ESIA - Evident Smart Image Averaging (active noise reduction)
*USB 3.1 Gen1 is compatible with USB 3.0
ESIA - Evident Smart Image Averaging (active noise reduction)
*USB 3.1 Gen1 is compatible with USB 3.0
Focus Peaking manual focus assist
ESIA - Evident Smart Image Averaging (active noise reduction)
*USB 3.1 Gen1 is compatible with USB 3.0
ESIA - Evident Smart Image Averaging (active noise reduction)
*USB 3.1 Gen1 is compatible with USB 3.0
Focus Peaking 수동 포커스 지원
ESIA - Evident Smart Image Averaging (active noise reduction)
ESIA - Evident Smart Image Averaging (active noise reduction)
카메라 한 대에 지원하는 연결 수: 6(무선 연결 안정성 및 신뢰성은 기존의 환경적인
전파장애 및/또는 사용자 모바일 기기의 상태에 따라 손상될 수 있습니다.)
측정 및 오버레이 유형
WLAN 어댑터가 포함되지 않음(지역 영업 담당자에게 문의하십시오.)
Epview는 iOS, Android 및 Windows OS에서 사용할 수 있습니다
• 통신 프로토콜:
WLAN(IEEE 802.11n)
• 저장장치:
SD 카드(HC I, UHS-I, Class 10)
• 지원하는 모바일 기기 OS:
iOS 11 이상
Android 5.1 이상