Application Notes
Optimizing Your Oblique Observation Using Our Flexible Contrast Solution
Contrast Optimization When Using Stereo Microscopes
Optical microscopes are typically adjusted for Köhler illumination, which helps ensure even illumination of samples. However, it is difficult to apply Köhler illumination to stereo microscopes because of the stereoscopic viewing, low magnification, zoom functionality, and the wide variety of samples. Instead, oblique illumination is used with stereo microscopes as an optimized illumination method.
Challenges of the Oblique Illumination Technique
When oblique illumination is used, the observation image is affected by the (1) shadow strength (contrast level) and (2) the angle and size of the shadow. However, conventional oblique mechanisms do not allow independent adjustment of the shadow strength and the angle and
size of the shadow while maintaining even illumination for all magnifications.
Olympus’ Solution Using a LED Transmitted Light Illumination Base with Flexible Contrast Functionality
To solve this issue, Olympus developed new a contrast method using the SZX2-ILLTQ quad position LED transmitted light illumination base. This new LED illumination base enables you to optimize your observation by adjusting the contrast level and the angle and size
of the light/shadow (oblique) independently.
The solution involves a simple two step procedure:
First, you can choose between three cartridges to set the contrast level (low/standard/high). The vertical columns in Figure 1 show that the contrast increases (bottom to top) depending on the selected cartridge: COBL→COB→COBH.
Second, you can also change the angle and size of the light/shadow with 5 levels by changing oblique scales on the cartridge. The horizontal images in Figure 1 (left to right) show how this adjustment changes the light/shadow position in accordance with the oblique scale selection.
Figure 1: How the view changes depend on the difference of cartridge and oblique scale selection.
Conclusion
Products related to this application
Research Stereomicroscope System
SZX10 Stereo Microscope
The SZX10 stereomicroscope is a cost-effective system for routine research. It provides darkfield and polarization imaging, up to a 0.2 NA, 10:1 zoom ratio, and a Galilean optical system to help minimize distortion. Obtain a natural view your specimen with its excellent stereo and color representation. The wide zoom ratio provides a magnification range of 6.2x–63x with a 1X objective, and up to 123x magnification with a 2X objective.
- Versatile model
- Wide zoom ratio (10:1) and natural stereo and color representation
- Simple fluorescence observation
Research Stereomicroscope System
SZX16 Stereo Microscope
Image macro views of whole organisms to micro views of individual cell structures using the SZX16 research stereomicroscope. Its wide zoom ratio (16.4:1) enables magnifications of 7x–115x with a 1X objective and up to 230x with a 2X objective. Clearly observe fine details owing to the apochromatic optics, reducing chromatic blur for the entire magnification range, and its 0.3 numerical aperture (NA), providing a high 900 line pairs per mm resolution.
- Advanced model offering darkfield, brightfield polarization, oblique, and advanced fluorescence observation
- Ergonomically designed and provides ample space for manual and automated manipulation and injection tools
- 2 energy-efficient, long-life LED transmitted light illumination base options