血液学

要记录Giemsa染色中的细微不同,相机突出的色彩还原能力将很重要,由于100X是这方面应用常用的放大倍数,百万级像素分辨率不再是必需的。

DP75
DP28
DP23

https://main--evident-website-eds--evidentscientific.aem.live/zh/products/digital-cameras/dp75

https://main--evident-website-eds--evidentscientific.aem.live/en/camera/color/dp28/

https://main--evident-website-eds--evidentscientific.aem.live/en/camera/color/dp23/
Pixel size (μm)
3.45 x 3.45 µm
3.45 x 3.45 µm
2.4 × 2.4 μm
Number of pixels (MP)
49.1
8.9
6.4
Image Sensor
1.1 inch 12.37 megapixel color CMOS image sensor, global shutter
1 in. color CMOS
1/1.8 inch Color CMOS

Frame rate (fps)

at max resolution

*1 Max. 22 fps at 4096 × 3000 (Full Resolution)
Max. 22 fps at 2048 × 1500 (2 × 2)
Max. 44 fps at 2048 × 1500 (1 × 1)
Max. 60 fps at 1920 × 1080 (1 × 1, Full HD)
Max.32 fps at 4104 × 2174 (Full Resolution)
Max.33 fps at 3840 × 2160 (4K)
Max.33 fps at 2168 × 2168 (Square)
Max.64 fps at 1920 × 1080 (Full HD) *1
Max.45 fps at 3088 × 2076 (Full Resolution)
Max.58 fps at 2072 × 2072 (Square)
Max.60 fps at 1920 × 1080 (Full HD) *1
Connector
USB 3.1 Gen2 (Type-A)
USB 3.1 Gen1 *2
USB 3.1 Gen1 *2
Color
  • Color
  • Color
  • Color
观察方法 ?

Brightfield

荧光

Infrared

Brightfield

荧光

Brightfield

荧光

Remark
*1 帧率可能会降低,具体取决于PC机状况、显示器分辨率和/或软件。
*5 可使用USB 3.1 Gen1(5 Gbps)连接操作,但帧率会降低。
使用cellSens Entry(入门版)或DP2-TWAIN时不提供。
Focus Peaking manual focus assist
ESIA - Evident Smart Image Averaging (active noise reduction)
*USB 3.1 Gen1 is compatible with USB 3.0
Focus Peaking manual focus assist
ESIA - Evident Smart Image Averaging (active noise reduction)
​*USB 3.1 Gen1 is compatible with USB 3.0
Request a Quote
DP75
DP28
DP23

Observation Method

Flourescence

Fluorescence
Cameras must have good sensitivity and low noise because strong excitation light can damage the sample. Although the signal yield is determined by simple physics (i.e., sensitivity × number of photons), some cameras, like the DP74, have a dedicated feature to shorten and simplify the fluorescence imaging process.

Brightfield

Brightfield
Accurate color reproduction is essential. Since modern microscope illumination is very bright, it’s rare to struggle with noise in brightfield images.

Phase Contrast/DIC

Phase Contrast/DIC
For phase contrast or differential interference contrast (DIC), the DP22 and DP27 have a color mode dedicated to imaging cultured cells.

Polarization

Polarization
Many cameras designed for brightfield observation also work well for polarization due to their accurate color reproduction, such as the DP27 and SC50.

Darkfield

Darkfield
Darkfield is the second darkest microscope observation method, so cameras with high sensitivity and low noise are essential. Many of our cameras, including the DP74, UC90, and SC50, feature special noise reduction image processing for excellent darkfield images.