Case Study: Meeting the High-Accuracy Quality Control Requirements of Gravure-Cylinder Making at Think Laboratory

Gravure-Cylinder Making Must Be Controlled with an Accuracy of 1 μm or Better

Gravure-cylinder making systems are mainly used to engrave cylinders for printing labels and packaging for food, confectionary, and other commercial products. Since Think Laboratory launched its System 77 gravure-plate making machine in 1977, it has held more than 90% of the gravure plate- and cylinder-making market share in Japan. In the past, cylinders used for printing were engraved by artisans, but the widespread use of Think Laboratory’s gravure-cylinder making systems has made highly accurate and fully automated production possible at a low cost.

Illustration of a Think Laboratory FX3 automated gravure-cylinder making system installed at a customer’s site: image courtesy of Think Laboratory

Illustration of a Think Laboratory FX3 automated gravure-cylinder making system installed at a customer’s site: image courtesy of Think Laboratory

Think Laboratory’s gravure-cylinder making systems use photolithography to produce printing cylinders. The printing plates, cylindrical in shape, enable maskless exposure to light, or laser exposure. The laser provides a resolution of 3200 dpi × 12800 dpi with each beam focused on a tiny space of 2 μm × 8 μm. The required accuracy is very high, 1 μm or better. Evident’s DSX1000 digital microscope (formerly Olympus) was chosen to support this accuracy control. Shintaro Sugawara, Director and Leader of the Development Department, explains what is at stake during a quality control verification, “For example, the smallest pocket that collects ink is approximately 100 μm × 100 μm in size. The slightest difference causes variations in ink concentration. The cosmetic and automobile industries require high-quality printing that gives their products a premium feel, so even slight color variations caused by only a 1% difference in the pocket size are strictly checked.”

About Think Laboratory

Think Laboratory Co., Ltd., located in Kashiwa City, Japan, is an award-winning developer and manufacturer of the fully automated gravure-cylinder making system, one of its core products. Founded in 1966, the company is a leader in the digital printing field in Japan and around the world, offering flexible packaging solutions to over 250 companies in 38 countries. Its customers include gravure-cylinder suppliers and printing companies. In 2016, Think Laboratory integrated the DSX1000 digital microscope into its quality control (QC) process to meet its high accuracy requirements. The company is striving to achieve further degrees of accuracy to meet its customers’ requirements for high-quality printing.

Think Laboratory Co., Ltd., Kashiwa City, Japan

Think Laboratory Co., Ltd., Kashiwa City, Japan

Sample Analysis with the DSX1000 Microscope Supports Quality and Reliability

If any defect is detected in the samples printed with the cylinders manufactured using the company’s gravure-cylinder making systems, the company collects the gravure cylinder and the printing sample from the customer to analyze the cause of the defect. With its guaranteed accuracy and a 1 μm Z-axis repeatability*, the DSX1000 digital microscope plays an important role in the first step of the analysis.

For the preliminary analysis, the detected defect is observed using the DSX1000 microscope to help obtain an initial determination of the cause, which guides the subsequent analysis performed using high-magnification observation and elemental analysis with an electron microscope. The identified cause of the defect is written in a report to be submitted to the customer as feedback.

Takashi Yoshioka analyzing a printing sample using the DSX1000 microscope, the first step in the Think Laboratory’s quality control process

Takashi Yoshioka analyzing a printing sample using the DSX1000 microscope, the first step in the Think Laboratory’s quality control process

A difference of only a few micrometers in engraving on the cylinder can result in blurred words or color errors, so stringent standards are enforced for the analysis. Mr. Takashi Yoshioka of the Think Laboratory Development Department says, “Demand for high-quality printing has been increasing recently, so our quest for higher accuracy in analysis and our expectation of higher efficiency have led to the implementation of the DSX1000 microscope.”

Functions of the DSX1000 Digital Microscope that Helped Optimize the QC Process

The DSX1000 digital microscope has functions that conventional digital microscopes do not. Mr. Yoshioka, a principal user of Think Laboratory’s DSX1000 microscope, cited two functions that he was impressed with: (1) the function to switch between multiple observation methods with a single click without losing sight of the object being observed or analyzed, and (2) the multiple preview function, which enables you to compare observation method images and select the best one.

One-Button Switching between Multiple Observation Methods

Some conventional microscopes offer different observation methods, but the DSX1000 digital microscope supports up to six observation methods to inspect various samples: brightfield(BF), oblique, darkfield(DF), mix, polarization, and differential interference.

Even if the same sample is observed with the same microscope, the observation image can vary depending on the observation or illumination method. For example, BF is suitable for observing flat samples, whereas with the DF method, light that is irradiated at an incline on the sample is reflected or scattered, causing any scratch to appear bright in the dark visual field. The user can choose from among the DSX1000 microscope’s six observation methods to select the best one. The method can be changed by simply pressing a single button on the console, which is easy to use for operators.
DSX1000 console

Multiple Preview Function

By pressing a single button, you can view several sample images captured under different conditions for side-by-side comparison on the screen.

“The method that works best for each sample can be selected from the different images displayed. This function is quite useful. With conventional microscopes, observation conditions must be adjusted precisely each time to capture two types of images: an image with emphasis placed on its visual appearance to use on reports and another that is suitable for conducting a failure analysis.

The DSX1000 has eliminated the need for this precise adjustment and saved a huge amount of time spent on tasks, from running analyses to reporting. The working environment has been improved with no burden on this precise adjustment.”

You can select the observation method while viewing samples, which has made conducting observations and analyses more efficient

You can select the observation method while viewing samples, which has made conducting observations and analyses more efficient

High-Performance Lenses from an Optical-Device Manufacturer

The type of lens used in analysis work varies depending on the sample to be observed. Both Mr. Sugawara and Mr. Yoshioka were satisfied with the lenses provided by Evident, noting that as an optical-device manufacturer, the company has an extensive lineup of lenses that are very high quality and provide excellent cost performance.

To change lenses, some conventional digital microscopes require the lens to be removed to connect a new one, which can be cumbersome and time consuming. The DSX1000 digital microscope, however, has a sliding nosepiece and exclusive lens attachments, which enable you to quickly switch to the lens that suits your purpose as well as change the magnification, ranging from the macro to micro level.

Mr. Yoshioka appreciates the usability of this feature compared with conventional digital microscopes, “Being able to replace the lens instantly is convenient when we want to adjust the magnification after changing the sample. It is particularly effective in observing and analyzing various samples because conducting a low-magnification overview observation may be useful in detecting a defect quickly. With conventional digital microscopes, replacement is cumbersome and time consuming because the lens needs to be screwed into a hole, but the sliding design of the DSX1000 microscope makes lens replacement easy and eliminates the concern that the lens may be dropped.”

Lineup of 17 objective lenses Lineup of 17 objective lenses
Sliding nosepiece: lens moves back and forth Sliding nosepiece: lens moves back and forth

Replacing the lens attachment

Replacing the lens attachment

Saving Observation Parameters Saves Time

Think Laboratory’s expectations were high regarding a certain feature of the DSX1000 microscope, which is the function to retrieve observation conditions. The ability to analyze different samples using past observation conditions can be very useful. Each image file recorded in the DSX1000 microscope contains data on the parameters used for observation, such as the magnification, illumination method, and camera settings. These conditions can be retrieved by simply clicking the image. This function helps eliminate the need to search for the optimal imaging conditions each time. It also prevents variations in observation images among multiple operators as well as the failure to detect defects, enabling better analysis to be performed.

Summary

Overall, implementing the DSX1000 digital microscope into the gravure cylinder quality control process has helped Think Laboratory meet its accuracy demands and improve efficiency. Despite a slight initial hesitation about changing its manufacturer of digital microscopes, Think Laboratory proceeded with the switch based on its experience with Evident products, including its industrial videoscopes and X-ray fluorescence analyzers. The company is also very satisfied with the after-sales follow-up provided by Evident, including the series of training sessions that were provided to Think Laboratory employees after the installation.

Image of DSX1000 digital microscope

* For guaranteed accuracy, calibration by Evident or a dealer service is technician necessary. To guarantee the XY accuracy, calibration with a DSX-CALS-HR (calibration sample) is required. To issue certificates, calibration work must be undertaken by an Evident calibration service technician.
1 μm Z-axis repeatability is provided when using a 20X or higher objective.

DSX1000

Better images and results. DSX1000 digital microscopes enable faster failure analysis with accuracy and repeatability.