Application Notes

Contact Us

Application of the Z-Drift Compensation System IX-ZDC to multidimensional cell-based assay at the single cell level

Multidimensional cell-based assay at the single cell level

A cell-based assay system that facilitates efficient multi-sample data collection enables researchers to observe dose-dependent physiological activity at the single-cell level to study physiological reactions and cell response. In this type of assay, cells are typically cultured in a multiwell plate. Inverted microscopes are then used to observe physiological reactions of how cells respond when different doses of drugs are added to an individual well.

Inverted microscopes with z-drift compensation systems can perform fully automated, continuous observation over several days, which is important for monitoring cell growth or testing the toxicity of drugs. The ability to image multidimensional drug dose-dependent cell growth and intracellular physiological activity is important for advancing cell-based assays.

Using the IX-ZDC z-drift compensator to help analyze resistance of cancer cells to MEK inhibitors using FRET biosensor

1)Visualization of extracellular signal-regulated kinases (ERKs) using Förster resonance energy transfer (FRET) biosensor

The Ras-Raf-MEK-ERK signaling pathway is well known for its association with cancer development and is a target for molecular chemotherapy drugs. However, the pathway’s association with anticancer drug resistance is unclear. In order to better understand the role of the Ras-Raf-MEK-ERK signaling pathway in anticancer drug resistance, researchers at the Graduate School of Medicine, Kyoto University, Japan analyzed resistance to MEK inhibitors in multiple cancer cell lines using a FRET biosensor that enables researchers to visualize the activity of the ERK protein kinase, which is a component of the Ras-Raf-MEK-ERK signaling pathway.

Fig 1. Structure of the FRET biosensor for visualization of ERK or S6K activity

Fig 1. Structure of the FRET biosensor for visualization of ERK or S6K activity
Phosphorylation of ERK or S6K substrate in the FRET biosensor molecule causes it to intra-molecularly bind to the phosphopeptide-binding domain (WW or FHA1) resulting in an increase in the FRET efficiency between the cyan fluorescent protein (CFP) and yellow fluorescent protein (YFP).

2)Using the IX-ZDC z-drift compensator to construct a multidimensional cell-based assay system

HT-29 cells (with BRAF V600E mutation) expressing FRET (Fig. 1) were cultured in a 96-well glass plate. After adding different doses of an MEK1/2 inhibitor (AZD6244) to individual wells, a fully-motorized, inverted Evident IX Series microscope was used to continually observe the change in intracellular ERK activity and cell growth in each well for 3 days. The IX-ZDC z-drift compensator automatically adjusted the focus each time one of the wells was imaged, enabling researchers to capture images that were always in focus, even during long-term observation.

Fig 2. Using the IX-ZDC Z-drift compensator with a multidimensional cell-based assay system
Fig 2. Using the IX-ZDC Z-drift compensator with a multidimensional cell-based assay system
Bright spots in the images correspond to the nuclei of cells expressing the FRET biosensor for detecting ERK activity.
The warmer and cooler colors indicate higher and lower levels of ERK activity, respectively.

3)Quantitative analysis of MEK1/2 inhibitor dose-dependent ERK activity and cell growth rate

In order to analyze the dose-dependent response of HT-29 cells (with BRAF V600E mutation) to the MEK1/2 inhibitor (AZD6244) from the data obtained by the multidimensional cell-based assay described above (Fig. 2), the researchers generated a graph (Fig. 3) by plotting the MEK1/2 inhibitor (AZD6244) concentration on the x-axis, growth rate (/day) on the left y-axis, and ERK activity on the right y-axis (using a data set generated up to one day after the addition of the MEK1/2 inhibitor). To analyze the relationship between the MEK1/2 inhibitor dose-dependent ERK activity and the growth rate, they generated a second graph (Fig. 4) by plotting the ERK activity on the x-axis and growth rate on the y-axis. These graphs revealed that HT-29 cells exhibited almost identical IC50 values for both ERK activity and cell growth rate and that there was a linear correlation between ERK activity and cell growth rate.

Fig 3. Dose-dependent response of ERK activity and cell growth rate on the MEK1/2 inhibitor (AZD6244) in HT-29 cells

Fig 3. Dose-dependent response of ERK activity and cell growth rate on the MEK1/2 inhibitor (AZD6244) in HT-29 cells

Fig 4. Relationship between the MEK1/2 inhibitor (AZD6244) dose-dependent ERK activity and cell growth rate in HT-29 cells

Fig 4. Relationship between the MEK1/2 inhibitor (AZD6244) dose-dependent ERK activity and cell growth rate in HT-29 cells

4)MEK1/2 inhibitor dose-dependent ERK activity and cell growth rate in multiple cancer cell lines

By repeating the same analysis in cancer cell lines other than HT-29 cells, researchers found that the IC50 values of the MEK1/2 for ERK activity were similar to each other in various cancer cell lines (~0.01 μM); and in MEK1/2 resistant cancer cell lines (KRas-mutant cell lines), the IC50 for the cell growth rate was more than 10 times higher than the IC50 for ERK activity, resulting in a nonlinear correlation between ERK activity and cell growth rate.

This study required large volumes of imaging data, and the efficient analysis of resistance to the MEK inhibitor in cancer cells would not have been possible without the IX-ZDC z-drift compensator for the inverted IX Series microscope.

Fig 5. Comparison of IC50 values of the MEK1/2 inhibitor (AZD6244) for ERK activity and cell growth rates in multiple cancer cell lines

Imaging conditions
Microscope: Motorized inverted IX Series microscope.
Z-drift compensation system: IX-ZDC
Objective: UPLSAPO20X, dry
Microplate: 96-well glass microplate

ConclusionIX-ZDC z-drift compensator supports multidimensional cell-based assays

Evident’s IX-ZDC z-drift compensator and the motorized, inverted IX Series microscope enable the material in individual wells within a microplate to be imaged clearly for experiments lasting multiple days. With the autofocus function, a 96-well plate can be completely imaged in about 2 minutes,* supporting a highly precise and rapid cell-based assay.

*For serial imaging of one spot in each well of a 96-well plate with a 30 ms exposure time.

Movie of UCPLFLN20XPH to multidimensional cell-based assay at the single cell level

This application note was prepared with the help of:
Dr. Naoki Komatsu, Assistant Professor, Laboratory of Bioimaging and Cell Signaling, Graduate School of Biostudies, Kyoto University, Japan and Dr. Kazuhiro Aoki, Designated Associate Professor, Imaging Platform for Spatio-Temporal Information, Graduate School of Medicine, Kyoto University, Japan.

For more details on the study in this application note, please see:
Komatsu, N., Y. Fujita, M. Matsuda, and K. Aoki. "mTORC1 upregulation via ERK-dependent gene expression change confers intrinsic resistance to MEK inhibitors in oncogenic KRas-mutant cancer cells." Oncogene 34, no. 45 (2015): 5607–5616


https://main--eds-evident-website--evident-scientific.aem.live/en/advanced-imaging-solutions/spinsr10/

Spinning Disk Confocal Super Resolution Microscope

SpinSR10

  • Live cell super resolution imaging
  • Observation at depth
  • A flexible system that helps simplify your research

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/inverted/ix83/

The fully-motorized and automated inverted microscope system

IX83

  • Unique deck system
  • Fully-motorized system
  • System solutions

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/inverted/ixplore-live/

Live Cell Imaging Microscope System

IXplore Live

Designed to reduce photobleaching and phototoxicity, the IXplore Live system is optimized for physiological experiments involving live cell and tissue observation. Offering precise environmental control and enhanced rigidity, it supports long-term cell viability and stability for time-lapse imaging applications, such as in cancer, stem cell, and brain research.

  • Maintain focus accurately and reliably in time-lapse experiments with TruFocus™ Z-drift compensation system
  • Discover the real morphology of your cells with Evident silicone immersion optics
  • Real-time controller helps limit cell disturbance, enabling physiologically relevant data

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/inverted/ixplore-pro/

Automated Microscope System

IXplore Pro

The IXplore Pro automated system acquires panoramic, multichannel images without a complex workflow. Easing experiment setup, the Graphical Experimental Manager offers fully automated multidimensional observation capabilities. The microscope’s high-precision ultrasonic stage, automated focusing, and bright, uniform fluorescence illumination facilitate image stitching applications.

  • Automated multidimensional observation (X, Y, Z, T, wavelength, and positions)
  • Boost your statistics with multiwell plate screening
  • Acquire fluorescence panoramic images of large samples, such as brain slices
  • Create 3D optical sections and enhance resolution with TruSight™ deconvolution

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/inverted/ixplore-spin/

Confocal Imaging Microscope System

IXplore Spin

The IXplore Spin system features a spinning disk confocal unit that enables fast 3D image acquisition, a large field of view, and prolonged cell viability in time-lapse experiments. Researchers can use it to perform rapid 3D confocal imaging with high resolution and contrast at greater depths for imaging into thicker samples. The spinning disk also helps to cut down on photobleaching and phototoxicity of samples upon excitation.

  • Real-time controller (U-RTCE) helps optimize the device’s speed and precision during automated acquisition
  • TruFocus™ Z-drift compensation system maintains focus for each frame
  • Precise 3D imaging with improved light collection using X Line™ objectives
  • Upgrade to the IXplore SpinSR super resolution system as your research progresses

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/inverted/ixplore-spinsr/

Super Resolution Microscope System

IXplore SpinSR

The IXplore SpinSR system is our confocal super resolution microscope optimized for 3D imaging of live cell specimens. Like the IXplore Spin system, it has a spinning disk system for fast 3D imaging while limiting phototoxicity and bleaching. However, it achieves super resolution images down to 120 nm XY and enables you to switch between widefield, confocal, and super resolution with the click of a button.

  • Sharp, clear super resolution imaging down to 120 nm XY, owing to Evident Super Resolution (ESR)
  • Prolonged cell viability in confocal time-lapse imaging due to less phototoxicity and bleaching
  • Use two cameras simultaneously to achieve fast, two-color super-resolution imaging
  • Super resolution imaging with the world’s first plan apochromat objectives with a numerical aperture (NA) of 1.5*

* As of November 2018. According to Olympus research.

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/inverted/ixplore-tirf/

TIRF Imaging Microscope System

IXplore TIRF

For membrane dynamics, single-molecule detection, and colocalization experiments, the IXplore TIRF system enables sensitive simultaneous multicolor TIRF (total internal reflection fluorescence) imaging for up to four colors. Evident’s cellTIRF system provides stable motorized individual laser-angle control, providing equal evanescent wave penetration for high-contrast, low noise images. Our TIRF objectives feature high SNR, high NA, and correction collars to adjust for cover glass thicknesses and temperature.

  • Exact colocalization of up to four markers thanks to individual penetration depth control
  • Take advantage of Evident’s TIRF objective with the world's highest NA of 1.7*
  • Intuitive setup of complex experiments with the Graphical Experiment Manager (GEM), cellFRAP, and U-RTCE

* As of July 25, 2017. According to Olympus research.

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/objectives/ucplfln/

Semi-Apochromat Objectives for Cell Culture

UCPLFLN/LUCPLFLN

Enabling tissue culture observation through bottles and dishes, these universal semi-apochromat objectives feature a long working distance and high contrast and resolution. Providing flat images and high transmission up to the NIR region, they are well suited for brightfield, DIC, and fluorescence observation.

  • Provides long working distance, universal objectives with excellent contrast and resolution in brightfield, DIC and fluorescence observations
  • Displays flat images from high transmission factors up to the near-infrared region of the spectrum
  • Dedicated to tissue culture observations through bottles and dishes

Learn More


https://main--eds-evident-website--evident-scientific.aem.live/en/microscopes/inverted/ix83/TruFocus/

Z Drift Compensator

TruFocus (IX3-ZDC2)

  • Always in Focus
  • Designed for Ease-of-use
  • Dedicated to Live Cell Imaging
  • High-Precision, Multi-Area Imaging with cellSens Software

Learn More