Application Notes

Contact Us

Laser Groove Profiling in Semiconductor Wafers Using the OLS5000 Laser Confocal Microscope

Introduction

In the semiconductor integrated circuit manufacturing process, a silicon wafer is diced to separate it into individual dies that are then assembled onto lead frames and encapsulated into electronic chips.

The conventional dicing process uses a very sharp blade to cut through the silicon wafer to separate the dies. However, blade dicing is problematic. In particular, the blade can stress the dies and wafer as a whole no matter how sharp it is. The need to achieve increasingly smaller and thinner dies and the migration to low-k dielectric and copper materials have necessitated the addition of laser surface grooving prior to the blade dicing process to overcome topside delamination and sub-surface cracking of the dielectric material.

Process of Laser Grooving

Laser grooving is a two-step process. First, a laser is used to isolate the edge of the die by creating ‘train track’ grooves through the wafer’s surface layers and just into the silicon layer. Next, subsequent laser passes remove the material in the ‘street’ between the train tracks. Once the streets have been cleared, the wafer is diced with a blade. Thanks to this laser grooving process, the blade only has to cut through the silicon and not any of the surface materials.

laser grooving process

Measuring the Profile of Laser Grooves Using a Laser Confocal Microscope

The advantages of laser grooving have made it the preferred semiconductor manufacturing process for wafer dicing. However, laser grooving also has its own challenges. The laser system is complex, and it needs to be accurately positioned over the wafer to ensure that it creates grooves along the correct profile on the die streets. The groove itself must be extremely precise and conform to the profile and tolerance set by the manufacturer. To help ensure that their laser system is set up correctly, manufacturers need a tool that enables them to measure the profile of the laser grooves to check whether they meet the specified tolerance.

The Evident OLS5000 laser scanning confocal microscope (formerly Olympus OLS5000) is well suited to provide accurate profile measurements of laser grooves. It can provide the quantitative data required to check that the grooves meet manufacturer tolerance standards. The microscope offers fast, precise imaging and a large 300 mm × 300 mm (roughly 12 in. x 12 in.) motorized stage that readily accommodates 12-inch wafers. The microscope software’s acquisition and analysis functions make it simple for operators to measure the depth and width of laser groove profiles.

Olympus OLS5000

Different stages

Advantages of Using the OLS5000 Microscope for Laser Grooving Quality Assurance

  1. The microscope offers fast, precise imaging and a large 300 mm × 300 mm (roughly 12 in. x 12 in.) motorized stage movement that readily accommodates 12-inch wafers.
  2. Programmable multi-area acquisition feature enables automatic multipoint acquisition of laser grooves on a wafer.
  3. The combination of the microscope’s 405 nm laser source, 0.8 nm optical z scale, 4K scanning technology, and dedicated LEXT™ objective lenses provide accurate 3D profiling of laser grooves during the acquisition process.
  4. Users can create an analysis template for automatic measurement of the width and depth of laser groove 3D profiles.
  5. All of the measurement data can easily be complied into a single, comprehensive quality report.
Laser groove profile measurements

Products Used for This Application

LEXT OLS5500

Hybrid 3D Optical Profilometer

  • Traceable surface measurements from the nanometer to micrometer scale
  • Laser scanning microscopy (LSM), white light interferometry (WLI), and focus variation microscopy (FVM) in one award-winning platform
  • First 3D optical profilometer to offer guaranteed accuracy and repeatability* for both LSM and WLI measurements
  • WLI mode delivers up to 40x faster measurement throughput than conventional LSM
  • Exceptional precision across surfaces with in-house engineered optics
  • Intuitive interface and smart automation streamline operation for users of all levels
  • AI-enhanced and high-throughput workflows with PRECiV™ software integration

*Based on Evident’s internal research as of October 2025. The guaranteed accuracy and repeatability apply only if the device has been calibrated according to the manufacturer’s specifications and is in defect free condition. Calibration must be performed by an Evident technician or an Evident-authorized specialist.

Learn More

LEXT OLS5100

The LEXT™ OLS5100 laser scanning microscope combines exceptional accuracy and optical performance with smart tools that make the system easy to use. The tasks of precisely measuring shape and surface roughness at the submicron level are fast and efficient, simplifying your workflow and delivering high-quality data you can trust.