Total Support for Assisted Reproductive Technology (ART) Research

microscopy solutions for assisted reproductive technology (ART) research applications range from stereoscopic microscopes used for oocyte cleaning, oocyte freezing, and embryo thawing observation to upright microscopes for sperm observation, to inverted microscopes that support ICSI/IMSI workflow and additionally embryo manipulation using lasers.

Sperm Observation

System Microscope BX53*
Biological Microscope CX43*

Sperm is typically observed by contrasting bright and dark on the sample, using phase contrast observation under an upright microscope. A common limitation of these microscopes is that their light source is not bright enough to properly verify sperm mobility. Evident’ BX53 microscope system has a high-luminosity LED that enables users to clearly observe the mobility of sperm. In addition, since the LED light source generates low heat, damage to the sample is diminished. The ergonomic observation tubes and negative phase contrast objective for longer and clearer sperm observations help ensure comfortable microscope operation. The CX43 biological microscope, which is an entry-level model, is designed with low stage so users can keep their arms on the desk, helping reduce fatigue during long observation sessions. It is compact model with a small footprint to save space in the lab.

Comment by Kato Ladies Clinic

We use the upright BX53 microscope mainly for sperm counting and morphological observation. Sperm are counted by phase contrast observation using the SMAS (sperm motility analysis system). Evident upright microscopes have a sufficient amount of light that does not interfere with measurement. For sperm morphology evaluation, unstained specimens are prepared by our own method and observed using 600X dry objectives. The outline of the sperm can be clearly seen, and the contrast adjustment enables us to observe and evaluate the shading of the sperm head at the same image-quality level as stained specimens. Furthermore, incorporating differential interference contrast (DIC) observation increases the clarity and improves the accuracy of sperm morphology evaluation.

Research content of this application note was prepared with the collaboration of the following user:
Dr. Kazuo Uchiyama
Kato Ladies Clinic

ICSI/IMSI

IX3-ICSI/IMSI
IX3-ICSI/IMSI
Inverted Microscope IX3-ICSI/IMSI

When performing intracytoplasmic sperm injection (ICSI) in an oocyte, polarization observation should be used to observe the spindle to confirm that it is in the metaphase II stage. This indicates it has become a mature oocyte, and also helps to make sure that it is in the right position to avoid damage during injection. Evident’ IX3 inverted microscope series with its polarization technology enables users to clearly observe the appearance of the spindle. Also, Evident' relief-contrast allows the observation of 3-dimentional oocytes in plastic dishes, which enables users to check the condition of oocyte zona pellucida.

During ICSI and IMSI, multiple observation methods and lens magnifications are used, making microscope operation more complex and less efficient and increasing the level of stress and fatigue for the user. The Evident IX3 semi-motorized system has an ICSI-dedicated hand switch enabling the user to instantly change the observation method and magnification to suit each step in process with the touch of a button, saving time and reducing fatigue. This functionality can even eliminate certain steps of the traditional process. It also means that users don't have to take their eyes off the eyepieces, and consequently can focus on delicate manipulator operations.

With IMSI, which is a method of injecting sperm selected by morphological characteristics into oocytes, the shape, size, and number of vacuoles on the sperm head are confirmed at high magnification. This is supported by the IX3 series’ differential interference contrast (DIC) observation.


ICSI (Relief contrast) Spindle (Polarizing observation) Sperm (DIC)

Comment by Kato Ladies Clinic

Sperm used for ICSI are selected by IMSI using high-magnification differential interference contrast observation. Since implementing this method, the probability of selecting normal morphological sperm has increased compared with conventional observation using 200X or 400X objectives. Correctly choosing sperm with the normal morphology reduces the DNA fragmentation rate which may be beneficial for patient safety, for example, by lowering the miscarriage rate.

Visualization of the spindle by polarizing observation is effective for correctly measuring the timing to perform ICSI. Even when the oocyte has extruded the first polar body, successful fertilization is less likely if ICSI is performed in an oocyte without meiotic spindle visualization. Since we are able to visualize the meiotic spindle at the time of ICSI, our fertilization rate has significantly improved.
The Evident IX83 inverted microscope can seamlessly perform a series of observations with differential interference contrast (DIC), polarization, and relief contrast, and the IX73 semi-motorized model can switch between polarization and relief contrast by the remote controller. The Evident IX83 and IX73 are easy-to-use devices for users.

Fertilization Check of Oocytes and Embryos

SZX16
Fertilized Embryo
Research Stereo Microscope System SZX16*
Fertilized Embryo

Oocyte cleaning, fertilization checks, embryo grade confirmation, and observation during oocyte freezing and thawing are performed under a stereo microscope. Since it is difficult to see the oocyte and embryo, it takes time to find and judge the maturity level, placing a burden on the user. To help ensure the user’s comfort, Evident SZX stereo microscope series has adjustable eye points and uses an observation tubes with a convergence angle, which alleviates eye fatigue. There are also several ergonomic accessories available for the series, such as an observation tube that can incorporate a clean bench because the mounting position of the main body and eyepiece is longer than usual.

In addition, the SZX2-ILLTQ/S transmitted light illumination base can provide appropriate contrast and uniform illumination from low to high magnification, so the condition of oocytes and embryos can be checked quickly and work efficiency can be improved. Evident’ stereo microscope SZX series provides a comfortable microscope workspace and contributes to reducing user's fatigue and improving work efficiency. SZX2-ILLTQ/S also enables users to choose the appropriate observation method and contrast from 9 types of cartridges, depending on the application and user's preference.

Comment by Kato Ladies Clinic

Stereo microscopes are used in a wide range of applications such as oocyte denuding, oocyte and embryo observation, and vitrification-warming. Brightfield, oblique, and darkfield observation methods are used according to the laboratory procedures. Evident' stereo microscope enables you to quickly switch all observation areas from 0.7X to 11.5 X magnification in focus, which improves work efficiency. Since optimal contrast can be selected from three fine-adjustable contrast levels, the observation of oocytes and embryos has become much easier.

We use a 0.8X objective lens and combine an ergonomic trinocular barrel (SZX-LTTR) with an intermediate magnification of 1.25x to ensure a large working space under the objective lens. As a result, work efficiency for oocyte and embryo observation and manipulation has improved. In addition, since the light source uses LEDs, it is less likely to deteriorate and is maintenance-free, which is also highly valued.

* For research use only.

Produits utilisés pour cette application

Plateformes IICS/IMSI

IX3-ICSI/IMSI

Le système IX3-ICSI est conçu pour faciliter l’utilisation de l’injection intracytoplasmique de spermatozoïdes (IICS) dans le cadre du processus de fécondation in vitro (FIV). La méthode de contraste de relief d’Evident permet l’observation d’ovocytes en 3D dans des boîtes de Petri en plastique pour vérifier l’état de la zone pellucide. Le système semi-motorisé IX3 est doté d’une commande manuelle dédiée à l’ICSI qui permet de changer instantanément la méthode d’observation et le grossissement d’une simple pression sur un bouton. Utilisez la méthode de polarisation pour observer le fuseau mitotique et sa position pour vérifier la maturité des ovocytes et éviter tout dommage pendant l’injection et la méthode de contraste interférentiel différentiel (CID) pour effectuer l’injection intracytoplasmiques de spermatozoïdes morphologiquement sélectionnés (IMSI).

  • Optimisé pour assurer une procédure d’ICSI plus fluide
  • Vérification aisée de l’état des ovocytes grâce à la visualisation des fuseaux mitotiques
  • Étapes d’ICSI simplifiées grâce au fonctionnement motorisé

En apprendre plus

Microscope à fluorescence semi-motorisé

BX53

  • Éclairage LED haute luminosité révélant les couleurs naturelles
  • Concept modulaire permettant la motorisation de composants individuels
  • Acquisition simple d’images en fluorescence multicolores

En apprendre plus

Microscope biologique

CX43

  • Conception ergonomique
  • Idéal pour les utilisations diversifiées
  • Système d’éclairage à LED à longue durée de vie

En apprendre plus

Système de stéréomicroscope destiné à la recherche

SZX16

Prenez des images macro d’organismes entiers ou des images micro de structures cellulaires individuelles avec le stéréomicroscope de recherche SZX16. Son grand rapport de zoom (16,4:1) permet des grossissements de 7x à 115x avec un objectif 1X et de jusqu’à 230x avec un objectif 2X. Observez clairement des détails fins grâce à l’objectif apochromatique, qui réduit le flou chromatique sur toute la plage de grossissement, avec une ouverture numérique (ON) de 0,3 assurant une résolution élevée de 900 paires de lignes par millimètre.

  • Modèle avancé permettant l’observation en fond noir, en fond clair, en lumière polarisée, en oblique et de fluorescence avancée
  • Conception ergonomique avec beaucoup d’espace pour les outils de manipulation et d’injection manuels et automatisés
  • Deux options de base d’éclairage en lumière transmise à DEL à faible consommation électrique et longue durée de vie

En apprendre plus

Sources de lumière

Nous proposons une large gamme de sources de lumière optimisées pour vos applications d’imagerie en fond clair ou de fluorescence.

En apprendre plus

Système d’éclairage U-FLLED LED : image 1 sur 1

U-FLLED

Source lumineuse à LED compacte à montage direct conçue pour l’imagerie fluorescopique de routine sur microscopes manuels et semi-motorisés. Grâce à son refroidissement passif sans ventilateur et à ses canaux d’excitation modulaires, l’U-FLLED offre un éclairage stable et uniforme pour les échantillons fixés et les flux de travail quotidiens sans augmenter la complexité du système.

  • Éclairage LED à montage direct pour configurations intégrées au microscope.
  • Canaux d’excitation modulaires pour fluorochromes courants
  • Fonctionnement silencieux et sans ventilateur pour l’imagerie fluorescopique de routine

En apprendre plus