Sectioning Analysis for Ball Grid Array (BGA) Surface Mounting of Semiconductor Package using the Evident LEXT5000 (Previously Known as Olympus OLS5000) Laser Confocal Microscope
Background
The growing demand for small, high-speed mobile electronic devices with versatile features has caused a corresponding increase in the demand for high-density electronic components built on printed boards. This demand changed the way high-density components are made. Previously, integrated circuit (IC) components were manufactured using surface mount techniques, such as quad flat package (QFP) and small outline package (SOP). Increasingly, these components are produced using chip-on-board (COB) techniques where IC chips are mounted directly onto printed circuit boards. One popular method that is well-suited to manufacturing high-density components is a ball grid array technique called ‘flip chip,’ where bumps formed on a chip are connected directly to a printed board. This interface must be inspected to ensure that the connections are secure.
To analyze the interface, the chip is cut so that the connections can be directly observed using an optical microscope. However, the cut chip is polished before it can be viewed, and this process introduces fine surface irregularities which can make observation difficult. When this happens, manufacturers typically rely on an expensive electron microscope to make their inspections. The Evident LEXT provides a fast and cost-effective solution to BGA inspection without the use of an electron microscope.
The Evident solutions
The Evident LEXT 3D measuring laser microscope features extended focal imaging (EFI), which uses the fine focus adjustment to combine many in-focus images from along the Z-axis. This results in an image of the entire field of view in focus. The LEXT has a minimum resolution of 0.12 μm. Using the LEXT, you will acquire clear images of surfaces containing fine irregularities that are similar to those you could obtain by using an electron microscope. In addition, the LEXT is capable of multicolor observations.
Features of the product
The Evident LEXT features ultra-high-resolution combined with high pixel density (Figure 1). The EFI function enables you to bring the entire field of view into focus for easy inspection. The LEXT employs a variety of microscopy and image processing techniques that gives you the ability to highlight a feature point on the object being observed and make accurate measurements.
Image
Figure 1: A high-resolution image taken using the LEXT
应用所使用的产品
LEXT OLS5500
全新一代 精准测量 激光共聚焦显微镜
- 从纳米级至微米级的可追溯表面测量
- 一个获奖平台融合了激光扫描显微镜(LSM)、白光干涉仪(WLI)和焦点变化显微镜(FVM)技术
- 一款能够同时为 LSM 和 WLI 测量提供准确性和重复性* 保证的显微成像平台
- WLI 模式的测量通量比我们的传统 LSM 提高达 40 倍。
- 采用自主设计的光学系统,为表面测量提供卓越的测量精度
- 直观界面结合智能自动化,满足不同经验级别用户的操作需求
- 集成 PRECiV™ 软件的 AI 增强型高通量工作流程
* 根据 Evident 截至 2025 年 10 月的内部研究结果。设备必须按照制造商的规格进行校准并且不存在任何缺陷时,方可保证测量的准确性和可重复性。 校准必须由 Evident 的技术人员或 Evident 授权的专家执行。
LEXT OLS5100
具有出色精度和光学性能的LEXT™OLS5100激光扫描显微镜配备了让系统更加易于使用的智能工具。其能够快速高效完成亚微米级形貌和表面粗糙度的精确测量任务,既简化了工作流程又能让您获得可信赖的高质量数据。