Measuring the Height of Microscopic Bumps for Flip Chip Bonding

Mounting integrated circuit (IC) chips on a printed circuit board (PCB) using a grid of microbump solders is a technique called flip chip bonding. To ensure a proper connection between the IC and PCB, the height of the bumps must be uniform. For this reason, the bump height must be measured quickly and accurately during production.

Measuring the Height of Microscopic Bumps for Flip Chip Bonding

Measuring the Height of Microscopic Bumps for Flip Chip Bonding

Evident' Solution: Height Measurement Using the OLS5000 Industrial Microscope

The LEXT OLS5000 3D laser scanning microscope can provide precise and fast height measurement at the microscopic level thanks to a range of innovative features:

(1) With the microscope’s unique PEAK algorithm, it takes only about 10 seconds to acquire data in a 649 µm × 640 µm area of bumps 20 µm high.

(2) The system has a multiple-area data acquisition function, which enables you to specify multiple areas and obtain the data of those areas simultaneously.

Olympus' Solution: Height Measurement Using the OLS5000 Industrial Microscope

(3) By setting the height reference plane for the image to be acquired, you can measure the heights of all the bumps within the field of view at one time.

Setting the reference plane for height measurement.

Setting the reference plane for height measurement.

All the bump heights within the field of view can be automatically measured.

All the bump heights within the field of view can be automatically measured.

(4) All the details and steps of an operation you have performed can be stored as a template when producing a report. When repeating a measurement, you can reload the template to obtain a report analyzed using the same procedure parameters.

(5) Typical bump measuring systems inspect bumps at high speed, but they do not work well for very fine microscopic bumps. The OLS5000 microscope helps ensure accuracy and reproducibility suitable for the height measurement of microscopic bumps.

相关产品

LEXT OLS5500

全新一代 精准测量 激光共聚焦显微镜

  • 从纳米级至微米级的可追溯表面测量
  • 一个获奖平台融合了激光扫描显微镜(LSM)、白光干涉仪(WLI)和焦点变化显微镜(FVM)技术
  • 一款能够同时为 LSM 和 WLI 测量提供准确性和重复性* 保证的显微成像平台
  • WLI 模式的测量通量比我们的传统 LSM 提高达 40 倍。
  • 采用自主设计的光学系统,为表面测量提供卓越的测量精度
  • 直观界面结合智能自动化,满足不同经验级别用户的操作需求
  • 集成 PRECiV™ 软件的 AI 增强型高通量工作流程

* 根据 Evident 截至 2025 年 10 月的内部研究结果。设备必须按照制造商的规格进行校准并且不存在任何缺陷时,方可保证测量的准确性和可重复性。 校准必须由 Evident 的技术人员或 Evident 授权的专家执行。

了解更多

LEXT OLS5100

具有出色精度和光学性能的LEXT™OLS5100激光扫描显微镜配备了让系统更加易于使用的智能工具。其能够快速高效完成亚微米级形貌和表面粗糙度的精确测量任务,既简化了工作流程又能让您获得可信赖的高质量数据。

了解更多