General Biology

Contact us

Inserting image...

General Biological Research

For customers who need a camera capable of both fluorescence and brightfield, we offer the DP80 and DP74 cooled color cameras.

DP28

DP23

SC180

LC35

EP50

Pixel size (μm)
3.45 x 3.45 µm
2.4 × 2.4 μm
1.25 × 1.25 μm
2.64 × 2.64 µm
2.4 × 2.4 μm
Number of pixels (MP)
8.9
6.4
18
5
Image Sensor
1 in. color CMOS
1/1.8 inch Color CMOS
1/2.3 in. color CMOS
1/2.5 in. color CMOS
1/1.8 inch Color CMOS

Frame rate (fps)

at max resolution

Max.32 fps at 4104 × 2174 (Full Resolution)
Max.33 fps at 3840 × 2160 (4K)
Max.33 fps at 2168 × 2168 (Square)
Max.64 fps at 1920 × 1080 (Full HD) *1
Max.45 fps at 3088 × 2076 (Full Resolution)
Max.58 fps at 2072 × 2072 (Square)
Max.60 fps at 1920 × 1080 (Full HD) *1
10.5 fps at 4,912 × 3,684 pixels (4:3)
23.6 fps at 2,456 × 1,842 pixels (4:3)
45 fps at 1,224 × 920 pixels (4:3)
14 fps at 4,912 × 2,762 pixels (16:9)
25 fps at 3,840 × 2,160 pixels (4K UHD 16:9)
31 fps at 1,920 × 1,080 pixels (Full HD 16:9)
59 fps at 1,224 × 688 pixels (16:9)
Up to 19 fps at 2,160 × 1,620 pixels (@ full resolution)
Up to 25 fps at 1920 × 1080 pixels (@ full HD)
Up to 40 fps at 1,296 × 972 pixels (@ fast mode)
Up to 30 fps (Full HD 16:9 on PC, 1920 × 1080 pixels)
Up to 60 fps (HDMI Output, 1920 × 1080 pixels)
Up to 25 fps (WLAN Output, 1920 × 1080 pixels)
Connector
USB 3.1 Gen1 *2
USB 3.1 Gen1 *2
USB 3.0
USB 3.1 Gen1 Type-C
HDMI, WLAN (using the WLAN adaptor), Ethernet (using the USB-to-Ethernet adaptor)
Color
Color
Color
Color

Color

WLAN

Observation Method

Brightfield

Fluorescence

Brightfield

Fluorescence

Brightfield
Brightfield
Remark
Focus Peaking manual focus assist
ESIA - Evident Smart Image Averaging (active noise reduction)
*USB 3.1 Gen1 is compatible with USB 3.0
Focus Peaking manual focus assist
ESIA - Evident Smart Image Averaging (active noise reduction)
*USB 3.1 Gen1 is compatible with USB 3.0
Focus Peaking manual focus assist
ESIA - Evident Smart Image Averaging (active noise reduction)

Supported number of connections to one camera: 6 (The wireless connection stability and reliability can be compromised by existing
environmental radio interference and/or the condition of users’ mobile devices.)
Measurement and overlay type
WLAN adaptor not included (Please contact your local sales representative.)
EPview is available for iOS, Android, and Windows OS

• Communication Protocol:
WLAN (IEEE 802.11n)

• Storage:
SD card (HC I; UHS-I, Class 10)

• Supported mobile device OS:
iOS 11 and later
Android 5.1 and later

Request a Quote
DP28
DP23
SC180
LC35
EP50