Microscope Solutions for Lithium-Ion Battery Manufacturing

Microscope Solutions for
Lithium-Ion Battery Manufacturing

Electrode Manufacturing Process

Apply the electrode material to the metal foil, which is used as a current collector. After pressing it, cut the metal foil into the size of one electrode.

Inspecting the Burrs (Projections) on the Electrode Sheet

If there are burrs (projections) on the current collector or electrodes, there is a risk of breaking through the separator and causing a short circuit, which can lead to damage, fire, or explosions. For this reason, the inspection of burrs using a microscope is required.

Our Solution

Our DSX series digital microscope can quickly and easily inspect burrs on an electrode sheet.

DSX series digital microscope

DSX series digital microscope

View Product Details

Current collector and electrodes

Current collector and electrodes

Inspecting the Electrode Cross Section

The power generation efficiency improves if the electrode material and the current collector are in close contact with each other. Inspectors must observe the cross section to check the placement of the materials.

Our Solution

Set the electrode vertically and observe the interface between the electrode material and current collector using our DSX series digital microscope. If the dimensions of the electrodes are large, we recommend our STM7 measuring microscope.

DSX series digital microscope

DSX series digital microscope

View Product Details

STM series measuring microscope

STM series measuring microscope

View Product Details

Cross section of electrode

Cross section of electrode

Measuring the Surface Roughness of the Current Collector

The surface of the current collector is processed to enhance the movement of the electrodes between the collector and the active material. Inspectors must measure the collector's surface roughness to help ensure that the battery works properly.

Our Solution

Our OLS series laser scanning microscope can measure the current collector's surface roughness to make sure that the roughness f alls within a certain range. This nondestructive method can measure without making defects on the surface.

OLS series laser scanning microscope

OLS series laser scanning microscope

View Product Details

Surface roughness measurement acquired with the OLS5000 laser scanning microscope

Surface roughness measurement acquired with the OLS5000 laser scanning microscope

Application Notes

Explore related applications:

Measuring the Surface Roughness of Lithium-Ion Battery Electrode Collectors

Measuring the Surface Roughness of Lithium-Ion Battery Electrode Collectors

Read More

Inspecting the Surface Roughness of the Electrode

A film called a separator is placed between the anode and cathode. Many tiny holes are opened in the separator, and the lithium ions move between the anode and cathode to generate electricity. To maintain proper adhesion with the separator, it is critical to control the surface roughness of the electrode.

Our Solution

Our With our OLS series laser scanning microscope can measure the surface roughness of the electrode. This nondestructive method can measure without making defectson the surface.

OLS series laser scanning microscope

OLS series laser scanning microscope

View Product Details

Measurement of anode surface roughness

Measurement of anode surface roughness

Application Notes

Explore related applications:

Measuring the Roughness of Lithium-Ion Battery Electrodes Using a Laser Microscope

Measuring the Roughness of Lithium-Ion Battery Electrodes Using a Laser Microscope

Read More

Analyzing Metal Contamination

Unexpected fires or explosions from lithium-ion batteries overheating is a major safety concern. One of the main causes of a lithium-ion battery self-igniting is an electrical short circuit due to metal contamination mixed in during the manufacturing process. Due to this risk, contamination analysis is a critical part of lithium-ion battery manufacturing.

Our Solution

Easily analyze metal contamination using our EVIDENT CIX100 cleanliness inspector.

OLYMPUS CIX100 cleanliness inspector

EVIDENT CIX100 cleanliness inspector

View Product Details

Measurement of anode surface roughness

Application Notes

Explore related applications:

Measuring the Roughness of Lithium-Ion Battery Electrodes Using a Laser Microscope

Metal Contamination Analysis of Automotive Lithium-Ion Batteries using the EVIDENT CIX100 Technical Cleanliness Inspection System

Read More