cellSens Microscope Imaging Software
Providing intuitive operations and a seamless workflow, cellSens software’s user interface is customizable so you control the layout. Offered in a range of packages, cellSens software provides a variety of features optimized for your specific imaging needs. Its Graphic Experiment Manager and Well Navigator features facilitate 5D image acquisition. Achieve improved resolution through TruSight™ deconvolution and share your images using Conference Mode.
The cellSens software package is not for clinical diagnostic use.
-
Software Downloads:
cellSens Imaging Software
Intuitive Operation. Seamless Workflow.
The Evident cellSens platform gives you full control over the display and placement of icons, toolbars, and controls, enabling the software to grow and adapt to meet your evolving research needs.
cellSens Packages
cellSens Entry
cellSens Entry is the ideal stepping stone for researchers wanting to move into digital image acquisition and documentation, providing all the tools needed for simple image acquisition.
cellSens Standard
The cellSens Standard takes acquisition beyond a single image, with advanced image capture processes (e.g. time lapse) and control of motorized and encoded microscope components.
cellSens Dimension
cellSens Dimension is the most versatile cellSens software package, featuring fully automated image acquisition, powerful analysis tools, and a wide range of additional benefits.
5D Experiment Acquisition
Acquire images in five dimensions using tools like the Graphic Experiment Manager (GEM) and Well Navigator that help you visualize your data acquisition in a user-friendly way.
Graphic Experiment Manager (GEM)
Dimension
The GEM is a flexible drag-and-drop interface that enables you to build simple or complex experiments within cellSens software. Combine actions within specialized frames to dictate the order and priority of automation and interact with the system during long-term, time-lapse acquisitions without terminating the experiment. To increase efficiency, you can define macro functions, such as executing deconvolution processing in the GEM.
Process Manager
Dimension + Standard
The Process Manager makes it easy to capture multichannel and time-lapse images with just a few clicks. Z-stack imaging is also possible when using a cellSens Dimension license.
Dimension + Multiposition
Standard + Multiposition
Use the optional Multiposition solution to automatically capture multipoint and large-area images when using a motorized stage. You can also navigate around your sample by simply clicking on a point in an image with the Stage Navigation tool.
Well Plate Navigation
Dimension + Multiposition + Well Plate Navigator
The Well Plate Navigator automatically scans and acquires images from standard and customized well plate formats. All acquired images, sample positions, and user comments can be saved into a structured database for rapid centralized access. Apply unique multidimensional acquisition settings to a single well or multiple selected wells in one step, so you can execute multiple experiments within a well plate in support of complex experiments.
Database
Dimension + Database Core or Database Client
Standard + Database Core or Database Client
The Database Core solution enables you to create user-defined databases with full access control, which can be shared across a network. An interactive query tool makes it easy to find the desired images, associated image properties, user comments, and all related files, like spreadsheets, with automatic preview of the found images. With the Database Client solution, you can conveniently read and write to the shared database from many different stations.
Dimension + Multiposition + Well Navigator +
Database Core or Database Client
When used with the Well Navigator solution, the Database solution makes viewing and analyzing well plate images with a large amount of data more efficient. Simply click on icons for image information, such as the date, file name, or well plate number, and any selection of captured images can be viewed for further analysis. Together, these tools enable you to view captured images and continuously analyze selected images (using Batch Macro commands) using the well plate interface.
Real-Time Panoramic Imaging
Dimension
Standard + Manual Process
Create stitched images in real time with the Manual Process solution. Manual Process Control makes it simple to move around your sample using a manual stage while the software records and stitches the images in real time, providing a cost-effective alternative to whole slide imaging.
Dimension + Multiposition
Standard + Multiposition
With cellSens Dimension, and a motorized stage, large-area image acquisition is fully automated with the optional Multiposition solution. When combined with a motorized Z or focus maintenance device, like our TruFocus™ technology, this function can correct for the effects of sample distortion and tilting.
EFI
Dimension
Standard + Manual Process
Create a single in-focus image from successive image planes as you turn the focus knob using the Extended Focus Imaging (EFI) function. A motorized focus drive fully automates EFI acquisition. EFI composite images can also be created directly from previously captured Z-stacks.
HDR Acquisition
Dimension
By automatically capturing many images at different exposures, the HDR function creates a final image with a higher dynamic range than could be achieved on a single exposure. Low-intensity signals are clearly visible without overexposing the bright areas of the sample.
Image Processing and Sharing
Reveal the true data in your images with TruSight deconvolution and other image processing techniques. Easily share your results with others using Conference Mode or drag and drop data into preconfigured reports.
Powerful TruSight™ Deconvolution
Dimension
cellSens Dimension includes live 2D deblurring for image preview and acquisition to enable better focusing on thick specimens.
Dimension + CI Deconvolution
The Constrained Iterative Deconvolution solution has the latest algorithms for improved resolution, contrast, and dynamic range with industry-leading speed through GPU processing. Algorithms designed specifically for use with FLUOVIEW™ and Evident Super Resolution (OSR) images provide clearer, sharper images from high-end systems utilizing ultrafast frame rates and high sensitivities.
Cell line: Human cervical cancer cell line (HeLa)*1
Immunostaining: Hec1 staining (green, Alexa Fluor-488), a-tubulin staining (red, Alexa Fluor-568), DAPI staining (blue)
Mitotic HeLa cell derived from human cervical cancer. Mitotic spindle and kinetochores are stained with anti-a-tubulin (red) and anti-Hec1 (green) antibodies, respectively. Chromosomes interact with microtubules constituting mitotic spindle via kinetochores, protein structure assembled on centromere region of chromosomes.
Image data courtesy of: Department of Molecular Oncology, Institute of Development, Aging, and Cancer, Tohoku University Masanori, Ikeda and Kozo Tanaka
*To learn more about the origin of HeLa cells, visit henriettalacksfoundation.org.
Focus on What's Important
Dimension
Objectively determine the best focus from multidimensional images, including Z-stack and time-lapses, using the Best Focus Extraction tool. This tool is effective in creating T-series images with the best focus possible.
Visualize three-dimensional data in a single plane using maximum intensity projections, which combine Z-series planes into a single image with the brightest pixels all in view.
Real-Time Collaboration
Dimension
Standard
Use Conference Mode to fill the screen with live or static images for presentation and collaboration. Graphic annotation tools are available at your fingertips for image markup without the need to exit Conference Mode, improving workflow efficiency and saving time.
Dimension + NetCam
Standard + NetCam
Using standard TCP/IP protocols, the cellSens NetCam Solution facilitates the transfer of live and stored images throughout a network for teaching, mentoring, or supervision. Even when outside of the laboratory, colleagues or supervisors can monitor the work from any point on the network, improving the efficiency of the laboratory.
A Different Perspective
Dimension
Standard
Display images side-by-side for accurate comparison with simultaneous zooming and movement for faster image processing.
Dimension
Tile View mode enables you to view multidimensional datasets all at once, making fine movements or events easier to identify.
Simple Data Reporting
Dimension
A convenient Reporting tool combines images and measurement metadata into a report template with easy drag-and-drop operation. These Microsoft Word*2 reports enable you to quickly and easily collaborate with colleagues and communicate results.
*2 Requires Microsoft Word version 2010 or later
Spectral Unmixing
Dimension
With the linear unmixing algorithm in cellSens Dimension, fluorochromes that overlap in their emission spectra—such as GFP and YFP—can be readily separated to produce crosstalk-free fluorescence images. This linear unmixing tool can also separate autofluorescence-related background signals.
Powerful Analysis Tools
Dynamically work with your images to extract the most data for reliable experimental results. The software’s TruAI deep-learning technology offers improved segmentation analysis. Use the Macro Manager to automate entire workflows all the way through image analysis and saving.
Green: You can see that the detection accuracy is low due to unevenness of the GFP label.
Blue: Detecting the nuclei with high accuracy despite scratches and dust on vessel.
TruAI Deep Learning
Dimension + Deep Learning
Standard + Deep Learning
Experience the benefits of cellSens software’s TruAI deep-learning technology to improve your image analysis. From automatic segmentation of complex morphologies without hand labeling to segmentation of cells or organelles using a simple transmitted light image, deep-learning technology offers improved speed and efficiency without the phototoxicity of fluorescence.
Object Count and Measure
Dimension
Standard + Count and Measure
Efficient and precise threshold-based object detection for automated nuclei counting and classification are available. Conveniently export your results to Microsoft Excel for additional analysis.
Dimension + Count and Measure
Standard + Count and Measure
Expand on the extensive manual measurements already available in cellSens software with the Count & Measure module. Easily perform automatic object measurement and classification in an interactive interface where recognized objects are always linked with their measurements.
Dimension + Count and Measure + Deep Learning
Standard + Count and Measure + Deep Learning
Improve your count and measurement by detecting objects with deep learning.
Live-Cell Solutions
Dimension
Standard + Confluency Checker
Our specialized cell identification algorithm enables you to measure cell count and confluency on phase contrast images, including data averaging and total cell count estimation. A cell growth curve can be output by measuring along with time series.
Dimension + Count and Measure + Tracking
cellSens software's Object Tracking solution provides a powerful and intuitive tool to quantify dynamic processes such as cell movement and division. Moving objects can be automatically detected, tracked, and analyzed over time.
Intensity Measurement
Dimension
Graphically depict intensity and ratio values defined by regions of interest (ROIs) and adjust ROI placement to compensate for cell movement. Convert intensity variations to hue and brightness using intensity modulated display (IMD) to visually enhance the fine structures often found within ratio or FRET images.
Dimension + Ratio/ FRET or Life Science Analysis
The Ratio/FRET solution is used to display and analyze real-time ratiometric imaging data. FRET analysis of both sensitized emission and acceptor photobleaching is supported in this user-friendly workflow.
Dimension + Life Science Analysis
The Photo-Manipulation Solution can be used for curve-fitting analysis of FRAP images.
Simple Macro Experiments
Dimension
Save time and clicks by using the macro manager to automate typical acquisition and data analysis workflows. Batch Macro commands can be applied to multiple images simultaneously and can reduce the time required to complete complex image acquisition and analysis.
Customizable User Interface
Choose a recommended layout for image acquisition and analysis or create your own using the My Functions tool set.
Intuitive at All Skill Levels
Dimension
Standard
Novice and expert users will simultaneously benefit from the Simple Layout, an interface designed for a clinical research workflow.
- Acquire, annotate, share, and save your images using the intuitive Smooth Control tool window.
- Built-in measurement tools display only when required, reducing software clutter and minimizing distraction.
More complicated experiments benefit from premade layouts where all common functions are integrated into tabs, combining related options and settings. Layout tabs make it easy to select functions according to the workflow. For example, camera control features are displayed under the Acquisition tab, but are hidden when you switch to the Processing tab in the next stage.
Build Your Own Layout
Dimension
Standard
Tools and windows can be organized to suit the job at hand, optimizing the layout’s functionality. This enables you to spend less time training and more time imaging.
You can create and save custom toolbars for frequently used functions and save them to the My Functions window, where they can be used to improve efficiency when working with your most commonly used tools.
Minimize Monitor Glow
Dimension
Standard
The Dark Application Skin reduces computer monitor-generated ambient light, helping you adapt to darkened environments, like those required when imaging samples with fluorescence. Icon contrast remains high for easy recognition and quick selection.
Specifications
cellSens Solutions Software Modules |
y = included O = optional |
Entry | Standard | Dimension |
| Manual Process | Easily create high-resolution composite images (Instant MIA) by simply moving the manual stage. You can also acquire a focused image (EFI) over the entire surface by manually shifting the Z direction. | o | o | y |
| Encoded Device | Encoded devices (objectives, light intensity, etc.) make it easy to recall settings. | o | y | y |
| Interactive Measurement | Draw a polyline, rectangle, or circle on top of your image to obtain exportable measurement data. Measurement results can be exported to Excel. | o | y | y |
| Database Client | Access to the database created with the Database Core option. | o | o | o |
| Database Core | Make data management and browsing more efficient by creating a database that can easily search and sort acquired images based on data, such as imaging conditions and acquisition date. | o | o | |
| Confluency Checker | Determine the confluency of unstained live cells in culture dishes through quantitative measurements for reliable data. | o | y | |
| Multiposition | Multipoint and stitched images can be acquired using the motorized stage. When combined with the motorized Z, a focus map can be created from multiple points of focus, and you can obtain stitched images with little focus deviation by removing sample tilt and distortion. | o | o | |
| Count & Measure | Define the morphology of an object, and the software will identify all similar objects and present segmentation analysis results in a chart. | o | o | |
| NetCam | Facilitates the transfer of live and stored images through a network for teaching, mentoring, or supervision. | o | o | |
| Deep Learning |
Efficient segmentation analysis powered by deep learning enables challenging target detection, such as label-free nucleus detection. Image enhancement possibilities including self-supervised denoising (noise to void). |
o | o | |
| Well Plate Navigator*1 | Easily set the capture settings for each well. The well position and name can be tagged to images, making data management easier and well plate screening more efficient. | o | ||
| CI Deconvolution | Access to GPU-based deconvolution as well as popular and custom TruSight deconvolution algorithms to improve the sharpness, contrast, and dynamic range of reconstructed images. | o | ||
| Ratio/FRET | Obtain ratio measurements from your images as they’re being acquired. | o | ||
| Tracking*2 | Measure and analyze the luminance and speed of individual cells that move and divide over time. | o | ||
| Life Science Analysis | FRAP/FRET analysis can be performed on the acquired image. | o | ||
| Photo Manipulation | Enables cell frap module control and FRAP analysis. | o | ||
| Laser Control | Enables NI USB-6343 BNC to control external devices. | o | ||
| Automated Correction Collar (ACC) | Operating automated correction collar. | o | o | |
| Super Resolution for cellSens*3 | Renewed super resolution (online and offline) | o |
cellSens Functions |
✓ = included - = not included |
Dimension | Standard | Entry |
| Layout | User experience customization | ✓ | ✓ | ✓ |
| View | Overlay multiple images | ✓ | ✓ | - |
| Document groups for side-by-side image comparison | ✓ | ✓ | ✓ | |
| Movie playback | ✓ | ✓ | ✓ | |
| Tile view (multiple images in a single data set shown side-by-side) | ✓ | ✓ | ✓ | |
| Slice view for orthogonal plane viewing of 3D or time-lapse data sets | ✓ | - | - | |
| Voxel viewer for isosurface and volumetric rendering of 3D and 4D data sets | ✓ | - | - | |
| Image Acquisition | Snap/movie acquisition | ✓ | ✓ | ✓ |
| Time-lapse at specified interval | ✓ | ✓ | - | |
| Automated multiwavelength | ✓ | ✓ | - | |
| Z-stack | ✓ | - | - | |
| Multidimensional (XYZT and wavelength) | ✓ | - | - | |
| Graphical Experiment Manager | ✓ | - | - | |
| Manual panoramic imaging (Instant MIA and Manual MIA) | ✓ | Manual Process | Manual Process | |
| Multiposition visitation and stage navigator | Multiposition | Multiposition | - | |
| Automated panoramic imaging (auto MIA, requires motorized stage) | Multiposition | Multiposition | - | |
| Instantly create EFI image (manual or motorized Z) | ✓ | Manual Process | Manual Process | |
| Simultaneous multicolor Imaging (requires two identical cameras** or image splitter) | ✓ | - | - | |
| Live deblurring | ✓ | - | - | |
| High dynamic range imaging (HDRI) | ✓ | - | - | |
| Multiwell plate acquisition | Well plate navigator and Multiposition | - | - | |
| Automated correction collar (ACC) | ACC | ACC | - | |
| Super-resolution filter with renewed algorithm | ✓ | - | - | |
| Image Processing | Geometry/combine/filter processing | ✓ | ✓ | - |
| Fluorescence unmixing | ✓ | - | - | |
| Brightfield unmixing | Count & Measure | - | - | |
| Deblurring (No/Nearest Neighbor, Wiener Filter) | ✓ | - | - | |
| Kymograph | ✓ | - | - | |
| 2D deconvolution | ✓ | - | - | |
| 3D deconvolution (constrained iterative deconvolution with GPU process) | CI Deconvolution | - | - | |
|
Deep Learning (TruAI) |
Training of neural networks | Deep Learning | Deep Learning | - |
| Inference using trained neural networks (offline/online) | Deep Learning or Count & Measure | Deep Learning or Count & Measure | - | |
| Image Analysis | Phase analysis | ✓ | - | - |
| Object measurements and classification | Count & Measure | Count & Measure | - | |
| Interactive 2D measurements | ✓ | ✓ | ✓* | |
| Intensity plot over time/z | ✓ | - | - | |
| Colocalization | ✓ | - | - | |
| Object counting (manual) | ✓ | ✓ | - | |
| Object tracking | Tracking and Count & Measure | - | - | |
| Online ratio and kinetics | Ratio/FRET | - | - | |
| Ratio analysis (offline) | ✓ | - | - | |
| FRET analysis | Ratio/FRET or Life Science Analysis | - | - | |
| FRAP analysis | Photo Manipulation or Life Science Analysis | - | - | |
| Cell count and confluency measurements | ✓ | Confluency Checker | - | |
| Documentation and Collaboration | Automatically compose MS Word reports | ✓ | - | - |
| Database image and data management solution for microscopy | Database Core | Database Core | - | |
| Open database and load records/documents from database | Database Client | Database Client | Database Client | |
| Remoting | Remote live image viewing | NetCam | NetCam | - |
* Three-point angle, four-point angle, arbitrary line, closed polygon, polyline, and perpendicular line only. Interactive measurement option is needed to add other measurement tools and make exporting Excel spreadsheets possible.
**Supported cameras: iXon Ultra 897, Zyla 5.5 (USB 3.0), Zyla 4.2 (USB 3.0/CamLink), Neo, iXon Ultra 888, ImagEM X2, ORCA-Flash 4.0 (V3), Prime 95B, Prime BSI, Prime BSI Express, Sona4.2B-11, Kinetix, Kinetix 22, ORCA-Fusion, ORCA-Fusion BT, ORCA-QUEST.
Products with Confirmed Functionality |
✓ = included - = not included | Dimension | Standard | Entry | |
| Evident | Camera | DP22, DP23, DP23M, DP27, DP28, DP74, DP75, DP80, XM10, UC90, LC20, LC30, LC35, SC50, SC180 | ✓ | ✓ | ✓ |
| Microscope |
BX43, BX53, BX63, BX61, BX61WI, IX83, IX85, IX73, IX81, SZX16A |
✓ | ✓ | - | |
| IX81-ZDC, IX81-ZDC2 | ✓ | - | - | ||
| Peripherals | BX-DSU, IX3-DSU, IX3-ZDC, IX3-ZDC2, IX2-DSU, IX2-ZDC, IX2ZDC2, U-CBF, cellTIRF (multiline, single line), USB-ODB converter, Real Time Controller (U-RTCE, U-XRTC) | ✓ | - | - | |
| Light Source | U-LGPS, U-FFLED | ✓ | ✓ | - | |
| Hamamatsu | Camera | ImagEMX2*, ORCA-Flash 4.0 V3, ORCA-Flash 4.0 LT PLUS, ORCA-Flash 4.0 LT3, ORCA-Fusion, ORCA-Fusion BT, ORCA-QUEST, ORCA-Halo | ✓ | - | - |
| ORCA-spark* | ✓ | ✓ | - | ||
| Image Splitter | W-View Gemini | ✓ | - | - | |
| Q-Imaging | Camera | Retiga 6000 | ✓ | - | - |
| Photometrics | Camera | Prime (PCI-Express), Prime 95B, Prime BSI, Prime BSI Express, Moment, Kinetix, Kinetix22 | ✓ | - | - |
| Image Splitter | Dual View DV2 / QuadView QV2 | ✓ | - | - | |
| Andor | Camera | iXon Ultra 897, iXon Ultra 888, iXon Life 888, iXon Life 897, Sona4.2B-11,Zyla4.2/Zyla4.2 PLUS (Camera-link,USB3.0), Zyla5.5 (Camera-link 10tap,USB3.0), ZL41 Cell 4.2 (Camera-link,USB3.0), Neo5.5 | ✓ | - | - |
| Vincent Associates | Shutter | Uniblitz shutter (VCM-D1, VMM-D1, VMM-D3) | ✓ | ✓ | - |
| CoolLED | Light Source | pE-1, pE-2, pE800, pE-4000, pE-400 max | ✓ | - | - |
| pE-300white, pE-300ultra, pE-340fura | ✓ | ✓ | - | ||
| Excelitas | Light Source | X-Cite120LED, X-Cite XYLIS, X-Cite TURBO, X-Cite NOVEM | ✓ | - | - |
| Lumencor | Light Source | SOLA SEII, SEII 365, Spectra X | ✓ | - | - |
| Sutter | Shutter, FW | Lambda 10-3/10-B | ✓ | ||
| Prior | Motorized XY Stage | ProScan III, Optiscan III | Multiposition | - | - |
| Shutter, FW, Z-drive | ProScan (I, II, III) , Optiscan III | ✓ | - | - | |
| Piezo Z (Control via Real Time Controller) | NanoScanZ NZ100 | ✓ | - | - | |
| Ludl | Motorized XY Stage | Mac 6000 | Multiposition | - | - |
| Shutter, FW, Z-drive | Mac 6000 | ✓ | - | - | |
| Märzhäuser | Motorized XY Stage | Tango, Pilot Stage | Multiposition | - | - |
| Z-drive Controller | Tango | ✓ | - | - | |
| Physik Instrumente | Piezo Z (Control via Real Time Controller) | PIFOC P-721 | ✓ | - | - |
| Applied Scientific Instrumetation | Motorized XY Stage | MS-2000 | Multiposition | - | - |
| Z-drive Controller | MS-2000 | ✓ | - | - | |
| National Instruments | Digital TTL Device | NI USB-6501 | ✓ | - | - |
| NI USB-6343 BNC | Laser Control | - | - | ||
| Yokogawa | CSU | CSU-X1, CSU-W1 | ✓ | - | - |
| Magnification Changer | IX SPIN-SR | ✓ | - | - | |
| CrestOptics | CSU | X-Light V3 | ✓ | - | - |
For details on Windows OS compatibility, please contact your Evident sales representative.
*Not in combination with other Hamamatsu cameras
Compatible image formats
System Requirements
Up to 7 GB for installation
Recommended for high-speed image acquisition: solid state drive (SSD)
Software Version Update
A version update is available for the next version following the version written on the license card (excludes updating sub-minor versions). An update that spans two or more major or minor versions requires an update license, which provides access to the latest version of cellSens software after the above period.
Check the latest version for your software: License Information
Downloads
Release Notes
Version 4.5
New Hardware Support
- U-FLLED: Fluorescence LED light source
- U-XRTC: New real-time controller
New Functions and Improvements
- NVIDIA Blackwell chipset GPU is supported for CI deconvolution and deep learning
- AI denoising (N2V) for fluorescence
- Renewed online help
- Interface to send image data to ImageJ/Fiji for limited macro operations
Version 4.4.1
New Hardware Support
- Hamamatsu ORCA-Halo (C17440-2OU)
- CoolLED pE-400 max
- Excelitas X-Cite NOVEM
New Functions and Improvements
- Improved support of spinning disk;
automated correction collar with spinning disk imaging,
new Wiener filter and CI deconvolution support,
support of combined magnification lenses - Photobleaching Prevention mode can be used with sensitive samples
- Macro to Micro workflow with improved support of focus map
- Prior driver update: better support of workflow with silicone gel objective lens
- Image export to scanR
Version 4.4
New Hardware Support
- Yokogawa Magnification Changer
- Crest X-Light V3
- Teledyne Kinetix and Kinetix22
New Functions and Improvements
- Renewed super resolution algorithm allows calculation under manifold conditions and results in a superior image quality
- Super resolution preview functionality is possible with channel-dependent settings
- New spinning disk control window allows easy overview and modification of device settings
- Enable to optimize the subframe size based on the field number (FN)
Version 4.3.1
New Hardware Support
- IXplore™ IX85 microscope system
- Motorized correction collar (ACC)
- New gel lens objectives
- Hamamatsu Photonics ORCA-Quest 2 (C15550-22UP)
New Functions and Improvements
- Distortion correction and camera shift correction improve the image quality
- Motorized correction collar enables automatic adjustment
- Easy handling of sample settings is integrated into cellSens software
- Improved stitching functionality, including Instant Multiple Image Alignment (MIA)
- Intelligent shading correction support can remove shading without calibration
Version 4.3
New function/improvement
- National Instruments USB-6343 BNC device support
- Piezo Z devices, shutters, lightsources and IX3-FRAP are added
- Hamamatsu Photonics Quest camera
- Photon Number Resolving mode has been added
- Stability and auto exposure performance has been improved
- DP75 with 4K resolution
- It is able to use 3840x2160 (4K) for live snapshot and movie with up to 30.0 fps
- EFI resolution limit
- The limit of EFI (Extended Focus Image) has been increased to ~12MP (4096x3000 pixels)
- Deep Learning Inference
- Support ONNX Runtime with DirectML for inference, and processing speed has been improved for CPU or Non-NVIDIA GPU condition.
Version 4.2.1
New hardware support
- Evident DP75
- Hamamatsu Photonics ORCA Quest
- Andor ZL41 Cell 4.2
- National Instruments USB-6343 BNC
New function/improvement
- TruAI(Deep Learning)
- Categorize drop down menu of neural network selection
- Added scaling possibilities for neural network application
Neural network information and "Manage Neural Network" dialog has been improve.
Version 4.2
New hardware support
- Hamamatsu ORCA Flash4.0 LT3
New function/improvement
- Magnification calibration
- Calibration slide enables partly automatic magnification calibration.
- Calibration report can be exported.
- Experiment Manager
- Observation Method, Exposure time and Camera settings can be set during the Overview Acquisition setting, making experiment more efficient.
- The sample detection setting in the Stage Navigator can be easily reflected in other experiments.
- 2D/3D deconvolution processing is available during the experiment.
- TruAI(Deep Learning)
- Image Regression function enable the creation of good signal-to-noise ratio images.
- Interactive training function makes training more efficient.
- Improved traceability of experimental protocols by being able to identify the network information used
- Add a neural network for segmentation “IHC Nuclei Classification”.
- Scale bar transparency
- Rotate view Improvement in live mode.
- Export of multi-channel images is improved to allow simultaneous export of each channel and merged image.
- Add a new method for offline MIA.
- Simplified access to the FLUOVIEW software.
Object Counting is available in cellSens Entry.
Version 4.1.1
New hardware support
- Type 2 models for DP23, DP23M, and DP28 are now supported.
- Note: You can find the hardware revision number of the DP23 and DP28 cameras
- (Rev. 1 or Type 2) on the camera's type plate.
Minor bug improvements
- Adjusting of MIA images border from the Process Manager.
- Load settings for Well Navigator
- Correlation values in Colocalization
- Stability of Shading correction calibration
Version 4.1
New hardware support
- Teledyne Photometrics:Prim BSI Express(High sensitivity sCOMS)
- CoolLED:pE800(8-channel LED light source)
New function/improvement
- “Automatic Sample Detection” in the Stage navigator.
- “Generic” and “AI” algorithms are available for setting the multi-imaging areas.
- “Overview Acquisition” in the Experiment manager
- At the beginning of the experiment, the overview image can now be captured, and sample detection can be performed automatically using “Automatic Sample Detection” function.
- Macro to Micro imaging is available.
- Improvement of TruAI (Deep learning function)/
- Added the new Instance segmentation. “Individual Objects” check box in the training label class. Overlapping objects can be separated individually.
- Pre-trained neural network for detecting the Nuclei and the Cells in the cellSens Count and measure full option and Deep learning option.
- Additional GPUs of NAIDIA RTX3080, RTX A4000 are supported.
- Improvement of shading correction
- “Special” algorithm is available.
- “Smoothing filter” can be used in the standard calibration.
- Improvement of Deconvolution
- “2D no neighbor” algorithm can be used in the Online deblur.
- Additional GPUs of NAIDIA RTX3060i, RTX3070, RTX3080, RTX A4000 are supported.
- Log files related to deconvolution are included in the “Customer Support Information”.
- Save pixel calibration in JPEG image
- Save and open pixel calibration with the JPEG image.
- Length and area measurement in JPEG images.
- Creating the training labels are available with all cellSens packages.
- New splash display with uniformity with other software.
- The new update policy.
- The update licenses renamed to OUT (One Time Update).
Version 3.2
New hardware support
- Evident: U-LGPS LED and LDP light source
- Teledyne Photometrics: Moment Global shutter scientific CMOS camera
New function/improvement
- Improvement of TruAI (deep learning function)
- The minimum image size for training files is 512x512.
- In addition to VSI images, TIFF images can be used for training.
- The number of image files used for training is displaied in the training setting
- “Basic mode" and “Expert mode" for more detailed settings are selectable for the training.
- Additional neural network types are available for the training.
- Several types of training duration setting are available.
- Check point can be set at any timing in the training setting.
- Live display of inference results is possible and the results can be confirmed before the image acquisition.
- Deep Learning inference and object counts can be run at once
- Magic Wand is available for making annotations on the training images.
- In case of Z-stack images processed, inference results are displayed for each frame.
- Neural network processing information is showed on the properties of the processed images.
- Additional GPUs of NVIDIA RTX3060Ti and RTX3070 are supported.
- Restore function of cellSens condition to specified restore point is available (public information only).
- The data recovery process can be enabled or disabled. In case of "disable", total time for the data acquisition can be reduced without the data recovery processing and this is beneficial especially for large volume data acquisition.
- The period for the log collection can be specified.
- Execution of the macro can be set in the Graphical Experiment Manager. The macro is executed just after the acquisitionon completed (specific processings only).
- Additional ways of image export are available.
- Raw data and Merged channels: The image of each channel and the merged image are exported.
- Raw data and Merged channels with Burn in Info: The image of each channel and the merged image are exported, information is burned.
- Improvement of NetCam function environment compatibility
- Improvement of image cropping function
- Acquired images can be cropped by specifying the XY position and size numerically.
- ROI part can be saved as a new image.
- CoolLED pE-300 white and pE-300 ultra LED light sources are supported in cellSens Standard
Version 2.3
New hardware support
- Hamamatsu: ORCA-Fusion Scientific CMOS camera
- CoolLED: pE-300white, pE-300ultra, pE-340fula LED light source
- Andor: Sona 4.2B-11 Scientific CMOS camera
New function/improvement
- Support of Hamamatsu ORCA-spark CMOS camera by cellSens Standard
- Improvement of automated MIA
- Acquisition of multi-color overview image
- Define MIA area by polygon
- Background color selection
- Manual selection of Extract Best Focus (Custom Selection mode)
- Improvement of Line Profile
- Polyline and Free hand
- Multiple line in one image
- Zoom function in Tile View mode
- Improvement of calculation algorithm of 3D deconvolution
Version 2.1
New hardware support
- Hamamatsu ORCA FLASH LT PLUS
Product portfolio changes
- High-end Camera is eliminated and integrated into Dimension
- High-end Device is eliminated and integrated into Dimension
- Multi-Color Acquisition is eliminated and integrated into Standard
- Three New Solutions for Entry
- Manual Process: Enable manual MIA and manual EFI
- Encoded: Enable control of encoded devices
- Interactive Measurement: Enable exporting measurement result to Excel
New function/improvement
- GPU processing for CI deconvolution
- Support of Position Group properties for automatic naming/saving
- Improvements to Export Image dialog including; Marge Channel, Burn in Info and Split Channels
- Save as OIR format
- Import OME tiff format image
- Batch conversion
- Adjust print resolution (PPI) of images
- Execute macro for Shading correction in FV3000
- Select All detected objects in Count and Measure
- EFI command in Experiment manager
- Hide alert when manual device is changed
Resources
Insights
Product Resources
Videos
Meet cellSens™ Imaging Software
cellSens Software’s Context Help Function
cellSens™ Tutorial: Naming and Saving Tools
cellSens™ Tutorial: Real-Time Ratio Analysis
cellSens™ Tutorial: Ratio Analysis
cellSens™ Tutorial: Customizing the User Interface and Layouts
Simple Layout in cellSens Software
cellSens™ Tutorial: System Restore
scanR High-Content Screening System with Deep Learning: Monitoring Cell Cycle Dynamics During Stem Cell Differentiation
cellSens: Deep Learning Part3. Manually Label Images to Prepare the Deep Learning Training Data
DP74 Multiframe Live Noise Reduction (FNR)
cellSens: Well Plate Navigator Part3. Grouping Wells and Assigning Individual Observation Conditions
cellSens: Well Plate Navigator Part2. Acquiring Multichannel Z-Stack Images
cellSens: Well Plate Navigator Part1. Preparation
cellSens:Deep Learning Part2. Using the Training Data to Identify Nuclei
cellSens: Stage Navigator Polygon
cellSens:Multiple Image Alignment with Stage Navigator
cellSens: Real-Time Panoramic Imaging
cellSens: Simple Layout
cellSens: Real-time Panoramic Imaging Function
cellSens: Personalized Userinterface Function
cellSens: Object Detection Function
cellSens: Multidimensional Imaging Function
cellSens: Layout Intelligence Function
cellSens: Interactive Measurement Function
cellSens: 3D Deconvolution Function