Perform Accurate and Efficient Microscopy Image Analysis Using TruAI based on Deep Learning

Introduction

Experiments often require data from microscope images. For accurate image analysis, segmentation is important to extract the analysis target area from the image. A common segmentation method is to apply thresholds to the image intensity values or color.

While effective, this method can be time-consuming and affect the sample condition. Next-generation image analysis methods like our cellSens imaging software with deep-learning-based TruAI help reduce the risks of sample damage while achieving high efficiency and accuracy.

Application Examples Using TruAI

1) Label-Free Nucleus Detection and Segmentation

To count the number of cells, localize nuclei in cells and tissues, and evaluate the cell area, researchers commonly use fluorescent staining of nuclei to segment based on the fluorescence intensity information.

In contrast, TruAI can perform nucleus segmentation using only brightfield images. It works by training a neural network using the nucleus segmentation results from brightfield and fluorescence images.

This self-learning microscopy approach eliminates the need to fluorescently stain the nucleus once the neural network is created. Other benefits include:

Figure 1

Figure 2: Compared to the fluorescence image (left), Olympus’ TruAI clearly distinguishes close nuclei from one another (right), indicating that detection is possible with high accuracy.

Figure 2

Figure 1: While the brightfield image (left) has minimal contrast due to unstained cells, the TruAI detects the nuclei with high accuracy (right).
Figure 2: Compared to the fluorescence image (left), Olympus’ TruAI clearly distinguishes close nuclei from one another (right), indicating that detection is possible with high accuracy.

Read the white paper

2) Quantitative Analysis of Fluorescently Labeled Cells with Ultra-Low Light Exposure

Fluorescent labels are an invaluable tool in modern microscopy-based cell studies. However, the high exposure to excitation light can lead to photodamage or phototoxicity and have an observable impact on cell viability. Even if no direct effect is observed, strong light exposure can influence the cells’ natural behavior, leading to undesired effects.

In long-term live cell experiments, minimal light exposure during fluorescence observation is ideal. From a technical standpoint, ultra-low light exposure means analyzing images with very low signal levels and, consequently, low signal-to-noise ratios. Our TruAI enables you to analyze low-signal images with both robustness and precision.

Figure 3: The result of detecting nuclei (right) from a fluorescence image (left) with sufficient luminance using a conventional method that applies a luminance threshold. Figure 3
Figure 4: The result of detecting nuclei (right) with the same conventional method as Figure 3, from fluorescence images (left) with extremely poor SNR due to weak excitation light. You can see that the detection accuracy is low. Figure 4
Figure 5: The result of detecting nuclei (right) using TruAI from a fluorescence image (left) with extremely poor SNR due to weak excitation light. You can see that the accuracy is as high as Figure 3 and performed with much higher accuracy than Figure 4. Figure 5

Figure 3: The result of detecting nuclei (right) from a fluorescence image (left) with sufficient luminance using a conventional method that applies a luminance threshold.
Figure 4: The result of detecting nuclei (right) with the same conventional method as Figure 3, from fluorescence images (left) with extremely poor SNR due to weak excitation light. You can see that the detection accuracy is low.
Figure 5: The result of detecting nuclei (right) using TruAI from a fluorescence image (left) with extremely poor SNR due to weak excitation light. You can see that the accuracy is as high as Figure 3 and performed with much higher accuracy than Figure 4.

Read the white paper

3) Segmentation Based on Morphological Features

If you want to segment an image based on its morphological features, it is very difficult to achieve high-precision segmentation with the conventional approach of applying thresholds to intensity values and color. Therefore, it was necessary to manually count and measure each time.

In contrast, TruAI enables highly efficient and accurate segmentation based on morphological features. After the neural network learns the segmentation results from hand-labeled images, it can apply the same methodology to additional data sets. For instance, neural networks trained from hand-labeled images can count mitotic cells, as depicted in the images below.

Figure 6: Prediction of mitotic cells using TruAI (green). Figure 6
Inserting image... Figure 7

Figure 6: Prediction of mitotic cells using TruAI (green).
Figure 7: While you can see many cells, only the dividing cells are detected (right).

4) Tissue Specimen Segmentation

TruAI can also be used to segment tissue specimens. For example, kidney glomeruli are difficult to discriminate using conventional methods but can be segmented using TruAI.

Figure 8: Prediction of glomeruli positions on a mouse kidney section using TruAI (blue). Figure 8
Figure 9

Figure 8: Prediction of glomeruli positions on a mouse kidney section using TruAI (blue).
Figure 9: TruAI captures and detects the glomeruli features (right).

Conclusion

Conventional segmentation methods can be difficult and cause damage to samples. Our cellSens imaging software with deep learning enables accurate and efficient segmentation in conditions that cause minimal damage to cells, such as label-free imaging or ultra-low light exposure. The software also makes it easier to perform segmentation of tissue specimens based on their morphological features.

FV5000

Confocal Laser Scanning Microscope

  • Extraordinary clarity, speed, and reliability driven by groundbreaking innovations
  • SilVIR™ detectors deliver photon-level quantitation, exceptional sensitivity, and ultra-high signal-to-noise
  • Unmatched dynamic range captures the full signal spectrum and prevents saturation
  • High-speed 2K resonant scanning and high-density 8K galvo scanning in one platform
  • FLUOVIEW Smart™ software simplifies operation with intuitive controls and AI-powered automation
  • TruResolution™ auto correction collar optimizes focus for over 20 objectives
  • Modular design supports up to 10 laser lines and future multiphoton upgrades
  • Laser Power Monitor (LPM) ensures stable illumination and reproducible results over time

Learn More

FV5000MPE

Multiphoton Laser Scanning Microscope

  • Compact fiber-pigtailed lasers enable deep, quantitative imaging in scattering tissue
  • One-, two-, or three-line simultaneous MPE laser excitation for millimeters deep imaging
  • SilVIR™, TruAI, and TruSight™ technologies deliver outstanding signal-to-noise and clarity
  • MPE-optimized objectives, TruResolution™ auto correction collar, and automated IR laser alignment maintain sharp focus
  • Available as an FV5000 system upgrade or a complete MPE system
  • Fully tunable laser configurations available for more advanced multiphoton applications

Learn More

IXplore Live

Live Cell Imaging Microscope System

Designed to reduce photobleaching and phototoxicity, the IXplore Live system is optimized for physiological experiments involving live cell and tissue observation. Offering precise environmental control and enhanced rigidity, it supports long-term cell viability and stability for time-lapse imaging applications, such as in cancer, stem cell, and brain research.

  • Maintain focus accurately and reliably in time-lapse experiments with TruFocus™ Z-drift compensation system
  • Discover the real morphology of your cells with Olympus silicone immersion optics
  • Real-time controller helps limit cell disturbance, enabling physiologically relevant data

Learn More

BX63

Automated Fluorescence Microscope

  • Fully motorized system allows automation of complex multidimensional experiments
  • Accurate motorized Z-drive
  • High stability due to fixed stage design

Learn More

View larger image: cellSens Microscope Imaging Software Image 1 of 1

cellSens

Imaging Software

Providing intuitive operations and a seamless workflow, cellSens software’s user interface is customizable so you control the layout. Offered in a range of packages, cellSens software provides a variety of features optimized for your specific imaging needs. Its Graphic Experiment Manager and Well Navigator features facilitate 5D image acquisition. Achieve improved resolution through TruSight™ deconvolution and share your images using Conference Mode.

  • Improve experiment efficiency with TruAI™ deep-learning segmentation analysis, providing label-free nuclei detection and cell counting
  • Modular imaging software platform
  • Intuitive application-driven user interface
  • Broad feature set, ranging from simple snapshot to advanced multidimensional real-time experiments

Learn More