Extended Time-Lapse Imaging of Cell Motility and Proliferation Using the Olympus FLUOVIEW FV3000 and TruFocus Z-Drift Compensation System

Cell culture-based imaging assays are foundational pillars for investigating a variety of biological phenomena. Using this technique, researchers can observe cellular proliferation and dynamics over time. Because cell populations can exhibit locally diverse protein expression profiles and patterns of motility, imaging assays need to be carefully designed to avoid biases and skewed results created by insufficient sampling. Thus, cell culture-based imaging experiments should be designed to accommodate multiple fields of view across the microplate well or culture device. This application note explores how the FV3000 microscope can facilitate capturing multi-area time-lapse images with complex acquisition parameters for thorough and robust datasets from a single experiment.

Capturing Multiple Fields of View in a Single Experiment

In this experiment, the FV3000 confocal microscope’s multi-area time-lapse (MATL) module was used to continuously monitor the motility and proliferation of human umbilical vein endothelial cell (HUVEC) populations expressing cytosolic green fluorescent protein (GFP) during a span of ~12.5 hours. While designing the experiment, it was important to monitor multiple regions with various magnifications and Z-stack parameters to track individual cell dynamics as well as the dynamics of the population as a whole. Because the MATL module permits independent XYZT parameters to be registered for each position or tiled area, it was easy to program various imaging conditions for multiple regions with differing magnifications and Z-stack parameters over time.

Independent XYZT parameters are saved for each position in the multi-area time-lapse software so different imaging conditions are programmed for specific regions with differing magnifications and Z-stack parameters over time.

Figure 1. Multi-area time-lapse experiment schematic. For each well in the well plate, multiple positions of individual and tiled areas were programmed with various independent magnification and Z-stack parameters. These registered positions were imaged in a cycle over the course of 12 hours and 25 minutes.

Using Location-Specific Autofocus to Track HUVEC Cell Motility and Proliferation

One of the biggest challenges in imaging multiple areas over time is the tendency for focus to gradually shift because of small fluctuations in the temperature of the microscope room environment. Additionally, the distance between the coverslip surface and the sample tissue can vary over its surface area, making it even more challenging to obtain clear images over multiple fields of view. The TruFocus Z-drift compensation system combats these problems by utilizing a nonphototoxic near-infrared laser to locate the coverslip-sample interface and determine the corresponding focal position. By combining the TruFocus system with the MATL feature, it is simple to register multiple independent XYZT positions with location-specific autofocus.

In this experiment, multiple regions with differing magnifications and Z-stack parameters were cycled over time to track changes in motility and proliferation of the HUVECs, both at the individual cell level as well as at a population-wide level. As shown in the video highlights in Figure 2, combining MATL with TruFocus system enabled repeated imaging of multiple wells while maintaining sharp focus throughout the course of the 12 hour experiment.

Figure 2. XYZT multi-area time-lapse imaging of HUVECs expressing cytosolic GFP. Shown are 4 sample images of different positions with varying acquisition parameters. The TruFocus system was engaged to keep the sample in focus across the various fields of view throughout the course of the 13-hour experiment.

Imaging conditions

Top two panels:
Objective UPLXAPO20X
Microscope: FLUOVIEW FV3000RS laser scanning confocal microscope
Laser: 488nm (GFP, green)
Scanner: Resonant
Z series: 16 steps
Total number of areas scanned: 14

Bottom two panels:
Objective UPLXAPO10X
Microscope: FLUOVIEW FV3000RS laser scanning confocal microscope
Laser: 488nm (GFP, green)
Scanner: Resonant
Z series: 15 steps
Total number of areas scanned: 48

Total time of experiment: 13 hours and 11 minutes.

How the FV3000 Confocal Microscope Facilitated Our Experiment

Maintaining Focus during Multi-Area Time-Lapses with Olympus’ TruFocus Z-Drift Compensation System

The TruFocus Z-drift compensation (ZDC) system is a fully motorized module that combats focal drift to keep the sample in sharp focus during long-term, time-lapse experiments. The TruFocus system boosts application capabilities by supporting a large number of objectives and vessel types, including both glass- and plastic-bottomed dishes. This enables users to generate clear, focused, and continuous time-lapse data under multiple imaging conditions, without concern for Z-drift.

Multi-Area Time-Lapse (MATL) Software Module Enables Independent XYZT Parameters

The multi-area time-lapse (MATL) software module controls the FV3000 microscope’s motorized XY stage, permitting independent XYZT parameters for each registered position or tiled area. The MATL module provides robust and accurate time-lapse data through complete hardware integration and precise timing provided by the FV3000 inverted microscope, making the system well suited for imaging the numerous commercially available cover-glass bottom cultureware or even custom-made devices and microplates.

The multi-area time-lapse (MATL) software module controlling the FV3000 microscope’s motorized XY stage using independent XYZT parameters for each registered position or tiled area.
Dr James Hoying

Comment by Dr. James Hoying

We work with a variety of 3D vascularized tissue models arrayed across many wells of multi-well plates. The TruFocus system and MATL features of the FV3000 microscope have been invaluable as we often need to make measurements of vascularity and vessel morphology in dozens of tissues at a time using high-resolution, confocal images of the 3D vasculatures.

Acknowledgments

This application note was prepared with the help of the following researcher:
Dr. James Hoying, Chief Scientist, Advanced Solutions Life Sciences

FV5000

Confocal Laser Scanning Microscope

  • Extraordinary clarity, speed, and reliability driven by groundbreaking innovations
  • SilVIR™ detectors deliver photon-level quantitation, exceptional sensitivity, and ultra-high signal-to-noise
  • Unmatched dynamic range captures the full signal spectrum and prevents saturation
  • High-speed 2K resonant scanning and high-density 8K galvo scanning in one platform
  • FLUOVIEW Smart™ software simplifies operation with intuitive controls and AI-powered automation
  • TruResolution™ auto correction collar optimizes focus for over 20 objectives
  • Modular design supports up to 10 laser lines and future multiphoton upgrades
  • Laser Power Monitor (LPM) ensures stable illumination and reproducible results over time

Learn More

FV5000MPE

Multiphoton Laser Scanning Microscope

  • Compact fiber-pigtailed lasers enable deep, quantitative imaging in scattering tissue
  • One-, two-, or three-line simultaneous MPE laser excitation for millimeters deep imaging
  • SilVIR™, TruAI, and TruSight™ technologies deliver outstanding signal-to-noise and clarity
  • MPE-optimized objectives, TruResolution™ auto correction collar, and automated IR laser alignment maintain sharp focus
  • Available as an FV5000 system upgrade or a complete MPE system
  • Fully tunable laser configurations available for more advanced multiphoton applications

Learn More

FV4000

  • Game-changing dynamic range for imaging from the macro scale to subcellular structures
  • Multiplex up to six channels simultaneously with TruSpectral technology
  • Redesigned high-speed, high-resolution scanners for fixed and live cell imaging
  • Improved depth and photosensitivity with pioneering NIR capabilities and renowned optics
  • Peace of mind with the reliable, repeatable SilVIR detector
  • Industry leading * ten laser lines with a broader spectral range from 405 nm to 785 nm

*As of October 2023.

TruFocus (IX3-ZDC2)

  • Always in Focus
  • Designed for Ease-of-use
  • Dedicated to Live Cell Imaging
  • High-Precision, Multi-Area Imaging with cellSens Software