Automated Organoid Imaging and
High-Throughput 3D Analysis

Discover an imaging system that helps alleviate the burden from the operator, enabling rapid detection and automated sequential imaging of 3D objects.

Automated Macro-to-Micro Imaging

When imaging 3D specimens such as organoids or thick tissue samples, locating target objects can be a challenging and slow process. This task is especially time consuming in a multiple-chambered vessel or multiwell plates. Using this automated acquisition process, you can dramatically reduce the time you spend operating the microscope:

  1. The FV4000 confocal laser scanning microscope automatically captures images at low magnification.
  2. Then the FV software’s Macro-to-Micro module detects your objects of interest in the vessel or well and captures them at high magnification.

Automated Macro-to-Micro Imaging

Observation Condition For samples requiring 600 µm working distance or less For imaging samples in plastic-bottomed microplates For larger organoids requiring a WD greater than 600 µm
UPLXAPO20X UCPLFLN20XPH UPLSAPO30XS
UPLXAPO20X UCPLFLN20XPH UPLSAPO30XS
Numerical Aperture (NA) 0.8 0.7 1.05
Working Distance (WD) 600 μm 800 μm–1800 μm 800 μm
Field of View (FOV) 900 μm 900 μm 540 μm
Immersion Medium Air/Dry Air/Dry Silicone Oil
Refractive Index (RI) 1.0 1.0 1.4

Learn more about the importance of objective selection

High-Quality Images with X Line and A Line Objectives

Evident offers several objectives with features that help solve the challenges of organoid imaging conditions and observation requirements.

For organoids on a glass- or film-bottomed microplate, we recommend the UPLXAPO20X objective from the award-winning X Line™ series. This 20X objective provides an excellent balance of resolution, field of view, and depth of focus. It features a high NA of 0.8, a 600 µm working distance, and air immersion, which makes it easy to image across a microplate. For deep-tissue imaging applications, we recommend the UPLSAPO30XS 30X silicone oil immersion objective, which can reach up to 800 µm deep into your sample. Offering an impressive working distance range of 800 µm to 1800 µm, our UCPLFLN20XPH objective also enables imaging through plastic-bottomed vessels.

Seungil Kim, PhD, Microscopy Team Manager

“Automatic organoid imaging enables researchers to perform targeted imaging, which allows for fast detection and sequential high-magnification imaging of 3D objects. This ultimately contributes to the efficiency of our imaging workflow to examine phenotypic changes of patient-derived organoids in response to drug perturbations.”

Seungil Kim, PhD, Microscopy Team Manager
Lawrence J. Ellison Institute for Transformative Medicine of University of Southern California

Map at 4X

Map at 4X

Single slice at 20X

Single slice at 20X

Maximum intensity projection at 20X

Maximum intensity projection at 20X

FV5000

Confocal Laser Scanning Microscope

  • Extraordinary clarity, speed, and reliability driven by groundbreaking innovations
  • SilVIR™ detectors deliver photon-level quantitation, exceptional sensitivity, and ultra-high signal-to-noise
  • Unmatched dynamic range captures the full signal spectrum and prevents saturation
  • High-speed 2K resonant scanning and high-density 8K galvo scanning in one platform
  • FLUOVIEW Smart™ software simplifies operation with intuitive controls and AI-powered automation
  • TruResolution™ auto correction collar optimizes focus for over 20 objectives
  • Modular design supports up to 10 laser lines and future multiphoton upgrades
  • Laser Power Monitor (LPM) ensures stable illumination and reproducible results over time

Learn More

FV5000MPE

Multiphoton Laser Scanning Microscope

  • Compact fiber-pigtailed lasers enable deep, quantitative imaging in scattering tissue
  • One-, two-, or three-line simultaneous MPE laser excitation for millimeters deep imaging
  • SilVIR™, TruAI, and TruSight™ technologies deliver outstanding signal-to-noise and clarity
  • MPE-optimized objectives, TruResolution™ auto correction collar, and automated IR laser alignment maintain sharp focus
  • Available as an FV5000 system upgrade or a complete MPE system
  • Fully tunable laser configurations available for more advanced multiphoton applications

Learn More

FV4000
https://main--evident-website-eds--evidentscientific.aem.live/en/laser-scanning/fv4000/

FV4000

Confocal Laser Scanning Microscope

  • Game-changing dynamic range for imaging from the macro scale to subcellular structures
  • Multiplex up to six channels simultaneously with TruSpectral technology
  • Redesigned high-speed, high-resolution scanners for fixed and live cell imaging
  • Improved depth and photosensitivity with pioneering NIR capabilities and renowned optics
  • Peace of mind with the reliable, repeatable SilVIR detector
  • Industry leading* ten laser lines with a broader spectral range from 405 nm to 785 nm

*As of October 2023.

Learn More

FV4000MPE
https://main--evident-website-eds--evidentscientific.aem.live/en/laser-scanning/fv4000MPE/

FV4000MPE

Multiphoton Laser Scanning Microscope

  • Acquire accurate, quantitative image data from the macro scale to subcellular structures
  • Obtain more information from a single multicolor image
  • Monitor neuron and other essential dynamics with high-speed imaging

Learn More